New Transcatheter Mitral Valve Treatment

2011 ◽  
Vol 6 (1) ◽  
pp. 62
Author(s):  
Raquel del Valle-Fernández ◽  
Carlos E Ruiz ◽  
◽  

Percutaneous treatment of severe mitral regurgitation is a very interesting therapeutic option for those patients considered not to be suitable candidates for surgery. Different technologies have already demonstrated proof-of-concept, and one of these devices (the Mitraclip device) has already obtained the Conformité Europeéne mark. However, demonstrating safety and efficacy for most of these technologies is being harder than anticipated. Recently, research and development has become more compromised due to the financial crisis. This paper reviews the venues that are currently under evaluation.

Author(s):  
Arthur C. Hill ◽  
Michael D. Lesh ◽  
Alexander Khairkhahan

Objective A project is now underway to implement a novel percutaneous mitral repair system for severe mitral regurgitation (MR). The initial phase of the project consists of proof-of-concept by testing device characteristics using open surgical implantation. When surgical proof-of-concept of the intended percutaneous design is completed, a second phase of the project will consist of in vivo testing of the percutaneous transseptal system. The device is currently being designed to fold into a 17F catheter system and to unfold within the left atrium where attachment is accomplished using a reversible anchoring system. The purpose of this study was to show functionality of the device in elimination of MR using the open surgical method. Methods We have performed surgical prototype device implantation in 5 acute and 7 chronic sheep preparations. We created a P2-flail model of severe (4+) MR in the 12 sheep. Via a minimally invasive left thoracotomy incision and open repair on cardiopulmonary bypass, the device was implanted to determine efficacy of elimination of severe MR. Implantation was considered successful if 4+ regurgitation was converted to 1+ MR or lower. Left ventriculography and epicardial 2-dimensional/3-dimensional echocardiography were used to assess repair; serial 2-dimensional/3-dimensional transthoracic echocardiography was used to assess long-term mitral repair status. Results Twelve sheep had surgical creation of severe (4+) MR by cutting all chordae to the P2 scallop of the mitral valve; this preparation was tested and was found to produce 100% acute fatality without repair of the mitral valve. Five sheep had acute implantation of the device with elimination of regurgitation in 5/5 sheep. Seven sheep had chronic (1–7 month) implantation of the device. The device was tested in the chronic model for clinical status, residual regurgitation, thrombosis, and histopathology. All sheep had mitigation of MR and survived to the intended date of death. Conclusions Proof-of-concept of a novel percutaneous mitral repair device has been completed using an ovine P2-flail severe MR model. The device has characteristics that will allow its use in posterior leaflet degenerative disease and functional/secondary MR. Open, minimally invasive, and robotic surgical implantation of the device can also be developed as an alternative to the percutaneous approach.


2020 ◽  
Vol 7 ◽  
Author(s):  
Livia Gheorghe ◽  
Jorn Brouwer ◽  
Dee Dee Wang ◽  
Nina Wunderlich ◽  
Bushra Rana ◽  
...  

Mitral regurgitation is one of the most prevalent valvulopathies worldwide, and its surgical treatment is not feasible in all cases. The elderly and frail with several comorbidities and left ventricular dysfunction are often managed conservatively. Percutaneous treatment (repair or replacement) of the mitral valve has emerged as a potential option for those patients who are at a high risk for surgery. Mitral valve repair with the Mitraclip device proved both increased safety and mortality reduction in patients with severe mitral regurgitation. On the other hand, in the last decade, percutaneous mitral replacement opened new frontiers in the field of cardiac structural interventions. There are few mitral devices; some are in the early phase of development and some are waiting for CE mark of approval. The evolution of these devices was more complicated compared to the aortic technology due to the native mitral valve's complexity and access. This review aims to provide an overview of the current devices, their specific features, and their potential complications.


2012 ◽  
Vol 93 (6) ◽  
pp. e165
Author(s):  
Mohammad Q. Najib ◽  
Hari P. Chaliki ◽  
Satya S. Vittala ◽  
Amol Raizada ◽  
Roger L. Click

Sign in / Sign up

Export Citation Format

Share Document