scholarly journals Early Term Radiographic Follow-Up of the Trident Tritanium Acetabular Component

2021 ◽  
Vol 11 ◽  
Author(s):  
David DeBoer ◽  
Jeffrey Hodrick ◽  
Matthew Christie

INTRODUCTION: The purpose of this study was to evaluate the two year clinical and radiographic outcomes of patients undergoing a primary total hip arthroplasty (THA) using the Trident Tritanium primary Cup.   METHODS: 197 patients who underwent a direct anterior THA using a Tritanium acetabular component between 2011 and 2015 were retrospectively reviewed by two surgeons from a single institution. The investigators, along with an independent physician, separately reviewed radiographs blinded to clinical data looking for radiolucent lines adjacent to the acetabular cup using the Charnley-DeLee zones. Clinical results were measured using acetabular revision surgery as an end point for failure. According to the American Academy of Orthopaedic Surgeons Levels of Evidence, this study was consistent with a Level III Therapeutic study.   RESULTS: 101 (48.73%) subjects did not exhibit any radiolucent lines around the acetabular component. 53 (26.90%) subjects displayed radiolucency in only one zone. 27 (13.71%) subjects displayed radiolucency in two zones, and 16 (8.12%) displayed radiolucency in all three zones. Radiolucency was most prevalent in zone 1 at 2 years with 83 (42.13%) subjects displaying radiolucency. There were five (2.54%) acetabular failures within two years of the index surgery. Of those 5 subjects, 3 displayed radiolucency in 1 zone, 2 displayed radiolucency in >1 zone, and 2 displayed radiolucencies >1 mm.   CONCLUSION: In our study, the Tritanium Cup demonstrated a 2.54% failure rate for aseptic loosening at 2 year follow-up. In addition, 48.73% of patients displayed a radiolucent line in at least one Charnley-DeLee zone. We also observed a progression of radiolucencies between the 6 month radiographs and the 2 year radiographs.

2020 ◽  
Author(s):  
Arata Nakajima ◽  
Manabu Yamada ◽  
Masato Sonobe ◽  
Yorikazu Akatsu ◽  
Masahiko Saito ◽  
...  

Abstract Background: The FINE total knee was developed in Japan and clinical use began in 2001. It has unique design features, including an oblique 3o femorotibial joint line that reproduces anatomical geometry. Although 20 years have passed since the FINE knee was clinically used for the first time in Japan, a formal clinical evaluation including patient-reported and radiographic outcomes has not been undertaken.Methods: A total of 175 consecutive primary cruciate-retaining (CR)-FINE total knee arthroplasties (TKAs) at our hospital between February 2015 and March 2017 were included in this study. Three years postoperatively, range of motion (ROM), Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Forgotten Joint Score (FJS) were recorded and compared with preoperative scores. Radiographic analyses including mechanical alignment, component alignment, and incidence of radiolucent lines also were undertaken based on the radiographs three years postoperatively.Results: One-hundred twenty-two knees (70%) were available for 3-year follow-up data using KOOS, except for the sports subscale. Postoperative KOOS-symptom, -pain and -ADL were > 85 points, but KOOS-sports, -QOL and FJS were less satisfactory. ROM, KSS and all the subscales of KOOS were significantly improved compared with preoperative scores. Postoperative mean FJS was 66 and was significantly correlated with all the subscales of KOOS, but not with postoperative ROM. Radiolucent lines ≧1 mm wide were detected in five knees (4.1%). There were no major complications needing revision surgeries.Conclusions: Patient-reported outcomes (PROs) for symptoms, pain and ADL after the CR-FINE TKA were generally improved, but those for sports, QOL and FJS were improved less. The incidence of radiolucent lines was rare but detected around the femoral components. Improvements of surgical technique or innovation of the implant design with mid- to long-term follow-up will be necessary to achieve better PROs from patients receiving the FINE knee.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Arata Nakajima ◽  
Manabu Yamada ◽  
Masato Sonobe ◽  
Yorikazu Akatsu ◽  
Masahiko Saito ◽  
...  

Abstract Background The FINE total knee was developed in Japan and clinical use began in 2001. It has unique design features, including an oblique 3o femorotibial joint line that reproduces anatomical geometry. Although 20 years have passed since the FINE knee was clinically used for the first time in Japan, a formal clinical evaluation including patient-reported and radiographic outcomes has not been undertaken. Methods A total of 175 consecutive primary cruciate-retaining (CR)-FINE total knee arthroplasties (TKAs) at our hospital between February 2015 and March 2017 were included in this study. Three years postoperatively, range of motion (ROM), Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Forgotten Joint Score (FJS) were recorded and compared with preoperative scores. Radiographic analyses including mechanical alignment, component alignment, and incidence of radiolucent lines also were undertaken based on the radiographs 3 years postoperatively. Results One-hundred twenty-two knees (70%) were available for 3-year follow-up data using KOOS, except for the sports subscale. Postoperative KOOS-symptom, −pain and -ADL were > 85 points, but KOOS-sports, −QOL and FJS were less satisfactory. ROM, KSS and all the subscales of KOOS were significantly improved compared with preoperative scores. Postoperative mean FJS was 66 and was significantly correlated with all the subscales of KOOS, but not with postoperative ROM. Radiolucent lines ≧1 mm wide were detected in five knees (4.1%). There were no major complications needing revision surgeries. Conclusions Patient-reported outcomes (PROs) for symptoms, pain and ADL after the CR-FINE TKA were generally improved, but those for sports, QOL and FJS were improved less. The incidence of radiolucent lines was rare but detected around the femoral components. With the mid- to long-term follow-up, improvements of surgical technique will be necessary to achieve better PROs from patients receiving the FINE knee.


2021 ◽  
Vol 103-B (10) ◽  
pp. 1604-1610
Author(s):  
Yusuke Takaoka ◽  
Koji Goto ◽  
Jiro Tamura ◽  
Yaichiro Okuzu ◽  
Toshiyuki Kawai ◽  
...  

Aims We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610.


Children ◽  
2021 ◽  
Vol 8 (10) ◽  
pp. 858
Author(s):  
Giovanni Trisolino ◽  
Stefano Stallone ◽  
Francesco Castagnini ◽  
Barbara Bordini ◽  
Monica Cosentino ◽  
...  

Background: total hip replacement (THR) is a rare surgical option in children and adolescents with disabling hip diseases. The aim of this study is to report results from a retrospective cohort of patients aged 18 years or less who underwent cementless Ceramic-on-Ceramic (CoC) THR at a single institution, investigating clinical and radiographic outcomes, survival rates, and reasons for revision of the implants. Materials and methods: we queried the Registry of Prosthetic Orthopedic Implants (RIPO) to identify all children and adolescents undergoing THR between 2000 and 2019 at a single Institution. Inclusion criteria were patients undergoing cementless CoC THR, aged less than 18 years at surgery, followed for at least 2 years. Sixty-eight patients (74 hips) matched all the inclusion criteria and were enrolled in the study. We assessed the clinical and radiographic outcomes, the rate of complications, the survival rate, and reasons for revision of the implants. Results: The mean follow-up was 6.6 ± 4.4 years (range 2–20). The most frequent reason for THR was post-traumatic or chemotherapy-induced avascular necrosis (38%). The overall survival rate of the cohort was 97.6% (95% CI: 84.9–99.7%) at 5 years of follow-up, 94.4% (95% CI: 79.8–98.6%) at 10 years and 15 years of follow-up. Two THR in two patients (2.7%) required revision. With the numbers available, Cox regression analysis could not detect any significant interaction between preoperative or intraoperative variables and implant survivorship (p-value 0.242 to 0.989).” The average HOOS was 85 ± 14.3 (range 30.6–100). Overall, 23 patients (48%) reported excellent HOOS scores (>90 points), 21 patients (44%) reported acceptable HOOS scores (60–90 points) while 4 patients (8%) reported poor outcomes (<60 points). Twenty-one patients (43%) were regularly involved into moderate- to high-intensity sport activities (UCLA ≥ 6). Conclusions: Cementless CoC THR is a successful procedure in children and teenagers, having demonstrated high implant survivorship and low rates of complications and failure. A meticulous preoperative planning and implant selection is mandatory, to avoid implant malposition, which is the main reason of failure and revision in these cases. Further studies are needed to assess the impact of the THR on the psychosocial wellbeing of teenagers, as well as risks and benefits and cost-effectiveness in comparison to the hip preserving surgical procedures.


2018 ◽  
Vol 3 (4) ◽  
pp. 247301141879686
Author(s):  
Tood Borenstein ◽  
Tyler Gonzalez ◽  
Janet Krevolin ◽  
Bryan Den Hartog ◽  
David Thordarson

Background: Medial cuneiform dorsal opening wedge (Cotton) osteotomy is often used for treating forefoot varus in patients undergoing surgery for stage II posterior tibialis tendon dysfunction. The goal of this study was to examine the radiographic outcomes of Cotton osteotomy with bioactive glass wedge to assess for both maintenance of correction and clinical results and complications. We hypothesized that bioactive glass wedges would maintain correction of the osteotomy with low complication rates. Methods: Between December 2015 and June 2016, the charts of 17 patients (10 female and 7 male) who underwent Cotton osteotomy using bioactive glass wedges were retrospectively reviewed. Patient age averaged 56.8 years (range, 16-84). The average follow-up was 6.5 months. Radiographs were reviewed to assess for initial correction and maintenance of correction of medial column sag as well as for union. Charts were reviewed for complications. Results: The medial column sag correction averaged 15.6% on the final postoperative lateral radiograph. Meary angle averaged 19 degrees (3.14-42.8 degrees) preoperatively and 5.5 degrees (0.4-20.7 degrees) at final follow-up. All patients achieved clinical and radiographic union. One patient developed neuropathic midfoot pain and was managed with sympathetic blocks. One patient had a delayed union that healed at 6 months without surgical intervention. No patients required the use of custom orthotics or subsequent surgical procedures. Conclusion: Cotton osteotomy with bioactive glass wedges produced consistent correction of the medial column with low risk. Level of Evidence: Level IV, case series.


2018 ◽  
Vol 12 (2) ◽  
pp. 159-166 ◽  
Author(s):  
Murray Penner ◽  
W. Hodges Davis ◽  
Kevin Wing ◽  
Thomas Bemenderfer ◽  
Feras Waly ◽  
...  

Aims. This study presents the first report of clinical and radiographic outcomes of the Infinity Total Ankle System (Wright Medical, Memphis, TN) with minimum 2-year follow-up. Patients and Methods. The first 67 consecutive patients who underwent primary total ankle arthroplasty (TAA) with the Infinity system at 2 North American sites between August 2013 and May 2015 were reviewed in a prospective, observational study. Demographic, radiographic, and functional outcome data were collected preoperatively, at 6 to 12 months postoperatively, and annually thereafter. Results. The overall implant survival rate was 97% (65 of 67 implants) at a mean follow-up of 35.4 months (27 to 47 months). Two cases underwent talar component revision for aseptic loosening. Six of the 67 cases (9%) required a nonrevision reoperation. Mean Foot Function Index and Ankle Osteoarthritis Scale scores at latest follow-up improved from preoperative by 21.6 ( P < .0001) and 34.0 ( P < .0001), respectively. No radiographic loosening of any talar or tibial components was identified in the 65 nonrevised cases. Conclusion. Early clinical and radiographic outcomes with the Infinity TAA are promising and compare favorably to those reported for both fixed- and mobile-bearing third-generation TAA designs, even when used in cases with deformity and increased case complexity. Levels of Evidence: Level IV


2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0038
Author(s):  
Murray Penner ◽  
W. Hodges Davis ◽  
Thomas Bemenderfer ◽  
Feras Waly ◽  
Robert Anderson

Category: Ankle Arthritis Introduction/Purpose: Background: Increasing interest in 2-component total ankle arthroplasty (TAA) designs and the increased use of TAA overall has led to the development of a new generation of 2-component TAA implants. The first of these to become available was the Infinity Total Ankle System (Wright Medical Technology, Memphis, TN), introduced in 2014. Despite it currently being the most commonly used TAA implant in the UK and among the most commonly used in the USA, published clinical results are lacking. Purpose: This study presents the first report of the clinical and radiographic outcomes of the Infinity Total Ankle System with minimum 2 year follow-up Methods: The first 67 consecutive patients who underwent primary Infinity total ankle arthroplasty (TAA) at 2 North American sites between 2013 and 2015 were reviewed in a prospective observational study. Demographic, radiographic, and functional outcome data was collected preoperatively, at 6-12 months postoperatively, and annually thereafter. Results: The overall implant survival rate was 97% (65 of 67 implants) at mean follow up of 3 years (range 27-47 months). Two cases underwent talar component revision for aseptic loosening. Six of the 67 cases (9%) required a non-revision reoperation. Mean FFI and AOS scores at latest follow up improved from preoperative by 21.6 (p<0.0001) and 34.0 (p<0.0001), respectively. No radiographic loosening of any talar or tibial components was identified in the 65 non-revised cases. Conclusion: Early clinical and radiographic outcomes with the Infinity TAA are promising and compare favorably to those reported for both fixed- and mobile-bearing third generation TAA designs, even when used in cases with deformity and increased case complexity.


2018 ◽  
Vol 11 (02) ◽  
pp. 071-079 ◽  
Author(s):  
Hannah M. Carl ◽  
Scott D. Lifchez

Abstract Background Deterioration of the distal radioulnar joint (DRUJ) in rheumatoid arthritis (RA) manifests as pain, weakness, and reduced range of motion. The Darrach and Sauvé-Kapandji (S-K) procedures are used when medical management fails to control these symptoms. However, there is a paucity of literature comparing the outcomes of these procedures. The purpose of this study is to compare the clinical and radiographic outcomes of the Darrach and S-K procedures in RA patients. Materials and Methods This is a retrospective, single institution cohort study of RA patients who underwent the Darrach or S-K procedure between 2008 and 2016. Ulnar translation, range of motion, and functional improvement were compared. Results Nine patients (13 wrists) underwent the Darrach procedure, and nine patients (11 wrists) underwent the S-K procedure. The average length of follow-up was 1.3 years. Pain, function, and range of motion improved in both groups. The degree of ulnar translation did not significantly change after either procedure. Conclusion Given their similar outcomes, we found no evidence that the S-K procedure is superior to the Darrach procedure or vice versa. However, when surgery is indicated for younger RA patients with DRUJ disease and ulnar translation, the S-K may be better suited to prevent radiocarpal joint dislocation.


Stroke ◽  
2020 ◽  
Vol 51 (Suppl_1) ◽  
Author(s):  
Yung Ki Park ◽  
Hae-Won Koo

Introduction: Cerebral arteriovenous malformation (AVM) is an intracranial pial vascular lesion which is treated with microsurgery, endovascular treatment or stereotactic radiosurgery (SRS). We introduce the long-term clinical results of linear accelerator (LINAC) stereotactic radiosurgery for cerebral AVM which is treated in single institution for 18 years period. Methods: Retrospective chart review was held in cerebral AVM patients treated with Novalis (BrainLAB AG, Heimstetten, Germany) stereotactic radiotherapy from 2001 to 2018. Clinical results such as obliteration rate, hemorrhage rate after SRS, and radiosurgery related adverse event was analyzed. Furthermore, predictors for obliteration and symptomatic radiosurgery induced adverse event was analyzed with multivariate logistic regression test. Results: Among 117 patients with cerebral AVMs treated with LINAC-based SRS, 72 were included in study. Total obliteration rate was 80.6% (58/72) for mean 57.0±48.3 months follow up period. Post-SRS hemorrhage and mortality rate was 6.9% (4/72) and 1.4% (1/72), respectively. Mean radiation dose and volume was 22.8Gy and 3.7cc, respectively. Independent predictive factors for nidus obliteration was: (1) radiation dose (OR 1.43, 95% CI 1.04-2.08, p=0.0374), (2) Ruptured AVM (OR 12.18, 95% CI 2.38-86.47, p=0.0054), (3) Virginia AVM score (OR 0.21, 95% CI 0.07-0.53, p=0.0028), and (4) follow up period months (OR 1.03, 95% CI 1.01-1.06, p=0.0261). Independent risk factors for symptomatic radiosurgery related adverse event was radiation volume (OR 1.61, 95% CI 1.09-2.65, p=0.0326). Conclusion: LINAC-based SRS is effective and relatively safe method for treatment of cerebral AVMs. Independent predictive factors for obliteration was high radiation dosage, ruptured status, low Virginia AVM score, and long follow up period. High radiation volume was related to symptomatic radiation induced adverse event.


2013 ◽  
Vol 26 (05) ◽  
pp. 408-415 ◽  
Author(s):  
L. Vezzoni ◽  
V. Montinaro ◽  
A. Vezzoni

SummaryLoosening of the acetabular cup is one of the most common complications following total hip replacement and has an incidence rate of 1.8% to 36.8%. The objective of this study was to describe the surgical technique for the application of a cementless acetabular component specifically designed for treatment of cup loosening and preliminary clinical experience. The Kyon revision cup is composed of two components; the first is a perforated titanium outer shell with holes for 2.4 mm titanium screws, which is impacted into the acetabulum after removal of the loose cup and reaming of the acetabulum. It is secured with a variable number of screws. The second component is an inner plain titanium cup with an ultra-high-molecular-weight polyethylene insert, which is impacted into the outer shell to obtain press-fit stability. This revision cup was used in 31 dogs with cup loosening and a minimum follow-up period of six months. There were four intra-operative complications and two postoperative complications. The main intra-operative complication was difficulty inserting the inner cup into the outer shell. Postoperative complications included craniodorsal hip luxation in one dog, which was successfully managed, and cup loosening in another dog, which required explantation of the prosthesis. The main advantage of the revision cup appears to be increased implant stability afforded by screw fixation. Our initial clinical results in 31 dogs were promising; all but one dog had a successful clinical outcome.


Sign in / Sign up

Export Citation Format

Share Document