A validated densitometric TLC method for analysis of cefuroxime axetil and potassium clavulanate in combined tablet dosage forms

2010 ◽  
Vol 22 (1) ◽  
pp. 91-97 ◽  
Author(s):  
M. R. Sengar ◽  
S. V. Gandhi ◽  
U. P. Patil ◽  
V. S. Rajmane ◽  
K. G. Bothara
2018 ◽  
Vol 15 (2) ◽  
pp. 6282-6295
Author(s):  
Abdul Aziz Ramadan ◽  
Marwa Bakdash

A simple, direct and cost-effective spectrophotometric method for determination of cefuroxime axetil (CRXA)  in pure and tablet dosage forms was applied. This method is based on formation of ion-pair complex ([CRXA]:[BTB]) between CRXA and bromothymol blue (BTB) in chloroform. Beer’s law in the optimum experimental conditions using [CRXA]:[BTB] complex is valid within a concentration range of 2.00-50.00 ?M (1.021–25.524 ?g.mL-1). The developed method is applied for the determination of CRXA in pure and its commercial tablets without any interference from excipients with average assay of 96.8 to 101.6% and the results are in good agreement with those obtained by the HPLC reference method. Associated drugs (sulbactam and linesolid) with cefuroxime axetil are considered to be interfere, while metronidazole can be considered as non-interfere.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
J. Saroja ◽  
Anantha Lakshmi P.V. ◽  
Y. Rammohan ◽  
D. Divya Reddy

Abstract Background We describe a “stability-indicating liquid chromatography” technique for the estimation of dimethicone (DEC) and dicyclomine hydrochloride (DEH) in the established tablet formulations. Individual quantification of DEH and DEC was reported. But simultaneous quantification of DEH and DEC was lacking. DEH and DEC were analysed on an “XTerra C18 column (250 mm × 4.6 mm, 5 μm)” with the mobile phase solvent run isocratically with 0.1M K2HPO4-acetonitrile (55:45, v/v) on a flow speed of 1.0 mL/min. Results The chromatographic run period for the DEC and DEH assay was 6.0 min with retention times of 2.134 and 2.865 min, respectively. The method was validated for accuracy (99.453 to 100.417% and 99.703 to 100.303% recovery values for DEH and DEC, respectively), precision (RSV value 0.135% for DEC and 0.171% for DEH), linearity (5–15 μg/mL for DEH and 20–60 μg/mL for DEC), selectivity (no hinderance from excipients) and specificity (no hinderance from degradants) recovery. Conclusion The developed stability-indicating liquid chromatography process was well applied to established tablet formulations.


2013 ◽  
Vol 25 (8) ◽  
pp. 4788-4790
Author(s):  
T. Vijaya Bhaskara Reddy ◽  
G. Ramu ◽  
M. Sravan Kumar ◽  
C. Rambabu

Sign in / Sign up

Export Citation Format

Share Document