Carrier Lifetime Measurements by Photoconductance at Low Temperature on Passivated Crystalline Silicon Wafers

2013 ◽  
Vol 1536 ◽  
pp. 119-125 ◽  
Author(s):  
Guillaume Courtois ◽  
Bastien Bruneau ◽  
Igor P. Sobkowicz ◽  
Antoine Salomon ◽  
Pere Roca i Cabarrocas

ABSTRACTWe propose an implementation of the PCD technique to minority carrier effective lifetime assessment in crystalline silicon at 77K. We focus here on (n)-type, FZ, polished wafers passivated by a-Si:H deposited by PECVD at 200°C. The samples were immersed into liquid N2 contained in a beaker placed on a Sinton lifetime tester. Prior to be converted into lifetimes, data were corrected for the height shift induced by the beaker. One issue lied in obtaining the sum of carrier mobilities at 77K. From dark conductance measurements performed on the lifetime tester, we extracted an electron mobility of 1.1x104 cm².V-1.s-1 at 77K, the doping density being independently calculated in order to account for the freezing effect of dopants. This way, we could obtain lifetime curves with respect to the carrier density. Effective lifetimes obtained at 77K proved to be significantly lower than at RT and not to depend upon the doping of the a-Si:H layers. We were also able to experimentally verify the expected rise in the implied Voc, which, on symmetrically passivated wafers, went up from 0.72V at RT to 1.04V at 77K under 1 sun equivalent illumination.

1999 ◽  
Vol 70 (10) ◽  
pp. 4044-4046 ◽  
Author(s):  
J. Gervais ◽  
O. Palais ◽  
L. Clerc ◽  
S. Martinuzzi

Materials ◽  
2019 ◽  
Vol 12 (1) ◽  
pp. 190 ◽  
Author(s):  
Christian Bscheid ◽  
Christian R. Engst ◽  
Ignaz Eisele ◽  
Christoph Kutter

Contactless minority carrier lifetime (lifetime) measurements by means of microwave detected photoconductivity are employed for oxidation process characterization and furnace profiling. Characterization is performed on oxidized float zone substrates with high resistivity and outstanding bulk quality, suggesting that the measured effective lifetime is strongly dominated by interface recombination and therefore reflects the oxide quality. The applied approach requires neither test structures nor time consuming measurements and is therefore of particular interest if high throughput is required. The method is used to investigate the impact of oxidation furnace leakage as well as to analyze the oxidation homogeneity across a horizontal oxidation furnace. For comparison, capacitance-voltage measurements are conducted to characterize the oxide properties. It is found that any type of furnace leakage, which induces fixed oxide charges as well as interface states, has a heavy impact on the measured effective lifetime, especially on the shape of generation rate dependent lifetime curves. Furthermore, a distinct lifetime decrease towards the tube door of the oxidation furnace could be observed. The latter is even detectable in an ideal oxidation process, generating high quality oxides. Besides plain equipment characterization, the presented approach is suitable to optimize the oxidation process itself regarding different parameters like temperature, gas flow, pressure, or process time.


2012 ◽  
Vol 112 (5) ◽  
pp. 054508 ◽  
Author(s):  
Fa-Jun Ma ◽  
Ganesh G. Samudra ◽  
Marius Peters ◽  
Armin G. Aberle ◽  
Florian Werner ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document