Hardness as a Measure of Wear Resistance

1983 ◽  
Vol 27 ◽  
Author(s):  
W.C. Oliver ◽  
R. Hutchings ◽  
J.B. Pethica ◽  
I.L. Singer ◽  
G.K. Hubler

ABSTRACTOne measure of the surface mechanical properties of materials can be obtained through microhardness data. The success of microhardness in predicting the improvements in wear resistance of ion implanted metals has been mixed. In this paper the cases of N implantation into 304 S.S. and Ti implantation into 52100 bearing steel will be examined. Microhardness data indicates little or no hardness changes whereas large wear rate changes are observed. From these two examples it is clear that the wear mechanism, the chemical nature of the surface, the ductility, and the toughness can be more important than the hardness changes.

2020 ◽  
Vol 10 (20) ◽  
pp. 7363
Author(s):  
Lei Xu ◽  
Erkuo Yang ◽  
Yasong Wang ◽  
Changyun Li ◽  
Zhiru Chen ◽  
...  

Ultra high-pressure sintering (UHPS) was used to prepare AA6061/SiCp composites with different contents and the effect of sintering temperatures on microstructure and mechanical properties was investigated in this study. The results showed that a uniform distribution of nano-SiC particles (N-SiCp) is obtained by the UHPS method. With the increase in N-SiCp contents, the higher hardness and better wear resistance could be inspected. The interfacial reactions and Al4C3 phase appeared above 550 °C. The relative density of composites first increased and then decreased; with the temperature raising it reached 99.58% at 600 °C. The hardness and wear property showed the same trend with the hardness reaching 52 HRA and wear rate being 1.0 × 10−6 g/m at 600 °C. Besides, the wear mechanism of the composites is mainly composed of abrasive wear and adhesive wear.


2020 ◽  
pp. 58-63
Author(s):  
M.A. Druzhinin ◽  
◽  
G.V. Okromelidze ◽  
O.V. Garshina ◽  
I.A. Kudimov ◽  
...  

Author(s):  
Fathima Banu Raza ◽  
Anand Kumar

The o-rings in ball retained overdentures deteriorate with time and need replacement to restore the retentive quality. We evaluated retrospectively the mechanical properties of o-rings after 3 years in function in one and two-piece implant-supported overdentures. The o-rings were retrieved from one-piece (Myriad snap, Equinox-Straumann, 3.3 x 13mm) and two-piece (Neo Biotech, 3.3 x 13mm) implant-supported overdenture patients. A total of 16 pairs of matrices were tested for wear, type of damage and elasticity using Pin on Disc method, USB Digital Camera in 30x zoom and Universal Tensile Machine respectively. The statistical analysis for independent groups were done with the Mann-Whitney U test. Assessment of used O-rings showed 84% more wear in the two-piece system with an abrasive type of damage while 46% wear in the one-piece system with a compressive type of damage. The o-rings in one-piece system showed increase in elongation and maximum displacement to 2% and 7% respectively, while two-piece system showed decrease in elongation and maximum displacement by 13% and 6% respectively. In one-piece system, the loss of retention was more with slow wear rate and in two-piece system, the wear resistance of O-rings decreased due to increased stiffness. Further studies to evaluate the changes in O-ring with increased sample size and at interval 1 year will pave way for insight into the progressive changes in the mechanical properties of an O-ring.