Optimal characteristics of ground heat exchangers for heat pump heating systems

2016 ◽  
Vol 0 (1) ◽  
Author(s):  
Mykhailo K. Bezrodnyi ◽  
Natalia О. Prytula
Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1853 ◽  
Author(s):  
Pavel Neuberger ◽  
Radomír Adamovský

The efficiency of a heat pump energy system is significantly influenced by its low-temperature heat source. This paper presents the results of operational monitoring, analysis and comparison of heat transfer fluid temperatures, outputs and extracted energies at the most widely used low temperature heat sources within 218 days of a heating period. The monitoring involved horizontal ground heat exchangers (HGHEs) of linear and Slinky type, vertical ground heat exchangers (VGHEs) with single and double U-tube exchanger as well as the ambient air. The results of the verification indicated that it was not possible to specify clearly the most advantageous low-temperature heat source that meets the requirements of the efficiency of the heat pump operation. The highest average heat transfer fluid temperatures were achieved at linear HGHE (8.13 ± 4.50 °C) and double U-tube VGHE (8.13 ± 3.12 °C). The highest average specific heat output 59.97 ± 41.80 W/m2 and specific energy extracted from the ground mass 2723.40 ± 1785.58 kJ/m2·day were recorded at single U-tube VGHE. The lowest thermal resistance value of 0.07 K·m2/W, specifying the efficiency of the heat transfer process between the ground mass and the heat transfer fluid, was monitored at linear HGHE. The use of ambient air as a low-temperature heat pump source was considered to be the least advantageous in terms of its temperature parameters.


2014 ◽  
Vol 580-583 ◽  
pp. 2457-2460
Author(s):  
Zi Shu Qi ◽  
Qing Gao ◽  
Yan Liu ◽  
Zhen Hai Gao ◽  
Li Bai

The heat pump system by using earth energy is increasing very rapidly. In this paper, by studying the underground heat exchanger heat transfer mode, the computing platform for ground source heat pump system was established. Through a engineering case, the influence character of the circulation flow velocity in ground heat exchangers on the fluid temperature, the heat pump power consumption, and the length of system were analyzed, which provide an approach for system engineering design and operation prediction, and for the thermodynamic analysis of performance of system year by year and prospective study to guide the engineering practice.


2018 ◽  
Vol 44 ◽  
pp. 00157
Author(s):  
Piotr Rynkowski

The paper presents the ground temperature analysis, heat flows and energy transferred from the soil massif by the vertical ground heat exchangers (VGHE). Three cases – with one, two and three vertical heat exchangers were compared. Their influences on the soil massif temperature in the heat exchangers area were shown. The mass flow and the temperature at the inlet and outlet side of the heat pump were measured in each circuit. Additional, the electricity consumption by the heat pump and energy supply to buffer vessel were measured. Finally, the Coefficient of Performance (COP) as a function of length of VGHE is shown for selected interval time.


2014 ◽  
Vol 548-549 ◽  
pp. 595-600
Author(s):  
Can Can Zhang ◽  
Yue Jin Yu

In order to analyze the influence of groundwater flow on ground heat exchangers with different arrangements, with a project in Nanjing the access temperature field in the multi-borehole field was simulated after the ground source heat pump system had been performed for a year. Simulation results show that the access temperature is higher in the ground surrounding the borehole than the center of the corresponding borehole, thus forming a thermal barrier surrounding the borehole. Groundwater flow helps relieve temperature imbalance owing to the imbalance of heating and cooling load. The performance of the ground heat exchangers is better in staggered arrangement than in aligned arrangement. In the borehole field, the boreholes upstream have thermal interference on those downstream. And the extent of thermal interference depends on the direction of the groundwater flow when the locations of the boreholes are fixed in the borehole field.