Marginal Fit of Implant-Supported All-Ceramic Zirconia Frameworks

2013 ◽  
Vol 39 (4) ◽  
pp. 417-424 ◽  
Author(s):  
Hanaa Hassan Zaghloul ◽  
Jihan Farouk Younis

This study evaluated the effect of fabrication techniques and cyclic loading on the vertical marginal fit of implant-supported fixed partial denture (FPD) frameworks. Thirty implant-supported 3-unit FPD frameworks were fabricated on a model system, divided into 3 equal groups (n = 10). The first group (control) was constructed from base metal alloy; the other 2 test groups were constructed from all-ceramic zirconia using a computer-aided design/computer-aided manufacturing (CAD/CAM) Cerec 3 system and a copy milling (Zirkonzahn) system. A cyclic load of 200 N was applied to each framework for up to 50,000 cycles. Linear measurements were made in micrometers of the vertical gap between the framework and the implant-supported abutment at 16 predetermined points before and after cyclic loading. The frameworks were viewed using scanning electron microscopy to inspect any fractographic features. One-way analysis of variance was performed to compare the marginal discrepancy values of the control and the 2 test groups and for each group; a t test was applied to determine whether significant changes in the fit were observed after cyclic loading (α = 0.05). The CAD/CAM group showed significantly higher marginal gap mean values (80.58 μm) than the Zirkonzahn and control groups (50.33 μm and 42.27 μm, respectively) with no significant difference. After cyclic loading, the CAD/CAM group recorded the highest marginal gap mean value (91.50 ± 4.260 μm) followed by control group (72.00 ± 2.795 μm); the Zirkonzahn group recorded the lowest marginal gap (65.37 ± 6.138 μm). Cyclic loading significantly increased the marginal gap mean values in the control group only. A marginal chip was observed in one of the CAD/CAM ceramic frameworks. Within the limitations of this study, the fabrication technique influenced the marginal fit of the implant-supported 3-unit FPD frameworks. Cyclic loading failed to change the fit of all-ceramic zirconia frameworks, whereas significant changes were found in the metal frameworks.

Folia Medica ◽  
2020 ◽  
Vol 62 (3) ◽  
pp. 546-552
Author(s):  
Aleksandra Pecheva ◽  
Kostadin Georgiev ◽  
Snezhana Tsanova ◽  
Ralitsa Raycheva

Introduction: One method to evaluate the clinical success of cemented restorations is measuring the marginal adaptation. There is a correlation between the fitting of the restoration and problems caused by clinically undetectable passage of bacteria between the tooth structure and the veneer. Aim: To evaluate in comparison the marginal adaptation of veneers produced via CAD/CAM and press technique. Materials and methods: 32 extracted incisors are divided into two equal-number groups (n=16) according to the production technique – CAD/CAM zirconium veneers and press-ceramic veneers. Cut sections are examined under a SEM magnification. Marginal accuracy is measured as the distance between the finish line of the tooth and the margin of the veneer at eight fixed locations. Results: The mean values of marginal gap of group 1 are: external adaptation – 79.88±3.71 µm; internal adaptation – 79.14±15.70 µm; cervical adaptation – 82.39±28.55 µm; incisal adaptation – 86.85±21.72 µm. The mean values of marginal gap of group 2 are: external adaptation – 100.31±2.16 µm; for internal adaptation – 101.01±12.51 µm; cervical adaptation – 91.55±3.31 µm; incisal adaptation – 93.76±2.54 µm. Conclusions: Veneers produced via CAD/CAM technology have better fit at the external and internal marginal wall. There is no statistically significant difference between the gaps at the cervical and the incisal areas.


2021 ◽  
Author(s):  
CA Jurado ◽  
A Tsujimoto ◽  
H Watanabe ◽  
NG Fischer ◽  
JA Hasslen ◽  
...  

SUMMARY Objective: The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. Method: Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All- Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. Results: All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. Conclusions: Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.


2018 ◽  
Vol 43 (4) ◽  
pp. 437-446 ◽  
Author(s):  
NG Fischer ◽  
A Tsujimoto ◽  
AG Baruth

SUMMARY Objective: Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. Purpose: To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. Methods: One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. Results: AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. Conclusions: These in vitro results suggest changes in OP Ra due to bur reuse and polishing application force. Within the parameters of this study, the resultant topography of zirconia polishing is force-dependent and the reuse of coarse polishing burs is possible without statistically significant differences in Ra values after initial use. Nanoscale and microscale topography were shown to depend on specific polishing bur type.


2019 ◽  
Vol 17 (1) ◽  
pp. 228080001880710 ◽  
Author(s):  
İbrahim Duran ◽  
Necati Kaleli ◽  
Çağrı Ural ◽  
İdris Kavut

Background: This in vitro study aimed to evaluate the amount of polymerizing light passing through hybrid ceramic specimens in different shades and thicknesses. Methods: Rectangular-shaped feldspathic ceramic computer aided design and computer aided manufacturing (CAD-CAM) blocks and translucent and high translucent polymer infiltrated hybrid ceramic CAD-CAM blocks in four different shades (1M1, 1M2, 2M2, and 3M2) were sectioned in four different thicknesses (0.8, 1.5, 2, and 3 mm), and a total of 48 groups ( n = 10) were obtained. Feldspathic ceramic specimens served as the control group. The light transmission of each ceramic specimen was measured three times by using a light-emitting diode and a radiometer. Data were statistically analyzed by using univariate analysis of variance (ANOVA) followed by one-way ANOVA, Tukey honest significant difference, and Tamhane T2 tests (α = 0.05). Results: Translucent polymer infiltrated hybrid ceramic specimens exhibited significantly ( p < 0.001) lower light transmission values than high translucent polymer infiltrated hybrid ceramic and feldspathic ceramic specimens, whereas feldspathic ceramic specimens exhibited significantly ( p < 0.001) higher light transmission than translucent and high translucent polymer infiltrated hybrid ceramic specimens. The amount of light transmission significantly ( p < 0.05) decreased when the shade value decreased and the thickness increased. Conclusions: Polymer infiltrated hybrid ceramic specimens showed lower light transmission values than feldspathic ceramic specimens, and the amount of light transmission was affected by the ceramic shade and thickness.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Ki-Hong Lee ◽  
In-Sung Yeo ◽  
Benjamin M. Wu ◽  
Jae-Ho Yang ◽  
Jung-Suk Han ◽  
...  

Purpose. The purpose of this study was to investigate the marginal fit of metal-free crowns made by three different computer-aided design/computer-aided manufacturing (CAD/CAM) systems.Materials and Methods. The maxillary left first premolar of a dentiform was prepared for all-ceramic crown restoration. Thirty all-ceramic premolar crowns were made, ten each manufactured by the Lava system, Cercon, and Cerec. Ten metal ceramic gold (MCG) crowns served as control. The marginal gap of each sample was measured under a stereoscopic microscope at 75x magnification after cementation. One-way ANOVA and the Duncan’s post hoc test were used for data analysis at the significance level of 0.05.Results. The mean (standard deviation) marginal gaps were 70.5 (34.4) μm for the MCG crowns, 87.2 (22.8) μm for Lava, 58.5 (17.6) μm for Cercon, and 72.3 (30.8) μm for Cerec. There were no significant differences in the marginal fit among the groups except that the Cercon crowns had significantly smaller marginal gaps than the Lava crowns(P<0.001).  Conclusions. Within the limitation of this study, all the metal-free restorations made by the digital CAD/CAM systems had clinically acceptable marginal accuracy.


2019 ◽  
Vol 13 (01) ◽  
pp. 017-021
Author(s):  
Nor Faharina Abdul Hamid ◽  
Wan Zaripah Wan Bakar ◽  
Zaihan Ariffin

Abstract Objective This study was carried out to assess and compare the marginal gap of conventionally used metal onlays and new resin nanoceramic (RNC) (Lava Ultimate block) onlays. Materials and Methods This is an in vitro study using two extracted sound human mandibular molars. One tooth was prepared to receive the metal onlays and another one for the RNC onlays which were fabricated using the computer-aided design and computer-aided manufacturing (CAD/CAM) technology. Twelve metals and 12 ceramic onlays were fabricated before they were placed at their respective preparation and examined under the Leica stereomicroscope, M125C (Leica Microsystems, Wetzlar, Germany) for a marginal analysis. The gap width was measured at 10 predefined landmarks which included 3 points on the buccal and lingual surfaces each and 2 points each on the mesial and distal surfaces, respectively. Statistical Analysis Mann–Whitney post hoc test was used for statistical analysis (P ≤ 0.05). Results Overall, the RNC onlays showed significant lower marginal gap with the exception of the landmarks 5 and 6 (on distolingual) and no significant difference at landmark 7 (on midlingual). It was observed that the marginal gap were all within the clinically acceptable limit of 120 μm. Conclusions Based on the results obtained, it can be concluded that the RNC CAD/CAM onlays are a promising alternative to the metal onlays.


2017 ◽  
Vol 11 (03) ◽  
pp. 330-334 ◽  
Author(s):  
Marwa I. Elagra ◽  
Mohammad R. Rayyan ◽  
Maisam M. Alhomaidhi ◽  
Areej A. Alanaziy ◽  
Mona O. Alnefaie

ABSTRACT Objective: Many commercial dental materials are used to fabricate interim restorations. This study aimed to compare the color stability and the marginal integrity of four different interim crown materials. Materials and Methods: An ivorine right maxillary central incisor was prepared for a full coverage all-ceramic restoration. A total of 36 specimens in the form of crowns were fabricated on the master die using four different materials (n = 9); Polymethyl methacrylate (PMMA) resin (TrimPLUS), PMMA computer-aided design, and computer-aided manufacturing (CAD-CAM) blocks (Ceramill TEMP), cold cure bis-acryl resin (Success CD), and bis-acryl resin dual-cure composite (TempSpan). Color change ΔE for each sample was calculated by measuring its color as Commission Internationale de l'Eclairage L* a* b* with a spectrophotometer before and after immersing in a concentrated tea solution for 7 days. Marginal gap was measured at four reference points using stereomicroscope at ×40. One-way ANOVA and the Tukey multiple comparisons test were used to determine any statistically significant difference between the four groups, (α = 0.05). Results: Success CD showed significantly the greatest color change (7.7) among all the tested materials, while no significant difference was found between the other three materials. TempSpan showed significantly the highest marginal gap formation (430.15 μm), while no significant difference was found between the three other materials. Conclusions: Bis-acryl resin composite materials demonstrated clinically noticeable change in color while PMMA materials demonstrated superior color stability. Dual cure interim materials exhibited significantly higher marginal discrepancy in comparison to PMMA and cold cure bis-acrylic resin materials. CAD-CAM PMMA material exhibited the best color stability and marginal integrity.


2020 ◽  
Vol 19 ◽  
pp. e200537
Author(s):  
Roniel Kapler ◽  
Michelle Villa Oliveira ◽  
Ingrid de Oliveira Bandeira ◽  
Thayara Coelho Metzker ◽  
Adriana Oliveira Carvalho ◽  
...  

Aim: The aim of this study was to evaluate the marginal adaptation of ceramic and composite resin crowns fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) technology using an intraoral digital scanner. Methods: A human mandibular right second molar was prepared for a ceramic crown. The impressions were made using intraoral scanning device and crowns were milled. Tem crowns were fabricated for each group (n=10): GF – Feldspathic Ceramic (Cerec Blocs, Sirona), GL - Lithium Disilicate Ceramic (IPS e.max CAD, Ivoclar), GG - composite resin (Grandio Blocs, VOCO) and GB - composite resin (Brava Block, FGM). The marginal gap was measured for each specimen at 4 points under magnification with a stereomicroscope. All data were statistically analyzed using one-way ANOVA followed by the Tukey’s test (α=.05). Results: The lowest marginal discrepancy value was observed in GB (60.95 ± 13.64 μm), which was statistically different from the GL (84.22 ± 20.86 μm). However, there was no statistically significant difference between these groups when compared with the other groups, GF (73.26 ±8.19 μm) and GG (68.42 ± 11.31 μm). Conclusion: It can be concluded that the composite resin presented the lowest variance compared to the lithium disilicate glass ceramic, although the marginal gap of all materials tested was within the acceptable clinical limit (120 μm).


2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


Author(s):  
Abdulrahman Alhaddad ◽  
Samar Abuzinadah ◽  
Abdullah Al-Otaibi ◽  
Abrar Alotaibi ◽  
Mohsen Alfkih ◽  
...  

Background: Zirconia-based restorations have become more popular in dentistry during the last two decades. Patients choose metal-free restorations, preferring materials with similar attributes to natural teeth and similar light scattering characteristics, resulting in a nice esthetic appearance. Restoring a root canal treated teeth is one of the hot topics today. endo crown materials can be either; feldspathic, glass-ceramic, monolithic hybrid ceramic or composite material. Considering the marginal gap of endocrown, an important cause of failure of treatment, the current study evaluated the marginal gap of CAD‐CAM concocted endo-crowns. Materials and Methods: This research is an analysis systemic review study was conducted between January 2020 and October 2021. We followed the PRISMA principles and recorded this systematic review using the PROSPERO database to find and identify published literature related to the marginal adaptation of CAD-CAM-fabricated endocrown. The search will include all relevant articles through the end of 2021. Finally, 24 papers on marginal clearance and fracture resistance in coronary arteries were reviewed. Results: The electronic database search yielded 98 studies that were relevant. After cross-referencing, further seven studies were added. After a full-text analysis and duplicate reduction, 74 of the 98 articles were eliminated. 5 clinical (prospective) studies, 19 in vitro studies were found. Conclusion: This analysis of the recent literature on the marginal seating integrity and fracture resistance of CAD/CAM made-up endo-crowns showed that the endo-crown had superior marginal seating integrity than classical full crown. CAM/CAM showed statistically significant higher mean fracture resistance than MAD/MAM.