scholarly journals Fracture resistance of weakened roots restored with composite resin and glass fiber post

2008 ◽  
Vol 19 (4) ◽  
pp. 329-333 ◽  
Author(s):  
Lucas Villaça Zogheib ◽  
Jefferson Ricardo Pereira ◽  
Accácio Lins do Valle ◽  
Jonas Alves de Oliveira ◽  
Luiz Fernando Pegoraro

This study evaluated the fracture resistance of weakened roots restored with glass fiber posts, composite resin cores and complete metal crowns. Thirty maxillary canines were randomly divided into 3 groups of 10 teeth each: teeth without weakened roots (control); teeth with partially weakened roots (PWR) and teeth with and largely weakened roots (LWR). The control group was restored with glass fiber posts and a composite resin core. Teeth in the PWR and LWR groups were flared internally to standardized dimensions in order to simulate root weakness. Thereafter, the roots were partially filled with composite resin and restored in the same way as in the control group. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis of the tooth until failure. Data were analyzed by one-way ANOVA and Dunnett's test for multiple comparisons (p=0.05). There were statistically significant difference differences (p<0.01) among the groups (control group = 566.73 N; PWR = 409.64 N; and LWR = 410.91 N), with significantly higher fracture strength for the control group. There was no statistically significant difference (p>0.05) between the weakened groups. The results of this study showed that thicker root dentin walls significantly increase the fracture resistance of endodontically treated teeth.

2011 ◽  
Vol 22 (3) ◽  
pp. 230-237 ◽  
Author(s):  
Gisele Rodrigues da Silva ◽  
Paulo César de Freitas Santos-Filho ◽  
Paulo Cézar Simamoto-Júnior ◽  
Luis Roberto Marcondes Martins ◽  
Adérito Soares da Mota ◽  
...  

Restoring flared endodontically treated teeth continues to be a challenge for clinicians. This study evaluated the effect of post types and restorative techniques on the strain, fracture resistance, and fracture mode of incisors with weakened roots. One hundred five endodontically treated bovine incisors roots (15 mm) were divided into 7 groups (n=15). The two control groups were (C) intact roots restored with Cpc (cast posts and core) or Gfp (glass fiber posts). The five experimental groups were (F) flared roots restored with GfpAp (Gfp associated with accessory glass fiber posts), GfpRc (anatomic Gfp, relined with composite resin), and GfpRcAp (anatomized Gfp with resin and accessory glass fiber posts). All teeth were restored with metal crowns. Mechanical fatigue was performed with 3x10(5)/50 N. Specimens were loaded at 45º, and the strain values (μS) were obtained on root buccal and proximal surfaces. Following that, the fracture resistance (N) was measured. One-way ANOVA and Tukey's HSD tests (α=0.05) were applied, and failure mode was checked. No significant difference in strain values among the groups was found. Cpc presented lower fracture resistance and more catastrophic failures in flared roots. Gfp associated with composite resin or accessory glass fiber posts seems to be an effective method to improve the biomechanical behavior of flared roots.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Vineeta Nikhil ◽  
Padmanabh Jha ◽  
Akarshak Aggarwal

Aim. The aim of this study was to compare the fracture resistance of simulated immature teeth restored with gutta-percha, glass fiber posts (GFP), experimental dentine posts (DP) or Intracanal composite Resin (ICR).Materials and Methods. Fifty maxillary canines were decoronated, standardized and enlarged until, number 5 Peeso reamers were allowed to simulate immature teeth. After placement of 5 mm of MTA, the canals were divided into 5 groups and filled as follows: Group 1: AH Plus + gutta-percha, lateral compaction; Group 2: GFP luted with PARACORE dual cure resin; Group 3: DP luted with PARACORE dual cure resin; Group 4: PARACORE dual cure resin. A standardized core was built in all groups except in Group 5. Each of the specimens was tested for fracture resistance by universal testing machine.Results. The mean fracture resistance were 817 ± 27.753, 1164.6 ± 21.624, 994.4 ± 96.8747, 873.8 ± 105.446 and 493.7 ± 6.945 newtons for Groups 1, 2, 3, 4, and 5 respectively. Independent “t” test revealed statistically significant discrepancies, in the fracture resistance among the 4 groups except Group 1 and Group 4 (P<0.05).Conclusions. This study suggests that GFP and DP may be preferred for additional reinforcement of immature teeth.


2015 ◽  
Vol 03 (02) ◽  
pp. 080-084
Author(s):  
Vijay Singh ◽  
Poonam Bogra ◽  
Saurabh Gupta ◽  
Navneet Kukreja ◽  
Neha Gupta

AbstractFracture resistance of endodontically treated teeth restored with post. Aims: This study aims to compare the fracture resistance of endodontically treated teeth restored with resin fiber and stainless steel post. Commercially available prefabricated resin fiber post(Dentsply Maillefer Easy Post), prefabricated stainless steel post(Coltene/Whaledent Parapost) were used. Methods and Material: Forty five maxillary central incisors were obturated and divided into 3 groups: Control Group (Group I) without any post (n = 15), Resin Fiber Post Group (Group II) (n = 15) and Stainless Steel Post Group (Group III) (n = 15). In all Groups except control group, post space was prepared; a post was cemented, and a core build-up was provided. All the specimens were subjected to compressive force under a universal testing machine until fracture. Statistical analysis used: The results were analyzed using the variable analysis test (ANOVA). Results: One-way analysis of variance revealed significant difference among test groups. The control group demonstrated highest fracture resistance (925.2183 N), followed by the resin fiber post group (486.7265 N) and stainless steel post group (423.539N). Conclusions: Teeth restored with resin fiber post showed higher fracture resistance values than prefabricated stainless steel post.


2008 ◽  
Vol 9 (7) ◽  
pp. 33-40 ◽  
Author(s):  
Güliz Görgül ◽  
Bagdagül Helvacioglu Kivanç

Aim The aim of this study was to investigate the fracture strength of three post systems cemented with a dual cure composite resin luting cement by using different adhesive systems. Methods and Materials In this study 63 extracted anterior teeth with single roots were endodontically prepared and filled. Teeth were randomly assigned to one of three post systems placed into the prepared canals: Group I - titanium posts (n=21) (Filpost); Group II - glass fiber posts (n=21) (Mirafit White); and Group III zirconia posts (n=21) (CosmoPost). Each group was again randomly divided into three subgroups according to the bonding materials used [Single Bond (n=7), Clearfil SE Bond (n=7), and Prompt L Pop (n=7)]. A dual cured resin cement (Rely X ARC) was used for bonding the posts into the root canals. Standard cores were made by a composite resin (Clearfil Photocore) using core build-ups. The samples were tested in the compression test machine for 1 mm/min and fracture resistance of the teeth were recorded. The data was analyzed by using twoway analysis of variance (ANOVA) and Duncan's New Multiple Range Tests. A significance level of p<.05 was used for all comparisons. Results There was a significant difference in fracture resistance between the post systems (p<0.05) and the interaction of adhesive resins and post systems (p<0.05). Mirafit White was more resistant to fracture than other groups; Filpost showed the least resistance to fracture. CosmoPost post system bonded with Single Bond recorded the lowest fracture resistance (p<0.05). Conclusion Endodontically treated anterior teeth restored with glass fiber posts exhibited higher failure loads than teeth restored with zirconia and titanium posts. Self-etching adhesives are better alternatives to etch-andrinse adhesive systems for luting post systems. Clinical Significance Under the condition of this study, glass fiber posts are preferable to restore endodontically treated anterior teeth. Citation Kivanç BH, Görgül G. Fracture Resistance of Teeth Restored with Different Post Systems Using Newgeneration Adhesives. J Contemp Dent Pract 2008 November; (9)7:033-040.


2015 ◽  
Vol 26 (3) ◽  
pp. 211-215 ◽  
Author(s):  
Gustavo Sivieri-Araujo ◽  
Mario Tanomaru-Filho ◽  
Juliane Maria Guerreiro-Tanomaru ◽  
Eduardo Antunes Bortoluzzi ◽  
Érica Gouveia Jorge ◽  
...  

The aim of this study was to evaluate the fracture resistance of simulated immature teeth after different intra-radicular treatments. Crowns and roots of bovine incisors were cut transversally and removed to simulate immature teeth. Root canal preparation and flaring were performed using a bur in crown-apex and apex-crown direction. The samples were distributed into 5 groups (n=10): Positive control (PoC) - no root canal flaring or filling; Negative control (NeC) - teeth were sectioned and their root canals were flared; Direct anatomical glass fiber post (RaP) - #2 Reforpost main glass fiber post relined with composite resin; Double tapered conical glass fiber posts (ExP) - #3 Exacto glass fiber post; and #2 Reforpost main glass fiber + Reforpin accessory glass fiber posts (RrP). In RaP, ExP and RrP, 4.0-mm apical plugs were done with MTA Angelus. The specimens were embedded in polystyrene resin inside cylinders and the periodontal ligament was simulated with a polyether-based impression material. The specimens were submitted to compressive fracture strength test (0.5 mm/min at 135° relative to the long axis of the tooth) in a servo-hydraulic mechanical testing machine MTS 810. Data were subjected to one-way ANOVA and Dunnett's C or Tukey's tests (α=0.05). The control groups (PoC and NeC) showed lower fracture strength than the experimental groups. NeC presented the lowest resistance and ExP presented the highest resistance among the experimental groups. The flaring procedures produced a detrimental effect on the fracture resistance of the bovine teeth. Glass fiber intra-radicular posts increased significantly the fracture resistance of simulated immature teeth.


2014 ◽  
Vol 111 (1) ◽  
pp. 30-34 ◽  
Author(s):  
Érico Braga Franco ◽  
Accacio Lins do Valle ◽  
Ana Lúcia Pompéia Fraga de Almeida ◽  
José Henrique Rubo ◽  
Jefferson Ricardo Pereira

2013 ◽  
Vol 24 (6) ◽  
pp. 626-629 ◽  
Author(s):  
Maria Isabel A. Faria ◽  
Erica Alves Gomes ◽  
Danielle Cristine Messias ◽  
Joao Manoel Silva Filho ◽  
Celso Bernardo Souza Filho ◽  
...  

The aim of this in vitro study was to evaluate the tensile strength of glass fiber posts submitted to different surface treatments. Forty-eight maxillary canines had their crowns sectioned and root canals endodontically treated. The roots were embedded in acrylic resin and distributed into 3 groups according to the surface treatment: Group I: the posts were treated with silane agent for 30 s and adhesive; Group II: the posts were cleaned with alcohol before treatment with silane agent and adhesive; Group III: the posts were submitted to conditioning with 37% phosphoric acid for 30 s before treatment with silane agent and adhesive. Each group was divided into 2 subgroups for adhesive polymerization or not before insertion into the canal: A - adhesive was not light cured and B - adhesive was light cured. All posts were cemented with Panavia F and the samples were subjected to tensile strength test in a universal testing machine at crosshead speed of 1 mm/min. Data were submitted to one-way ANOVA and Tukey's test at 5% significance level. There was statistically significant difference (p<0.01) only between group GIII-B and groups GI-A and GI-B. No significant difference was found among the other groups (p>0.05). It was concluded that the products used for cleaning the posts influenced the retention regardless of adhesive light curing.


2019 ◽  
Vol 13 (1) ◽  
pp. 454-461
Author(s):  
Manjeev Guragain ◽  
Suraj Mathema ◽  
Dinesh Rokaya

Background: Dowel Cores are often required in endodontically treated tooth to aid retention and resistance for a final prosthetic crown. Studies concerning the role of post-core systems on the fracture resistance with different dowel material remain controversial. Aim: This experimental study aimed to investigate the fracture resistance strength and failure mode of 3 dowel systems (glass fiber, indirect resin, and prefabricated metal with resin core). Methods: Twenty-one extracted human maxillary central incisors were first endodontically treated and then separated into 3 equal groups randomly;1st group consisted of glass fiber dowel, 2nd group consisted of indirect resin dowel, and 3rd group consisted of the prefabricated metal dowel. All specimens were restored with resin core and indirect resin crown. A testing force was applied with a universal testing machine (at 135 o angle) at 3 mm from the incisal edge of crown and forces were measured. Statistical tests were done using One-way ANOVA and Chi-square Test. Results: There was no significant difference (P-value >0.05) of the fracture resistance among glass fiber dowel, indirect resin dowel and pre-fabricated dowel with indirect resin crown. The prefabricated metal dowel had maximum fracture resistance (566 ±157.771 N) followed by Glass fiber dowel (541.047 ±199.571 N) and indirect resin dowel and post (444.550 ±139.788 N). Conclusion: Glass fiber dowel, indirect resin dowel and prefabricated metal dowel with resin core and indirect resin crown systems showed statistically insignificant fracture strength values and mode of failure.


2015 ◽  
Vol 40 (6) ◽  
pp. 567-580 ◽  
Author(s):  
AP Moraes ◽  
R Sarkis-Onofre ◽  
RR Moraes ◽  
MS Cenci ◽  
CJ Soares ◽  
...  

SUMMARY The role of silanes in the bonding of resin luting agents to glass-fiber posts (GFPs) is a controversial topic, and the question still remains whether post silanization is able to improve the retention of GFPs luted into root canals. Thus, this study was designed to determine whether evidence exists to justify silanization of GFPs before cementation to increase their retention into root canals. In vitro studies that evaluated the retention of GFPs cemented into root canals or artificial substrates and that used silane coupling agents for pretreatment of the post were selected. Searches were carried out in PubMed and Scopus databases with no publication year or language limits. The last search was carried out in August 2014. Two distinct data analyses were carried out: 1) control group (no post pretreatment) vs silane only and 2) post pretreatment + silane vs silane only. Pooled-effect estimates were obtained by comparing the difference between each bond strength mean value and were expressed as the weighted mean difference between groups (p≤0.05). A total of 178 articles were found, and 23 were included in the review. The results were affected by the substrate into which the GFPs were luted (teeth or artificial devices). The analysis between control group and silane only for studies that used artificial devices favored the use of silane (p&lt;0.0001), but considering studies that used teeth as substrate, no significant difference was observed (p=0.35). The analysis between silane only and pretreatment + silane did not show a significant difference between groups when artificial devices were used (p=0.71), whereas the analysis favored the use of post pretreatment + silane over silane (p&lt;0.00001) only when the GFPs were luted into teeth. In conclusion, this review indicates that silanization improves the retention of GFPs luted into root canals provided that selective surface pretreatments are applied to the post before silanization.


2019 ◽  
Vol 2019 ◽  
pp. 1-5
Author(s):  
Raneem S. Alofi ◽  
Ibraheem F. Alshiddi ◽  
Yasser F. AlFawaz ◽  
Abdulaziz Alsahhaf ◽  
Khulud Abdulrahman Al-Aali ◽  
...  

Objective. This in vitro study was designed to evaluate the influence of an Er,Cr:YSGG laser on the bond strength of zirconia and glass fiber posts with root dentin. Materials and methods. Ninety extracted single-rooted human teeth were randomized into 6 groups (n = 15/group) on the basis of different posts (zirconia/glass fiber) and Er,Cr:YSGG laser tips (axial and radial). Specimens were prepared for push-out testing with the help of a cutting machine; six slices (2 on each cervical, middle, and apical) of approximately 1 mm thickness were sectioned for all roots on a plane perpendicular to the long axis of the post. All specimens were placed into a universal testing machine with a defined 0.5 mm/min crosshead speed until the maximum failure load was obtained. Results. The highest mean push-out bond strength of the glass fiber and zirconia groups was achieved with laser treatment. The highest push-out bond strength was achieved with the axial fiber tip (7.63 ± 1.22 MPa), and the lowest was achieved with a radial fiber tip of the glass fiber group (6.98 ± 0.96 MPa). ANOVA showed a statistically significant difference between the groups (p=0.041). The mean push-out bond strength was found to be higher with an axial fiber tip for both cervical and apical segments in the glass fiber and zirconia groups (p<0.05). The independent t-test resulted in the overall highest mean push-out bond strength in the apical segments (p=0.026). Conclusion. Within the limits of the present in vitro research study, an enhancement in the push-out bond strength of resin cement, mainly in the cervical region of the root canal, was achieved after irradiation with an Er,Cr:YSGG laser using an axial fiber tip.


Sign in / Sign up

Export Citation Format

Share Document