scholarly journals Comparative Analysis of Double and Trifocal IOL Implantation in Femtosecond Laser-Assisted Cataract Surgery

2019 ◽  
Vol 16 (1S) ◽  
pp. 68-73 ◽  
Author(s):  
O. I. Orenburkina

Purpose: to compare the clinical results of implantations of bi-and trifocal intraocular lenses (IOL) in femtosecond laser-assisted cataract surgery. Patients and methods. The article presents the results of the Acrysof IQ Panoptix trifocal lens implantations in 84 patients (112 eyes) — the main group and Acrysof IQ Restor bifocal IOL implantations in 52 patients (98 eyes) — the control group. All patients underwent femtosecond laser-assisted cataract surgery (FLACS). The following data were evaluated: uncorrected distance visual acuity (UCDVA) , uncorrected near visual acuity (30–45 cm) and at an average distance (50–70 cm) at discharge, after 14 days, 1 and 3 months after the surgery under photopic and mesopic lighting conditions. Postoperative refractometry data; the defocusing curve was performed in patients with a high UCDVA (0.9–1.0) monocularly under photopic conditions using standard optotypes 14 days after surgery; aberrometry indicators. Results. It was shown that both lenses provided high uncorrected distance and near visual acuity in photopic lighting conditions. At the same time, the Acrysof IQ Panoptix lens provided significantly better visual acuity at an intermediate distance and was more resistant to defocusing conditions. Refraction data: after 1 month, emmetropia was observed in 87 % of patients in the main group and in 85 % of control group, after 6 months — 92 and 89 % respectively. There were no significant differences in high order aberrations and total aberrations between patients of the compared groups. Conclusion. The use of the PanOptix trifocal lens made it possible to obtain maximum visual acuity at different distances, regardless of the level of illumination.

2019 ◽  
Author(s):  
Jing Liu ◽  
Yi Dong ◽  
Yan Wang

Abstract Background : This study aims to evaluate the efficacy and safety of extended depth of focus (EDOF) intraocular lenes (IOLs) in cataract surgery. Methods: All comparative clinical trials that involved bilaterally implanting EDOF IOLs in patients with cataract were retrieved from the literature database. We used random effects models to pool weighted mean differences (WMD) and risk ratio (RR) for continuous and dichotomous variables, respectively. Results: Nine studies with a total of 1336 eyes were identified. The subgroup analysis was conducted according to the type of IOLs used in the control group. Compared with monofocal IOLs, EDOF IOLs produced better uncorrected intermediate visual acuity (WMD: -0.17, 95% CI: -0.26 to -0.08, P = 0.0001) and uncorrected near visual acuity (WMD: -0.17, 95% CI: -0.21 to -0.12, P < 0.00001). EDOF IOLs resulted in reduced contrast sensitivity, more frequent halos, however, higher spectacle independence (RR: 2.81, 95% CI: 1.06 to 7.46, P = 0.04) than monofocal IOLs. Compared with trifocal IOLs, EDOF IOLs produced worse near visual acuity (MD: 0.10, 95% CI: 0.07 to 0.13, P<0.0001). EDOF IOLs performed better than trifocal IOls in contrast sensitivity, and there were no significant difference in halos and spectacle independence. Serious postoperative complications were rare, with no adverse events were reported in most studies. Conclusions: Increasing the risk of contrast reduction and more frequent halos, EDOF IOLs provided better intermediate and near VAs than monofocal IOLs. At the expense of near vision, patients receiving EDOF IOLs have better contrast sensitivity than those receiving trifocal IOLs. Halo incidence and spectacle independence of EDOF IOLs were similar to those of trifocal IOLs.


2019 ◽  
Author(s):  
Jing Liu ◽  
Yi Dong ◽  
Yan Wang

Abstract Background This study aims to evaluate the efficacy and safety of extended depth of focus (EDOF) intraocular lenes (IOLs) in cataract surgery. Methods All comparative clinical trials that involved bilaterally implanting EDOF IOLs in patients with cataract were retrieved from the literature database. We used random effects models to pool weighted mean differences (WMD) and risk ratio (RR) for continuous and dichotomous variables, respectively. Results Nine studies with a total of 1336 eyes were identified. The subgroup analysis was conducted according to the type of IOLs used in the control group. Compared with monofocal IOLs, EDOF IOLs produced better uncorrected intermediate visual acuity (WMD: -0.17, 95% CI: -0.26 to -0.08, P = 0.0001) and uncorrected near visual acuity (WMD: -0.17, 95% CI: -0.21 to -0.12, P < 0.00001). EDOF IOLs resulted in reduced contrast sensitivity, more frequent halos, however, higher spectacle independence (RR: 2.81, 95% CI: 1.06 to 7.46, P = 0.04) than monofocal IOLs. Compared with trifocal IOLs, EDOF IOLs produced worse near visual acuity (MD: 0.10, 95% CI: 0.07 to 0.13, P<0.0001). EDOF IOLs performed better than trifocal IOls in contrast sensitivity, and there were no significant difference in halos and spectacle independence. Conclusions Increasing the risk of contrast reduction and more frequent halos, EDOF IOLs provided better intermediate and near VAs than monofocal IOLs. At the expense of near vision, patients receiving EDOF IOLs have better contrast sensitivity than those receiving trifocal IOLs. Halo incidence and spectacle independence of EDOF IOLs were similar to those of trifocal IOLs.


2021 ◽  
pp. 25-29
Author(s):  
M.M. Bikbov ◽  
◽  
O.I. Orenburkina ◽  
A.E. Babushkin ◽  
◽  
...  

Purpose. To study the results of femtosecond laser-assisted cataract surgery (FLACS) using RayOne diffractive trifocal IOLs in comparison with bifocal lenses. Material and methods. The patients were divided into 2 groups: the first group included 32 patients (46 eyes) who were implanted with a bifocal refractive IOL M-flex 630 F with +3 dptr addidation during FPCS. The second group consisted of 34 people (49 eyes) with implanted RayOne trifocal IOL. The surgical treatment was evaluated by determining uncorrected visual acuity (UCVA) in the distance, at close (30-45 cm) and medium distance (50-70 cm) at discharge, 1 month and six months after the operation in photopic and mesopic lighting conditions, with the study of postoperative refractometry data, the construction of a defocusing curve, and subjective assessment of patient satisfaction. Results. A month after tthe operation the postoperative spheroequivalent in the range of ±0.5 D was achieved in group 1 in 82.6% of cases and in group 2-in 91.8. Six months after surgery near visual acuity without correction in photopic and mesopic light conditions was on average 0.61±0.08, while in patients of group 2, the average values were recorded at 0.64±0.09 and 0.62±0.07, respectively. By this time, the patients of group 1 had significantly lower rates of UCVA at long and medium distances: 0.81±0.08 in photopic lighting conditions and 0.79±0.08 in mesopic conditions, and group 2 0.41±0.08 and 0.40±0.10, respectively. Conclusion. Patients who underwent FLACS with an implanted RayOne trifocal IOL, compared with patients with bifocal IOLs, had higher rates of subjective satisfaction with the results of surgical treatment and UCVA at various distances (including greater comfort with actions performed at close and medium distances) at different light levels. Key words: multifocal IOLs, femtosecond laser-assisted cataract surgery, RayOne Trifocal.


2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Agnieszka Dyrda ◽  
Ana Martínez-Palmer ◽  
Daniel Martín-Moral ◽  
Amanda Rey ◽  
Antonio Morilla ◽  
...  

Purpose. To present the outcomes of hybrid multifocal and monofocal intraocular lenses (IOLs) and to compare with refractive and diffractive multifocal IOLs (MFIOLs).Methods. Three hundred twenty eyes (160 patients) underwent cataract surgery with randomized IOLs bilateral implantation. Changes in uncorrected and distance-corrected logMAR distance, intermediate and near (UNVA and DCNVA) visual acuity (VA), contrast sensitivity (CS), presence of dysphotopsia, spectacle independence, and patient satisfaction were analyzed.Results. Postoperative VA in the hybrid (OptiVis) group was improved in all distances (p<0.001). OptiVis acted superiorly to monofocal IOLs in UNVA and DCNVA (p<0.001for both) and to refractive ones in DCNVA (p<0.005). Distance, mesopic, without glare CS in OptiVis was lower than in the monofocal group and similar to other MFIOLs. No differences in dysphotopsia pre- and postoperatively and spectacle independence in near for OptiVis and refractive MFIOLs were detected. OptiVis patients were more satisfied than those with monofocal IOLs (p=0.015).Conclusions. After cataract surgery, patients with OptiVis improved VA in all distances. Near and intermediate VA was better than monofocal, and DCNVA was better than the refractive group. CS was lower in OptiVis than in the monofocal group, but there was no difference between MFIOLs. Patient satisfaction was higher in OptiVis than in the monofocal group. This trial is registered withNCT03512626.


2021 ◽  
Vol 14 (3) ◽  
pp. 371-377
Author(s):  
Hui Liu ◽  
◽  
Hai-Jun Xia ◽  
Jin Zhou ◽  
◽  
...  

AIM: To analyze postoperative clinical results after implantation of trifocal intraocular lenses (IOLs) in highly myopic eyes with different axial lengths (ALs). METHODS: This retrospective study describes 61 eyes of 44 patients that were implanted with trifocal diffractive IOLs (AT LISA tri 839MP). Twenty-one eyes (15 patients) were included in the AL<26 mm group, 19 eyes (13 patients) in the AL≥26 mm and <28 mm group, and 21 eyes (16 patients) in the AL≥28 mm group. Postoperative outcomes, including corrected and uncorrected distance visual acuity (UDVA), intermediate and near visual acuity at 167 cd/m2 luminance, depth of focus at 85 cd/m2 luminance, and objective optical quality parameters assessed using the Optical Quality Analysis System (OQAS), were compared among the groups at 3mo. RESULTS: There were no significant differences in the mean UDVA, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity (DCNVA) among the three groups (P>0.05). Better near and intermediate visual acuity (from -1.5 D to -3.0 D) were noted on the defocus curve of the AL<26 mm group (P<0.01 vs AL≥28 mm group). Significantly higher objective scatter index (OSI) values and lower modulation transfer function (MTF) cut-off values, Strehl ratio (SR), and OQAS values (OVs) were observed in the AL≥28 mm group (P<0.01 vs AL<26 mm group). All OQAS parameters had statistically significant correlations with DCNVA and visual acuity at the vergence of -2.5 D (P<0.05 to P<0.01). CONCLUSION: Implantation of trifocal IOLs provides good short-term visual and refractive outcomes in highly myopic eyes with different ALs. However, the near vision decreases in the extremely myopic eyes at lower luminance, which is associated with the lower objective optical quality in these eyes.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yueyang Zhong ◽  
Kai Wang ◽  
Xiaoning Yu ◽  
Xin Liu ◽  
Ke Yao

AbstractThis meta-analysis aimed to evaluate the clinical outcomes following implantation of trifocal intraocular lenses (IOLs) or a hybrid multifocal-extended depth of focus (EDOF) IOL in cataract or refractive lens exchange surgeries. We examined 13 comparative studies with bilateral implantation of trifocal (898 eyes) or hybrid multifocal-EDOF (624 eyes) IOLs published through 1 March 2020. Better uncorrected and corrected near visual acuity (VA) were observed in the trifocal group (MD: − 0.143, 95% CI: − 0.192 to − 0.010, P < 0.001 and MD: − 0.149, 95% CI: − 0.217 to − 0.082, P < 0.001, respectively), while the hybrid multifocal-EDOF group presented better uncorrected intermediate VA (MD: 0.055, 95% CI: 0.016 to 0.093, P = 0.005). Trifocal IOLs were more likely to achieve spectacle independence at near distance (RR: 1.103, 95% CI: 1.036 to 1.152, P = 0.002). The halo photic effect was generated more frequently by the trifocal IOLs (RR: 1.318, 95% CI: 1.025 to 1.696, P = 0.031). Contrast sensitivity and subjective visual quality yielded comparable results between groups. Trifocal IOLs demonstrated better performance at near distance but apparently led to more photic disturbances. Our findings provided the most up-to-date and comprehensive evidence by comparing the benefits of advanced IOLs in clinical practice.


2021 ◽  
Vol 13 (01) ◽  
pp. e26-e31
Author(s):  
Spencer C. Cleland ◽  
Daniel W. Knoch ◽  
Jennifer C. Larson

Abstract Objective The study aimed to evaluate the safety and efficacy of resident surgeons performing femtosecond laser assisted cataract surgery (FLACS). Methods A retrospective chart review was conducted at the University of Wisconsin-Madison from postgraduate year four residents performing FLACS between 2017 and 2019. Data were also collected from residents performing manual cataract surgery, and attending surgeons performing FLACS for comparison. Recorded data included patient demographics, pre- and postoperative visual acuity, pre- and postoperative spherical equivalent, nuclear sclerotic cataract grade, ocular and systemic comorbidities, intraocular lens, duration of surgery, cumulative dissipated energy (CDE), and intraoperative and postoperative complications. Results A total of 90 cases were reviewed with 30 resident manual cases, 30 resident FLACS cases, and 30 attending FLACS cases. Resident manual (25.5 ± 6.8 minutes) and resident FLACS (17.5 ± 7.1 minutes) cases took a significantly longer time to complete compared with attending FLACS cases (13.6 ± 4.4 minutes; p < 0.001). There was higher CDE in resident FLACS and resident manual cases compared with attending FLACS cases, but the difference was not statistically significant (p = 0.06). Postoperative visual acuity was not statistically different at 1-day and 1-month after surgery among the three groups. Resident FLACS complications, which included one case requiring an intraoperative suture to close the wound, two cases with intraoperative corneal abrasions, two cases with postoperative ocular hypertension, and one case with cystoid macular edema, were not significantly greater than attending FLACS complications (p = 0.30). Conclusion The FLACS performed by resident surgeons had comparable visual acuity outcomes to FLACS performed by attending surgeons, and to manual cataract surgery performed by resident surgeons. However, resident FLACS cases took significantly longer time to complete, and they were associated with a higher CDE and minor complication rate compared with attending FLACS cases. Introducing advanced technologies into surgical training curricula improves resident preparedness for independent practice, and this study suggests FLACS can be incorporated safely and effectively into resident education.


2021 ◽  
Author(s):  
asli cetinkaya yaprak ◽  
Mustafa Unal

Abstract Purpose To evaluate the clinical outcomes and visual quality of patients undergoing cataract surgery with the implantation of two different models of diffractive trifocal intraocular lenses (IOLs).MethodsThis randomized prospective comparative study included 60 eyes of 15 patients who scheduled to undergo bilateral cataract surgery with the implantation of two models of diffractive trifocal IOLs (RayOne Trifocal and AcrySof IQ PanOptix IOL). Monocular and binocular corrected and uncorrected distance visual acuity (CDVA, UDVA), intermediate visual acuity (DCIVA, UIVA) at 60 and 80 cm, near visual acuity (DCNVA, UNVA), and patient satisfaction were compared over a three-month follow-up.ResultsEach group comprised 30 eyes of 15 patients. No statistically significant differences were determined between the groups in terms of CDVA, UDVA, DCNVA and UNVA. The monocular and binocular UIVA values at 60 cm were better in the PanOptix IOL group (p=0.04 and p=0.01, respectively), and the DCIVA and UIVA values at 80 cm were better in the RayOne IOL group (p=0.01, p=0.047, p<0.001, and p=0.042, respectively). No statistically significant difference was found between the groups in relation to the frequency and severity of visual symptoms evaluated. Regarding discomfort, the RayOne IOL group had more bothersome halos and starbursts (p=0.026 and p=0.01, respectively).ConclusionBoth IOLs provided very good restoration of visual acuity. However, with the AcrySof IQ PanOptix IOL, the likelihood of patients experiencing bothersome halos and starbursts was less. The RayOne Trifocal IOL might be a better choice for patients who require further intermediate vision.The study was registered under the World Health Organization international clinical trials registry platform: NCT04655274, 30/11/2020, prospectively registered.


2017 ◽  
Vol 27 (4) ◽  
pp. 460-465 ◽  
Author(s):  
Ramón Ruiz-Mesa ◽  
Antonio Abengózar-Vela ◽  
Ana Aramburu ◽  
María Ruiz-Santos

Purpose To compare visual outcomes after cataract surgery with bilateral implantation of 2 intraocular lenses (IOLs): extended range of vision and trifocal. Methods Each group of this prospective study comprised 40 eyes (20 patients). Phacoemulsification followed by bilateral implantation of a FineVision IOL (group 1) or a Symfony IOL (group 2) was performed. The following outcomes were assessed up to 1 year postoperatively: binocular uncorrected distance visual acuity (UDVA), binocular uncorrected intermediate visual acuity (UIVA) at 60 cm, binocular uncorrected near visual acuity (UNVA) at 40 cm, spherical equivalent (SE) refraction, defocus curves, mesopic and photopic contrast sensitivity, halometry, posterior capsule opacification (PCO), and responses to a patient questionnaire. Results The mean binocular values in group 1 and group 2, respectively, were SE -0.15 ± 0.25 D and -0.19 ± 0.18 D; UDVA 0.01 ± 0.03 logMAR and 0.01 ± 0.02 logMAR; UIVA 0.11 ± 0.08 logMAR and 0.09 ± 0.08 logMAR; UNVA 0.06 ± 0.07 logMAR and 0.17 ± 0.06 logMAR. Difference in UNVA between IOLs (p<0.05) was statistically significant. There were no significant differences in contrast sensitivity, halometry, or PCO between groups. Defocus curves were similar between groups from 0 D to -2 D, but showed significant differences from -2.50 D to -4.00 D (p<0.05). Conclusions Both IOLs provided excellent distance and intermediate visual outcomes. The FineVision IOL showed better near visual acuity. Predictability of the refractive results and optical performance were excellent; all patients achieved spectacle independence. The 2 IOLs gave similar and good contrast sensitivity in photopic and mesopic conditions and low perception of halos by patients.


Sign in / Sign up

Export Citation Format

Share Document