scholarly journals Three different interlocking intramedullary nails for unstable reverse oblique inter-trochanteric fractures: a bio-mechanical comparative study

Author(s):  
Ujjwal K. Debnath ◽  
S. Naidu Maripuri ◽  
K. N. Subramanian ◽  
K. Mohanty

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Biomechanical testing, intramedullary devices have proven advantageous over the extramedullary devices in the management of unstable intertrochanteric fractures. Reverse oblique type of intertrochanteric fractures are highly unstable and intramedullary nails are currently the method of internal fixation. The currently available nails seems to provide rotational, axial and angular stability, but biomechanical analysis of the strain pattern in the bone and implant in this fractures are lacking. The aim of this experimental study was to analyse the strain in three different long femoral nail-bone units under physiological loading when implanted in Saw bone model after creating a reverse oblique intertrochanteric fracture.</span></p><p class="abstract"><strong>Methods:</strong> A total of 12 sawbones were divided in to 4 equal groups. Group 1 was intact saw bones and were used as controls. Group 2, Group 3 and Group 4 were implanted with Depuy, Stryker and Synthes nails respectively after creating a reverse oblique intertrochanteric fracture. All the four groups were axially loaded with 100 N increments until physiological loads. The strain patterns were measured at the posteromedial cortex and the peak strains were extracted at partial weight bearing i.e. 500 N and full weight bearing physiological loads i.e. 1000 N.<strong></strong></p><p class="abstract"><strong>Results:</strong> <span lang="EN-IN">There was no significant difference in peak strains among the groups at partial loads. However at 1000 N loads the peak strain in the DePuy nail-bone unit was significantly high compared to the other two nail-bone units and the controls. </span></p><p class="abstract"><strong>Conclusions:</strong> These results question the safety of immediate full weight bearing following surgery when treating the reverse oblique unstable fractures with DePuy intramedullary nails. A period of partial weight bearing following fixation of reverse oblique fractures would be wise when using DePuy nails<span lang="EN-IN">.</span></p>

2020 ◽  
Vol 140 (12) ◽  
pp. 1947-1954
Author(s):  
Johannes Becker ◽  
M. Winkler ◽  
C. von Rüden ◽  
E. Bliven ◽  
P. Augat ◽  
...  

Abstract Introduction Aim of this study was to biomechanically compare two different acetabular cup fixation constructs in terms of fracture fixation for displaced acetabular fractures involving the anterior column with hemitransverse fracture under partial and full weight-bearing conditions. Methods Two different reinforcement rings designed as cages for primary THA were biomechanically tested in terms of managing a complex acetabular fracture. Single-leg stance cyclic loading was performed to assess fracture gap movement and fragment rotation. Twelve hemi pelvis Sawbones were divided into two groups: primary THA with acetabulum roof reinforcement plate (ARRP) (n = 6) and primary THA with Burch–Schneider reinforcement cage (BSRC) (n = 6). Results During loading under partial weight-bearing (250 N) fracture gap movement tended to be larger in the BSRC group as compared to the ARRP group. Under full weight-bearing conditions, the ARRP showed 60% significantly less motion (p = 0.035) of the os ilium to os ischii gap compared to BSRC. Fracture gap movements between the os ilium and spina iliaca fragments were significantly reduced by 76% (p = 0.048) for ARRP in contrast to BSRC. The ARRP group also demonstrated significantly less movement in the fracture gaps os ischii to quadrilateral plate (62% reduction, p = 0.009) and quadrilateral plate to spina iliaca (87% reduction, p < 0.001). Significantly less rotational movement of the quadrilateral plate to the os ilium was exhibited by the ARRP group (p = 0.015). Conclusions The presented acetabulum roof-reinforcement plate (ARRP) provides stable conditions at the acetabular component with adequate stabilization of a displaced acetabular fracture.


Author(s):  
Franziska Leiss ◽  
Julia Sabrina Götz ◽  
Matthias Meyer ◽  
Günther Maderbacher ◽  
Jan Reinhard ◽  
...  

Abstract Background Femoral component subsidence is a known risk factor for early failure of total hip arthroplasty (THA) using cementless stems. The aim of the study was to compare an enhanced recovery concept with early full weight-bearing rehabilitation and partial weight-bearing on stem subsidence. In addition, the influence of patient-related and anatomical risk factors on subsidence shall be assessed. Methods One hundred and fourteen patients underwent primary cementless THA and were retrospectively analyzed. Sixty-three patients had an enhanced recovery rehabilitation with early full weight-bearing and 51 patients had rehabilitation with partial weight-bearing (20 kg) for 6 weeks. Postoperative subsidence was analyzed on standing pelvic anterior–posterior radiographs after 4 weeks and 1 year. Subsidence was measured in mm. Anatomical and prosthetic risk factors (stem size, canal flare index, canal fill ratio as well as BMI and demographic data) were correlated. Results Femoral stem subsidence rate was significantly higher for the group with an enhanced recovery concept compared to the group with partial weight-bearing at the first radiological follow up after 4 weeks [2.54 mm (SD ± 1.86) vs. 1.55 mm (SD ± 1.80)] and the second radiological follow up after 1 year [3.43 mm (SD ± 2.24) vs. 1.94 (SD ± 2.16)] (p < 0.001, respectively). Stem angulation > 3° had a significant influence on subsidence. Canal flare index and canal fill ratio showed no significant correlation with subsidence as well as BMI and age. Conclusion In the present study, cementless stem subsidence was significantly higher in the group with enhanced recovery rehabilitation compared to partial weight-bearing. Small absolute values and differences were demonstrated and therefore possibly below clinical relevance. Anatomical radiological parameters and anthropometric data did not appear to be risk factors for stem subsidence.


2018 ◽  
Vol 4 (1) ◽  
pp. e000326 ◽  
Author(s):  
Stephen G Thompson ◽  
Rhodri D Phillip ◽  
Andrew Roberts

AimTo compare the interpretation of toe touch weight bearing (TTWB) and partial weight bearing (PWB) among orthopaedic surgeons, rehabilitation professionals and patients.Methodology78 consultant and middle-grade orthopaedic surgeons in the UK completed a questionnaire. 64 rehabilitation professionals (including physiotherapists) at Defence Medical Rehabilitation Centre Headley Court were also recruited. Both groups provided their interpretation of TTWB and PWB as a percentage of total body weight (%TBW). Each rehabilitation professional, then applied what they interpreted to be TTWB and PWB using a Lasar Posture weighing device. The predicted values were compared with the actual values demonstrated.ResultsThere was no significant difference between orthopaedic surgeons and rehabilitation professionals in their interpretation of TTWB and PWB, however there was a wide range of responses. There was a significant difference between the predicted %TBW and the actual values demonstrated by the ‘educated patient’ (mean difference 4.8 (TTWB) and 22.9 (PWB)).ConclusionHealthcare professionals vary greatly in their interpretation of the terms TTWB and PWB. Therefore, for a consistency in rehabilitation delivery the terms should not be used in isolation without a further descriptor. Static measures of weight application are lower than people think they are applying. We encourage the use of loading practice with a scale to reassure and educate patients.


SICOT-J ◽  
2018 ◽  
Vol 4 ◽  
pp. 16 ◽  
Author(s):  
Hélder Fonte ◽  
Ricardo Rodrigues-Pinto

Introduction: Femoral neck stress fractures are uncommon and depending on their location, can be at high risk for non-union and significant morbidity.  Their prevalence is higher among runners and military recruits, and women seem to be at higher risk. Methods: A 27-year-old female, who was enrolled in military recruit, reported left side groin pain after a strenuous running exercise. Due to persistent pain an X-Ray was ordered, which revealed no signs of acute lesions. Further imaging studies with CT scan and MRI identified a compression-type femoral neck stress fracture. Results: The patient was submitted to conservative treatment consisting of restricting from full weight-bearing. Six weeks after she initiated partial weight-bearing, becoming asymptomatic at seven months. Follow-up imaging studies revealed union of the fracture. Discussion: This diagnosis should be considered when evaluating military and athlete populations. Early recognition of these injuries is crucial because complication and morbidity rates are high.


Materials ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 52
Author(s):  
Nicholas A. Beckmann ◽  
Rudi G. Bitsch ◽  
Theresa Bormann ◽  
Steffen Braun ◽  
Sebastian Jaeger

Acetabular cup deformation may affect liner/cup congruency, clearance and/or osseointegration. It is unclear, whether deformation of the acetabular components occurs during load and to what extent. To evaluate this, revision multi-hole cups were implanted into six cadaver hemipelvises in two scenarios: without acetabular defect (ND); with a large acetabular defect (LD) that was treated with an augment. In the LD scenario, the cup and augment were attached to the bone and each other with screws. Subsequently, the implanted hemipelvises were loaded under a physiologic partial-weight-bearing modality. The deformation of the acetabular components was determined using a best-fit algorithm. The statistical evaluation involved repeated-measures ANOVA. The mean elastic distension of the ND cup was 292.9 µm (SD 12.2 µm); in the LD scenario, 43.7 µm (SD 11.2 µm); the mean maximal augment distension was 79.6 µm (SD 21.6 µm). A significant difference between the maximal distension of the cups in both scenarios was noted (F(1, 10) = 11.404; p = 0.007). No significant difference was noted between the compression of the ND and LD cups, nor between LD cups and LD augments. The LD cup displayed significantly lower elastic distension than the ND cup, most likely due to increased stiffness from the affixed augment and screw fixation.


2020 ◽  
Vol 1 (1) ◽  
pp. 68-72
Author(s):  
Raymond Massaad ◽  
Said El Orra ◽  
Mohammed Dabbous ◽  
Ali Ibrahim ◽  
Antonella Massaad

Background: Stress fracture of the femoral neck is rare in children. Its differential diagnosis includes muscle strain, synovitis, infection, dysplasia, etc. Since physicians rarely see this type of fracture in children, they often overlook it or misdiagnose it.  Case Report: A seven-year-old girl presented to our service with right groin pain following a fall on her right hip 15 days ago. Pelvic and knee radiographs of her right limb showed a fracture line with sclerosis at the femoral neck. Magnetic-resonance imaging (MRI) confirmed the diagnosis of a stress fracture of the femoral neck. We opted for conservative management and gave the patient analgesics and limited weight-bearing with the help of crutches for eight weeks. Three weeks after her first visit, the patient presented with severe limping and inability to bear weight on her right leg. Right hip radiographic imaging showed a varus displaced fracture of the femoral neck, which we managed surgically with an open reduction and internal fixation using plate and screws, followed by immobilization of the right hip with a hip spica cast. Six weeks following the surgery, the patient had no complaints, and the radiographic images showed an appropriate reduction and signs of union. The patient was allowed to start partial weight-bearing for a further six weeks before proceeding to full weight-bearing. Conclusion: Our case emphasizes the importance of considering femoral neck stress fracture in children, through a thorough clinical evaluation and imaging analysis, especially for those carrying classical risk factors. Failure to do so can complicate the disease course and may lead to a displaced fracture requiring more invasive and timely management.


2021 ◽  
Vol 4 (6) ◽  
pp. 01-05
Author(s):  
Srivatsa M Shet ◽  
Subin Joseph ◽  
Kader Kalathinga ◽  
Hafiz Muhammed Koyappathody ◽  
Srikant Aruna Samantaray ◽  
...  

A Sixteen-year-old male had a road traffic accident resulting in crush and loss of lateral two metatarsals of the left foot. The Lateral plantar arch was reconstructed with a vascularized fibula osteocutaneous flap. Flap survived and partial weight-bearing was started by 3 months and full weight-bearing was started 6-months post-surgery. At a 16-month follow-up patient had a normal gait and integrity of the lateral plantar arch was maintained. Vascularized fibula osteocutaneous flap is an excellent option for one-stage reconstruction of the lateral arch of the foot and gives satisfactory results in terms of functions of foot and in avoiding long-term morbidity.


2021 ◽  
Vol 1 (6) ◽  
pp. 263502542110466
Author(s):  
Jörg Harrer ◽  
Max Schenke ◽  
Christoph Lutter ◽  
Jörg Dickschas ◽  
Matthias Feucht ◽  
...  

Background: Lower extremity alignment-correcting procedures for unicompartmental osteoarthritis are experiencing a rapid rise. Medial open-wedge high tibial osteotomy (MOW-HTO) thereby represents the most common technique among osteotomies but is limited in cases of severe malalignment. Some cases make a double-level osteotomy necessary. Indications: If planning of malalignment correction using a MOW-HTO results in a mechanical medial proximal tibial angle (mMPTA) of more than 93° (causing an oblique joint line), double-level osteotomy is indicated to avoid nonphysiological knee kinematics. Technique Description: After clinical examination and detailed analysis of malalignment (full-weight-bearing long-leg radiograph: hip-knee-angle [HKA], mMPTA, mechanical lateral distal femoral angle [mLDFA], joint line convergence angle [JLCA]), as well as individualized planning of the correction, the surgical procedure starts with an arthroscopy to evaluate the cartilage conditions and eventually treat intraarticular pathologies. Then, the femoral supracondylar correction is performed (closed wedge, biplanar osteotomy [ to increase bony healing]) according to the presurgical planning by resecting the osteotomy wedge with the measured length. K-wires are placed to check the correction. An angle-stable plate is used for osteosynthesis. The wedge taken out will be used as bone stock for the MOW-HTO afterward. The biplanar open-wedge tibial osteotomy is then performed subsequently using a medial tibial approach and an angle-stable plate. Opening of the osteotomy is then performed and double checked with intraoperative fluoroscopy using an alignment rod. Postoperative partial weight bearing for 6 weeks is recommended. Results: In recent literature, only few publications report on results of double-level osteotomies. Babis et al reports that it is a valuable procedure for patients with large varus deformity. Nakayama et al noted a significant improvement in patient-registered clinical outcomes in early postoperative evaluation of 20 patients. Schröter et al reports on 37 knees and findings include good clinical results, despite progressive osteoarthritis. Discussion/Conclusion: In cases of severe malalignment, adequate axis correction may require a double-level osteotomy. Exact preoperative planning is essential. Results reported in recent publications are promising. By splitting 1 large correction into 2 smaller ones, complications like hinge fracture and delayed bone healing are lowered.


2017 ◽  
Vol 2017 ◽  
pp. 1-6
Author(s):  
A-Bing Li ◽  
Wei-Jiang Zhang ◽  
Ji-Qi Wang ◽  
You-Ming Zhao ◽  
Wei-Jun Guo

Purpose. The purpose of this study is to evaluate the learning curve of performing surgery with the InterTan intramedullary nail in treating femoral intertrochanteric fractures, to provide valuable information and experience for surgeons who decide to learn a new procedure. Methods. We retrospectively analyzed data from 53 patients who underwent surgery using an InterTan intramedullary nail at our hospital between July 2012 and September 2015. The negative exponential curve-fit regression analysis was used to evaluate the learning curve. According to 90% learning milestone, patients were divided into two group, and the outcomes were compared. Results. The mean operative time was 69.28 (95% CI 64.57 to 74.00) minutes; with the accumulation of surgical experience, the operation time was gradually decreased. 90% of the potential improvement was expected after 18 cases. In terms of operative time, intraoperative blood loss, hospital stay, and Harris hip score significant differences were found between two groups (p=0.009, p=0.000, p=0.030, and p=0.002, resp.). Partial weight bearing time, fracture union time, tip apex distance, and the number of blood transfusions and complications were similar between two groups (p>0.5). Conclusion. This study demonstrated that the learning curve of performing surgery with the InterTan intramedullary nail is acceptable and 90% of the expert’s proficiency level is achieved at around 18 cases.


Sign in / Sign up

Export Citation Format

Share Document