Energy efficiency improvements in historic buildings: Analysis of a case study in central Italy

2018 ◽  
Vol 87 (3) ◽  
pp. 135-142 ◽  
Author(s):  
Paolo Zazzini ◽  
Marco Capone
2020 ◽  
Vol 12 (15) ◽  
pp. 6271
Author(s):  
Nenad Šekularac ◽  
Jelena Ivanović-Šekularac ◽  
Aleksandar Petrovski ◽  
Nikola Macut ◽  
Milan Radojević

A proper systematic approach to the restoration of historic buildings is crucial in the preservation of heritage buildings. This paper presents the unity between the restoration of a historic building and sustainability. The aim of the research is to establish an effective method for the restoration of historic buildings and their reuse and sustainable renovation in terms of energy efficiency, in accordance with modern needs and conservation requirements while maintaining the authentic appearance. The main method in the paper is the observation of a historic building during its restoration and exploitation, analysis and evaluation of the results achieved in improving energy efficiency and energy saving in the example of the building within the Žica Monastery in Serbia, a cultural monument of exceptional importance. The subject of the research is the Dining Room within the Žiča Monastery and the analysis of the restoration results in order to ensure energy refurbishment and cultural heritage enhancement. The research findings are recommendations for the restoration and adaptive re-use of historic buildings, in accordance with modern requirements for comfort and environmental protection. The greatest contribution of this paper is the practical verification of energy refurbishment of the restored historic building, the Dining Room, by applying the principles and measures of energy efficiency, maintaining the authentic appearance of the building, in accordance with the conservation requirements.


2016 ◽  
Vol 20 (4) ◽  
pp. 1363-1376 ◽  
Author(s):  
Jelena Ivanovic-Sekularac ◽  
Jasna Cikic-Tovarovic ◽  
Nenad Sekularac

A proper approach to restoration of historic buildings is crucial for monumental heritage protection. The objective of the paper is to define a methodology for historic buildings restoration in order to increase energy efficiency and re-usability in accordance with modern standards. The main method used in the paper is the observation of historic buildings during their restoration and exploitation, analysis and evaluation of achieved results regarding energy efficiency and energy saving, through the examples of the buildings belonging to Hilandar Monastery, Mount Athos, in Greece. Mount Athos was inscribed on the UNESCO World Heritage List for its cultural and natural values. This case study discusses the abandoned and dilapidated historic buildings of the Haybarn Complex (Stable, Mulekeepers? House and Haybarn), the achieved results regarding the restoration of these buildings, their energy efficiency and turning into the premises for occasional stays. The research results are recommendations for increasing energy efficiency while performing the restoration of historic buildings, so that these buildings could be re-used in a new way. The most significant contribution of the paper is the practical test of energy refurbishment of these historic buildings conducted using the principles and methods of energy efficiency, in compliance with conservation requirements and authenticity of historic buildings.


2020 ◽  
Vol 12 (21) ◽  
pp. 9223 ◽  
Author(s):  
Andrea Garzulino

The awareness that a historic building is a complex system made up of interdependent parts and endowed with a specific energetic behavior is now widespread. Therefore, the energy improvement of a historic building does not only consist of designing individual construction elements or high-performance materials. On the contrary, it is based on the ability to analyze the buildings and recognize and enhance the specific thermal characteristics of each individual situation. Over the past two decades, the publication of European directives aimed at improving the energy efficiency of existing buildings has led each country to promulgate national guidelines in order to help operators planning and implementing energy improvement actions for historic buildings. The guidelines of the Italian Ministry of Cultural Heritage prescribe a method to evaluate the effectiveness of different energy improvement interventions in historic buildings through a qualitative-quantitative analysis based on static energy simulation. However, the ministerial guidelines do not prescribe any method for the analytical evaluation of other key issues aimed at the success of any energy improvement action for the historic building. Based on the literary and standard review on EEHB 2000–2020, this paper presents a multi-criteria comparative analysis method of energy improvement techniques for historic buildings in order to support operators in choosing the most suitable action for each case study. The method analyses each energy improvement technique according to four parameters: energy efficiency (increase in expected efficiency), compatibility (ability to ensure the protection of the morphological, material, and architectural features of the historic building), durability, and cost effectiveness. The method is based on descriptive and analytic forms for the different parts of the historic building and for the different improvement actions. These have been experimentally verified on a masonry case study, representative of widespread built heritage. The result opens the possibility of implementing the national guidelines and increasing their effectiveness.


2021 ◽  
Vol 13 (19) ◽  
pp. 10531
Author(s):  
Yasmine Sabry Hegazi ◽  
Heidi Ahmed Shalaby ◽  
Mady A. A. Mohamed

Historic buildings still perform their role today by being utilized either for their original purpose or a new purpose for which they are adapted. These buildings have specific requirements that inhabitants must follow. These requirements and relating uses and maintenance procedures result from adaptive reuse decisions, which may not be the most optimal scenario. The imperative is that historic buildings are used in a manner that, on the one hand, does not endanger their value related to heritage and tradition, and on the other hand, guarantees a degree of utility for their inhabitants, such as acceptable performance with regards to either air cooling or heating. The challenge is how to optimize the use of energy for either air cooling or heating, provided that adaptive reuse decisions are grounded in certain very specific and very rigid principles. The latter render is extremely difficult to meet the twin challenges of ensuring energy efficiency and thermal comfort for inhabitants while at the same time complying with the adaptive reuse principles. To address this challenge and gain an insight into ways of navigating it, a Post Occupancy Evaluation (POE) is conducted in Former Soldier’s Residence in the Cairo Citadel, Cairo, Egypt, which is now used as the National Organization for Urban Harmony’s (NOUH) administrative head office, this research can be considered as a single domain from which many other possible multi-domains can be investigated while studying the case of adaptive reuse. Other aspects such as indoor environmental quality, air quality, acoustics and lighting might act as multiple approaches appear to be widely used according to this review study, and in the future, the authors intend to test this research with the current single approach used in this research, which is the thermal comfort. POE includes both objective and subjective assessment, the POE limitation at this research to those assessment while a multi-perceptional and behavioral factors might be used as physical, contextual, personal, and others. The simulation and the survey methods were employed consecutively to assess the case study. By considering the research results, it was determined that the building consumes unnecessary energy by its current use of air conditioning system.


2016 ◽  
Vol 10 (1) ◽  
pp. 99-117 ◽  
Author(s):  
Alberto De Marco ◽  
Giulio Mangano ◽  
Fania Valeria Michelucci ◽  
Giovanni Zenezini

Purpose – The purpose of this paper is to suggest the usage of the project finance (PF) scheme as a suitable mechanism to fund energy efficiency projects at the urban scale and present its advantages and adoption barriers. Design/methodology/approach – A case study is developed to renew the traffic lighting system of an Italian town via replacement of the old lamps with new light-emitting diode (LED) technology. Several partners are involved in the case project to construct a viable PF arrangement. Findings – The case study presents the viability of the proposed PF scheme that provides for acceptable financial returns and bankability. However, it also shows that the need for short concession periods may call for a public contribution to the initial funding to make the project more attractive to private investors. Practical implications – This case study is a useful guideline for governments and promoters to using the PF arrangement to fund energy efficiency investments in urban settings. It helps designing an appropriate PF scheme and understanding the advantages of PF to reduce risk and, consequently, increase the debt leverage and profitability of energy efficiency projects. Originality/value – This paper contributes to bridging the gap about the lack of works addressing the implementation of the PF mechanism in the energy efficiency sector in urban areas. The importance of this paper is also associated with the shortage of traditional public finance faced by many cities that forces to seek for alternate forms of financing.


Food Control ◽  
2021 ◽  
Vol 125 ◽  
pp. 107964
Author(s):  
Daniele Castiglione ◽  
Lisa Guardone ◽  
Francesca Susini ◽  
Federica Alimonti ◽  
Valeria Paternoster ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Muhammad Arif Budiyanto ◽  
Muhammad Hanzalah Huzaifi ◽  
Simon Juanda Sirait ◽  
Putu Hangga Nan Prayoga

AbstractSustainable development of container terminals is based on energy efficiency and reduction in CO2 emissions. This study estimated the energy consumption and CO2 emissions in container terminals according to their layouts. Energy consumption was calculated based on utility data as well as fuel and electricity consumptions for each container-handling equipment in the container terminal. CO2 emissions were estimated using movement modality based on the number of movements of and distance travelled by each container-handling equipment. A case study involving two types of container terminal layouts i.e. parallel and perpendicular layouts, was conducted. The contributions of each container-handling equipment to the energy consumption and CO2 emissions were estimated and evaluated using statistical analysis. The results of the case study indicated that on the CO2 emissions in parallel and perpendicular layouts were relatively similar (within the range of 16–19 kg/TEUs). These results indicate that both parallel and perpendicular layouts are suitable for future ports based on sustainable development. The results can also be used for future planning of operating patterns and layout selection in container terminals.


Sign in / Sign up

Export Citation Format

Share Document