scholarly journals Evaluation and Performance of Activated Sludge Hi-Kleen Treatment Plant (ASHTP): A Case Study

2021 ◽  
Vol 11 (2) ◽  
pp. 15-24
Author(s):  
Nur Diana Wakimin ◽  
Juferi Idris ◽  
Lydia Dundun Francis ◽  
Maureen Neging ◽  
Siti Rafiqah Muskil ◽  
...  

Pollutants from sewage wastewater are major concerns due to their environmental effects. Thus, an effective sewage wastewater treatment plant is important to ensure discharged effluent is well treated before it can be released to rivers or water streams. This study aims to evaluate the performance of the Activated Sludge Hi-Kleen Treatment Plant (ASHTP) located at H Block (ASHTP at H Block) and L Block (ASHTP at L Block) in UiTM Sarawak Branch, Samarahan Campus, Sarawak, Malaysia. The evaluation was based on physicochemical and removal efficiency namely pH, temperature, turbidity, chemical oxygen demand (COD), and total suspended solids (TSS) from raw influent and treated effluent. The findings indicated that the overall performance of both ASHTP at H Block and L Block were satisfactory where treated effluent meets the standard discharge limits of Environmental Quality (Sewage) Regulations 2009 (Standard B). For ASHTP at H Block, the removal efficiencies of turbidity, COD, and TSS were found to be 86.00, 13.76, and 88.02% respectively, in which the pH, temperature, turbidity, COD, and TSS of the treated effluent were 7.30, 28.10°C, 10.40 NTU, 14.10 mg/L and 8.90 mg/L respectively. Meanwhile, for ASHTP at L Block, the removal efficiencies of turbidity, COD, and TSS were found to be 43.20, 41.90, and 51.61% respectively, in which the pH, temperature, turbidity, COD, and TSS in the treated effluent were 7.30, 27.90°C, 21.10 NTU, 58.10 mg/L and 18.00 mg/L respectively. Proper maintenance of sewage treatment plant is important to ensure its effectiveness as well as to prolong its lifespan.

Author(s):  
Dhanraj M R ◽  
◽  
Ganesha A ◽  

The aim of this study is to evaluate the quality of sewage generated from 7000 KLD Sewage Treatment Plant (STP) located at Manipal Institute of Technology, Manipal Karnataka which is based on the Activated Sludge Technology. The study of sewage quality of this plant is essential as most of the treated effluent discharged into a stream during monsoon and remaining season used for a Gardening purpose. Water samples were collected from the outlet and analyzed for the major waste-water quality parameters, such as pH, Biochemical Oxygen Demand (BOD) and residual chlorine. The overall quality of sewage of 7000 KLD Sewage treatment plants will be evaluated by collecting samples. The results of these evaluations also determine whether the effluent discharged into the water body is under limits given by Karnataka state pollution control board (KSPCB) & BIS standards.


2017 ◽  
Vol 76 (8) ◽  
pp. 2003-2014 ◽  
Author(s):  
Pollyane Diniz Saliba ◽  
Marcos von Sperling

The objective of this study was to evaluate the behaviour of a system comprising an upflow anaerobic sludge blanket reactor followed by activated sludge to treat domestic sewage. The Betim Central sewage treatment plant, Brazil, was designed to treat a mean influent flow of 514 L/s. The study consisted of statistical treatment of monitoring data from the treatment plant covering a period of 4 years. This work presents the concentrations and removal efficiencies of the main constituents in each stage of the treatment process, and a mass balance of chemical oxygen demand (COD) and nitrogen. The results highlight the good overall performance of the system, with high mean removal efficiencies: BOD (biochemical oxygen demand) (94%), COD (91%), ammonia (72%) and total suspended solids (92%). As expected, this system was not effective for the removal of nutrients, since it was not designed for this purpose. The removal of Escherichia coli (99.83%) was higher than expected. There was no apparent influence of operational and design parameters on the effluent quality in terms of organic matter removal, with the exceptions of the BOD load upstream of the aeration tank and the sludge age in the unit. Results suggest that this system is well suited for the treatment of domestic sewage.


Irriga ◽  
2021 ◽  
Vol 1 (4) ◽  
pp. 671-677
Author(s):  
LIBIANE MARINHO BERNARDINO ◽  
PATRÍCIA DA SILVA COSTA ◽  
VERA LÚCIA ANTUNES DE LIMA ◽  
RENER LUCIANO DE SOUZA FERRAZ

POTENCIAL DE REÚSO DE EFLUENTES TRATADOS PARA IRRIGAÇÃO PERIURBANA NO MUNICÍPIO DE GUARABIRA/PB     LIBIANE MARINHO BERNARDINO1; PATRÍCIA DA SILVA COSTA2; VERA LÚCIA ANTUNES DE LIMA3 E RENER LUCIANO DE SOUZA FERRAZ4.   1 Mestranda em Gestão e Regulação em Recursos Hídricos, Unidade Acadêmica de Tecnologia do Desenvolvimento, UFCG, Rua Luiz Grande, s/n, Frei Damião, CEP 58540-000, Sumé, PB, Brasil, [email protected] 2 Doutoranda em Engenharia Agrícola, Unidade Acadêmica de Engenharia Agrícola, UFCG, Rua Aprigio Veloso, 882, Universitário, CEP 58429-900, Campina Grande, PB, Brasil, [email protected] 3 Profa. Doutora em Engenharia Agrícola, Unidade Acadêmica de Engenharia Agrícola, UFCG, Rua Aprigio Veloso, 882, Universitário, CEP 58429-900, Campina Grande, PB, Brasil, [email protected] 4 Prof. Doutor em Engenharia Agrícola, Unidade Acadêmica de Desenvolvimento Sustentável do Semiárido, UFCG, Rua Luiz Grande, s/n, Frei Damião, CEP 58540-000, Sumé, PB, Brasil, [email protected]     1 RESUMO   A água é um recurso finito que se encontra escasso, o que justifica a busca por gestão e inovação de práticas que a preserve. O objetivo da pesquisa é avaliar o potencial de reúso dos efluentes tratados para irrigação periurbana. Foram levantados dados de uma Estação de Tratamento de Esgotos (ETE), localizada no município de Guarabira, PB, e operada pela Companhia de Água e Esgotos do Estado da Paraíba (CAGEPA), durante o período de janeiro a dezembro de 2019. Analisou-se os seguintes parâmetros físico-químicos e bacteriológicos: Potencial Hidrogeniônico (pH), Condutividade Elétrica (CE), Demanda Bioquímica de Oxigênio (DBO), Demanda Química de Oxigênio (DQO), Sólidos Totais (ST), Oxigênio Dissolvido (OD), Fósforo Total, e Coliformes Termotolerantes. Os dados foram submetidos à análise descritiva e expresso em valores mínimos, máximos e médios. Os indicadores foram satisfatórios para irrigação restrita, porém com a necessidade de tratamento complementar para determinados cultivos. O potencial de reúso   dos efluentes tratados na ETE pode beneficiar uma área de 118,7 ha considerando uma demanda de irrigação de 18.000 m³ ha-1 ano-1, o que demonstra ser um recurso sustentável e que precisa ser regulamentado no Brasil.   Palavras-chave: recursos hídricos, resíduos líquidos, tratamento de água, fertirrigação.     BERNARDINO, L. M.; COSTA, P. S.; LIMA, V. L. A.; FERRAZ, L. R. S. REUSE POTENTIAL OF TREATED EFFLUENTS FOR PERIURBAN IRRIGATION IN THE MUNICIPALITY OF GUARABIRA/PB     2 ABSTRACT   Water is at the center of sustainable development and a finite resource that is in short supply, which justifies the search for management and innovation of practices that preserve it. This research aims to evaluate the potential for reuse of treated effluent for periurban irrigation. Data were collected from a Sewage Treatment Plant (STP), located in the municipality of Guarabira, PB, and operated by the Water and Sewage Company of the State of Paraíba (CAGEPA), during the period from January to December 2019, with the analysis of the following physicochemical and bacteriological parameters: Hipogenic Potential (pH), Electrical Conductivity (CE), Biochemical Oxygen Demand (DBO), Chemical Oxygen Demand (DQO), Total Solids (ST), Dissolved Oxygen (OD), Total Phosphorus, and Thermotolerant Coliforms. The data were submitted to the descriptive analysis and expressed as minimum, maximum and average values. The indicators were satisfactory for restricted irrigation, but with the need for complementary treatment for certain crops. The potential for reuse of the effluents treated in the ETE can benefit an area of 118.7 ha considering an irrigation demand of 18,000 m³ ha-1 year-1, which demonstrates to be a sustainable resource that needs to be regulated in Brazil.   Keywords: Water resources, liquid waste, water treatment, fertigation.


Author(s):  
Vinay Khewale

A sewage water treatment plant is necessary to receive and treat waste water (Domestic, Commercial, and Industrial). Its objective is to be convert harmful waste water to safe water environmentally and treated effluent and treated sludge suitable for reuse and disposal such as farm fertilizer. The characteristics of waste water have been performed followed by design of sewage treatment plant. The present study includes design of sewage treatment plant and analysis of waste water – PH value, Total Dissolved Solids (TDS), Total Suspended Solids (TSS), Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Solids (TS), Hardness, Chloride, Acidity, Oil, Fats and grease etc. The sample collection of waste water has been done in many times in a day to obtain an average value of major parameter. Followed by values of this parameter, calculations are done for designing the units of sewage treatment plant and layout is prepared for the same


2007 ◽  
Vol 56 (7) ◽  
pp. 33-40 ◽  
Author(s):  
Salmiati ◽  
M.R. Salim ◽  
R.Md. Hassan ◽  
K.Y. Tan

Biochemical products have been widely used for treatment of various types of wastewater. The treatment processes with the addition of biochemical products are quite attractive because of their simplicity, minimal use of equipment, they are environmentally friendly and are suitable for the removal of organic pollutants. The purpose of these products is to enhance the activities of beneficial microbes in order to improve treatment performance. This study was carried out to determine the potential of applying biochemical products in assisting and improving the performance of sewage treatment plants. In this study, four biochemical products, namely: Zeolite, Bio-C, Eco-B and Was-D, were applied to the sewage treatment plant. Analyses were carried out on several water quality parameters such as biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), oil & grease (O&G), phosphorus (P), ammoniacal nitrogen (AN) and sludge thickness (ST). From the results obtained, it can be seen that the overall performance of the treatment plant improved with most of the parameters studied were found to fulfill the DOE Standard B requirements. The performance of Bio-C was found to give better results than other products.


PLoS ONE ◽  
2015 ◽  
Vol 10 (6) ◽  
pp. e0131532 ◽  
Author(s):  
Magna C. Paiva ◽  
Marcelo P. Ávila ◽  
Mariana P. Reis ◽  
Patrícia S. Costa ◽  
Regina M. D. Nardi ◽  
...  

2017 ◽  
Vol 13 (2) ◽  
Author(s):  
B Vivekanandan ◽  
K Jeyannathann ◽  
A. Seshagiri Rao

Abstract The quality of a treated effluent changes when there is a sudden variation in the influent flow to the wastewater treatment plant during dry, rain, and storm weather conditions. In this study, various influent flow conditions in an activated sludge process are considered that affect the sensitivity of effluent variables such as chemical oxygen demand (COD), biological oxygen demand (BOD), nitrate nitrogen (SNO), ammonical nitrogen (SNH), and total nitrogen (TN) with respect to varying internal recycle flow rate (Qa), sludge recycle flow rate (Qr), sludge wastage flow rate (Qw) and oxygen transfer rate co-efficient of aerobic tanks (KLa(3,4,5)). The analysis has been carried out based on benchmark simulation model no.1 (BSM 1) plant layout which comprises of two models namely activated sludge model no.1 (ASM 1) and simple one dimensional (Simple 1-D) Takacs model. Based on the present analysis, it is observed that the changes in influent flow rate have larger impact on the effluent variables. This variation can be subdued by introducing additional tanks to smoothen the perturbations or using internal recycle rate from the fifth tank in order to maintain the flow around the optimal influent flow rate. The sludge wastage rate has a greater impact on all effluent variables except nitrogenous variables during maximum flow conditions.


Sign in / Sign up

Export Citation Format

Share Document