scholarly journals PIPE CONDITION ANALYSIS USING ULTRASONIC TESTING TO PREDICT THE REMAINING SERVICE LIVE (RSL) OF THE PETROLEUM DISTRIBUTION PIPELINE

Konversi ◽  
2019 ◽  
Vol 8 (2) ◽  
Author(s):  
Sarah Dampang ◽  
Nanang Burhan ◽  
Cindi Ramayanti

The pipeline network in the petroleum industry is very susceptible to corrosion.  Corrosion problems can cause losses that are not small financially.  Corrosion that occurs in underground pipes can be in the form of external corrosion on the outer surface of the pipe caused by acid content in the air or in the soil or internal corrosion inside the pipe caused by petroleum content in the form of water, carbon dioxide (CO2) and hydrogen sulfide (H2S).  Corrosion causes the useful or service life of these pipes to be shorter than expected.  This study aims to measure the Remaining Service Life (RSL) of the petroleum distribution pipeline as an initial step of preventive action to avoid fatal consequences of corrosion problems.  In this study, ultrasonic testing was used as one of the Non Destructive Testing (NDT) methods to check the condition of the petroleum distribution pipe's wall.  In this study, it is found that the Remaining Service Life (RSL) of the pipeline under investigation is 25 years.

2005 ◽  
Vol 127 (3) ◽  
pp. 244-254 ◽  
Author(s):  
M. G. Lozev ◽  
R. W. Smith ◽  
B. B. Grimmett

Offshore pipeline failure statistics have been collected for more than 30 years now and illustrate that the riser predominantly fails as a result of corrosion. The consistent wetting and drying in the splash zone combined with defects in the coatings are the usual contributors to the problem. Risers are inspected at some determined frequency and can be done by internal and external methods. Inspecting by either means brings into account caveats and limitations from the technology used as well as human factors. For example, external inspections can be inefficient and inaccurate with some tools missing defects in areas of coating disbondment. In addition, internal inspections sometimes create false positives and can miss defects. These inaccuracies in the technologies or the techniques used may miss defects that eventually lead to failure. On the other hand, using corrosion mapping and fitness-for-service (FFS) assessment from the data collected, along with the inherent conservatism of this data from limited measurement accuracy, may result in the premature replacement of risers. A literature search is being conducted to review existing riser inspection methods and identify candidate nondestructive methods for riser inspection. These methods should be capable of detecting and monitoring general corrosion, localized corrosion pitting, and stress-corrosion cracking (sulfide or hydrogen induced) as external or internal corrosion damage. Thus far, this search has found that assessing the remaining service life of aging risers is largely dependent on the accuracy of analyzing corrosion damage to the riser surface in the atmospheric, splash (tidal), submerged, and buried environmental zones. The accuracy of each technology was analyzed. The capabilities and limitations of each method/technique used for riser inspection are summarized. The investigation is focused on long- and short-range ultrasonic techniques used for initial screening and corrosion mapping. These techniques can be deployed to detect a significant reduction in wall thickness using guided and torsional waves or to map accurately a corrosion damage using single/multiple transducers and phased-array probes in manual or automated mode. A pulsed eddy-current technique that uses a stepped or pulsed input signal for the detection of corrosion areas under insulation (CUI) is also being evaluated. This allows the detection of wall-thinning areas in the riser without removing the outside coatings. In addition, it is found that filmless, real-time, and digital radiography can be used to find internal and external corrosion defects in an insulated splash zone while the riser remains in service. A survey of nondestructive evaluation (NDE) manufacturing companies, NDE inspection companies, and operating companies was completed to collect information about current instrumentation and inspection/operators’ experience for riser inspection. Examples of advanced riser inspection instrumentation and field results are included. The ability of the candidate technologies to be adapted to riser variations, the stage of standardization, and costs are also discussed.


2016 ◽  
Vol 6 (2) ◽  
pp. 19-22 ◽  
Author(s):  
Gennadiy I. TITOV ◽  
Nadezhda A. NOVOPASHINA ◽  
Vyacheslav G. TITOV

Factors reduced the reliability of the heat supply networks is proposed to generalize to more substantive reasons. These are: external corrosion, internal corrosion and other reasons. The change of amount of heat damage to the outside network and internal corrosion, depending on the pipe diameter is introduced. The curve characterizing changes in the amount of heat damage to the network from external corrosion reliably obeys a normal distribution law. Recommendations to increase the service life of the heat pipe network are given.


Author(s):  
M. G. Lozev ◽  
R. W. Smith ◽  
B. B. Grimmett

Offshore pipeline failure statistics have been collected for more than 30 years now and illustrate that the riser predominantly fails as a result of corrosion. The consistent wetting and drying in the splash zone combined with defects in the coatings are the usual contributors to the problem. Risers are inspected at some determined frequency and can be done by internal and external methods. Inspecting by either means brings into account caveats and limitations from the technology used as well as human factors. For example, external inspections can be inefficient and inaccurate with some tools missing defects in areas of coating disbondment. In addition, internal inspections sometimes create false positives and can miss defects. These inaccuracies in the technologies or the techniques used may miss defects that eventually lead to failure. On the other hand, using corrosion mapping and fitness-for-service (FFS) assessment from the data collected, along with the inherent conservatism of this data from limited measurement accuracy, may result in the premature replacement of risers. A literature search is being conducted to review existing riser inspection methods and identify candidate nondestructive methods for riser inspection. These methods should be capable of detecting and monitoring general corrosion, localized corrosion pitting, and stress-corrosion cracking (sulfide or hydrogen induced) as external or internal corrosion damage. Thus far, this search has found that assessing the remaining service life of aging risers is largely dependent on the accuracy of analyzing corrosion damage to the riser surface in the atmospheric, splash (tidal), submerged, and buried environmental zones. The accuracy of each technology was analyzed. The capabilities and limitations of each method/technique used for riser inspection are summarized. The investigation is focused on long- and short-range ultrasonic techniques used for initial screening and corrosion mapping. These techniques can be deployed to detect a significant reduction in wall thickness using guided and torsional waves or to map accurately a corrosion damage using single/multiple transducers and phased-array probes in manual or automated mode. A pulsed eddy-current technique that uses a stepped or pulsed input signal for the detection of corrosion areas under insulation (CUI) is also being evaluated. This allows the detection of wall-thinning areas in the riser without removing the outside coatings. In addition, it is found that filmless, real-time, and digital radiography can be used to find internal and external corrosion defects in an insulated splash zone while the riser remains in service. A survey of nondestructive evaluation (NDE) manufacturing companies, NDE inspection companies, and operating companies was completed to collect information about current instrumentation and inspection/operators’ experience for riser inspection. Examples of advanced riser inspection instrumentation and field results are included. The ability of the candidate technologies to be adapted to riser variations, the stage of standardization, and costs are also discussed.


1997 ◽  
Vol 503 ◽  
Author(s):  
H. Jiang ◽  
M. K. Davis ◽  
R. K. Eby ◽  
P. Arsenovic

ABSTRACTPhysical properties and structural parameters have been measured for ropes of nylon 6 as a function of the number of use operations. The fractional content of the α crystal form, sound velocity, birefringence, tensile strength and length all increase systematically and significantly with increasing the number of use operations. The fractional content of the γ crystal form and fiber diameter decrease with use. These trends indicate that the measurement of such properties and structural parameters, especially the length, provide a possible basis for establishing a reliable, rapid, and convenient nondestructive characterization method to predict the remaining service life of nylon 6 ropes.


Sign in / Sign up

Export Citation Format

Share Document