scholarly journals ANALISIS PERBANDINGAN DAYA DUKUNG PONDASI TIANG PANCANG BERDASAR HASIL UJI SPT DAN PENGUJIAN DINAMIS

2020 ◽  
Vol 4 (1) ◽  
pp. 30
Author(s):  
Hinawan Teguh Santoso ◽  
Juandra Hartono

<p><em>The foundation work is one of the main works in bridge construction. Failure of the foundation will be fatal for the entire bridge construction. Therefore, it is necessary to test the bearing capacity of the pile to determine the installed foundation capacity. The most accurate and most expensive method for determining the bearing capacity of a pile is a static load test, which is a full-scale trial method of giving a load 2 or 3 times greater than the designed load. Another method that is more economical and entirely accurate is using the High Strain Dynamics Pile Test (HSDPT) or often called the Pile Driving Analyzer (PDA) Test. This PDA test took a sample of 18 points of 600 mm diameter </em><em>pre-stressed concrete piles</em><em> on the Kaligawe Bridge located on Jalan Kaligawe KM 2+350, Semarang, Central Java. Based on the core drilling results, the soil layer was dominated by clay with an N-SPT value &lt; 30 to a depth of 45 meters. </em><em>The average bearing capacity of PDA test results is 432.4 tons or 0.4% greater when compared to the empirical approach based on N-SPT value (430.7 tons). The bearing capacity of the CAPWAP analysis is 401.0 tons or 7.3% less when compared to the PDA test, because the PDA test results are further processed using Signal Matching Analysis (SMA). CAPWAP analysis shows that the bearing capacity of piles is dominated by </em><em>friction resistance </em><em>by 71.7% and end resistance by 28.3% or by 4.4% difference when compared to the empirical approach, where the </em><em>friction resistance </em><em>value is 67.3% and end resistance is 32.7%. In general, it can be said that the PDA test is reliable enough to confirm the bearing capacity of the pile foundation that has been installed in the field.</em><em></em></p>

2013 ◽  
Vol 838-841 ◽  
pp. 854-857
Author(s):  
Rui Chao Cheng ◽  
Xin Yu

The bearing capacity characteristics and side friction characters of post-grouting pile were studied in the static load test which included two piles with post-grouting or not. When the pile head settlements were same, the loads applied on the pile top were used to analyze the bearing properties of post-grouting pile. We got the ultimate side friction of post-grouting pile after fitting test curves of relations between friction resistance and displacement. The tests indicate that both the bearing capacity characteristics and side friction of post-grouting pile are increased in various degrees.


2021 ◽  
Vol 337 ◽  
pp. 03006
Author(s):  
Verônica Ricken Marques ◽  
Antonio Belincanta ◽  
Mary-Antonette Beroya-Eitner ◽  
Jorge Luis Almada Augusto ◽  
Ewerton Guelssi ◽  
...  

In this study, the influence of soil moisture on the bearing capacity of piles founded in an unsaturated clay soil was investigated. The soil studied, composing the upper soil layer in Maringá, Brazil, is lateritic, has degree of saturation between 37% and 70% and has collapsible behaviour when wet. The bearing capacity was determined by full-scale load tests following the Brazilian Standard for Static Load Test. Two pile lengths, 4 m and 8 m, were considered. To analyse the influence of soil moisture, two tests were performed for each pile length: one in soil in its natural moisture content and another in pre-moistened soil. Results show that for both pile lengths, an increase in water content caused a significant reduction in bearing capacity, which is attributed to the decrease in the matric suction of the soil. This is confirmed by the results of the initial evaluation made on the variation of matric suction and its contribution to the bearing capacity with changes in water content. In summary, this study confirms that the pile bearing capacity in unsaturated soil is dependent on soil water content, highlighting the fact that the approach of assuming full saturation condition in the evaluation of the pile bearing capacity in such soil may give erroneous results. Moreover, this study demonstrate that the empirical methods most commonly used in Brazil for pile bearing capacity determination, the Décourt & Quaresma and Aoki & Velloso methods, are overly conservative when applied to the Maringá soil.


2014 ◽  
Vol 884-885 ◽  
pp. 698-701
Author(s):  
Yan Zheng Huang ◽  
Shao Bo Zhang ◽  
Wen Yang

Based on Winkler model and engineering example, the behavior of elastic long pile under horizontal load was analyzed in test status while pile top at free. The analysis results show that under same horizontal static load, the maximum of pile shaft bending moment in work status is higher than it in test status. Directly using the horizontal bearing capacity obtained by horizontal static load test in project design is unsafe and inapposite. The horizontal bearing capacity of pile in work status can be get based on the proportion coefficient of the horizontal resistance coefficient.


Different methods have been used to determine the pile bearing capacity such as static equations, dynamic equations, empirical methods (EMs), numerical methods, computer software programs, and the pile static load test, these methods were giving different values for pile bearing capacity. In this paper, three empirical methods (Ems) have been selected (Brinch-Hansen, Chin-Kondner, and Decourt) and (AllPile 6) software (AP) has been applied to determine the capacity load of piles for six cases study of drilled concrete piles with a diameter ranging from 800 mm to 1500mm and embedded length ranged 10.5m to 26m. Four of those six piles are located at Portsudan city near the red seacoast and two piles are located in Khartoum city. The results of the pile bearing capacity (PC) calculations obtained using the above-mentioned different methods were compared with results produced by the pile load test. In all six cases study, the settlement of piles was limited, settlement failure was not reached. The results show that the AllPile 6 (AP) and the three mentioned empirical methods (Ems) gave reasonable piles bearing capacity, the (AP) and (BHM) gave the better result than the CKM and DM. While (DM) gave results similar to results determined using the (CKM). However, it was not preferred to use the (CKM) and (DM), unless the failure settlement has occurred in the pile load test.


2000 ◽  
Vol 37 (6) ◽  
pp. 1283-1294 ◽  
Author(s):  
Caizhao Zhan ◽  
Jian-Hua Yin

The Mass Transit Railway Corporation proposes to construct the Tseung Kwan O Depot (TKD) within Area 86 reclamation at Tseung Kwan O as part of the Tseung Kwan O Extension. The proposed foundation for the TKD comprises about 1000 large-diameter, bored, cast in situ, drilled shafts founded on or socketed into rock. To confirm the design allowable end bearing capacity and rock socket side resistance for the drilled shaft foundations, two test piles were constructed and tested. Both test piles were instrumented with strain gauges and rod extensometers. This paper presents the static compressive load test results on both test piles. The test results indicate that an end bearing capacity of 20.8 MPa (design allowable 7.5 MPa) and rock socket side resistance 2.63 MPa (design allowable 0.75 MPa) are achieved during the pile load tests with no sign of failure.Key words: drilled shaft, static load test, end bearing capacity, rock socket, rock socket side resistance, load transfer.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
A. Hemalatha ◽  
N. Mahendran ◽  
G. Ganesh Prabhu

The experimental investigation on the effects of granular fill and geogrid reinforced granular fill on the behaviour of the static liquefaction potential of the subsoil is reported in this study. A series of plate load test were carried out with different thickness of the granular fill, number of geogrid layers, and size/dimension of the footing. The test results were presented in terms of bearing capacity and subgrade modulus for the settlement ofδ10,δ15, andδ20. The experimental results revealed that the introduction of granular fill significantly increases the bearing capacity and effectively control the settlement behaviour of the footing. The introduction of geogrid in granular fill enhanced the Percentage of Control in Settlement and Bearing Capacity Ratio by a maximum of 328.54% and 203.41%, respectively. The introduction of geogrid in granular fill interrupts the failure zone of the granular fill and enhances the subgrade modulus of the footing by a maximum of 255.55%; in addition subgrade modulus of the footing was increased with an increase in the number of geogrid layers. Based on the test results it is suggested that the footing with large size has beneficial improvement on the reinforced granular fill.


2011 ◽  
Vol 250-253 ◽  
pp. 2271-2275
Author(s):  
Cheng Wang ◽  
Qi Zhang

Vertical static load test is widely used in the determination of pile bearing capacity, the mathematical model used to fit test pile data in determining the bearing capacity is essential. From the perspective of analytic geometry, the paper analyzes the traditional method of hyperbola, of which the asymptotic line of equilateral hyperbola was used to determine the ultimate bearing capacity. By extending the equal-axed conditions, a more general form of hyperbolic equation is derived and feasibility of such method is also analyzed, which indicates that the maximum point of curvature in such hyperbolic curve can determine the ultimate bearing capacity and such method is proved to be reasonable in practical projects.


2013 ◽  
Vol 790 ◽  
pp. 227-230
Author(s):  
Jian Feng Su ◽  
Yu Feng Xu

Floor slab static load test is a important method to judge the performance and carrying capacity of the slab. This paper, with the background of a factory frame-structure slab, introduced the testing scheme, the details of the testing process as well as the test results. The testing cases provide a useful reference for the same type of project.


Sign in / Sign up

Export Citation Format

Share Document