scholarly journals Evaluation of supplementary diagnostic value of contrast-enhanced ultrasound for lymph node puncture biopsy

2017 ◽  
Vol 9 (11) ◽  
pp. 4791-4797
Author(s):  
Jie Zhang ◽  
Xin Hao ◽  
Yang Yang ◽  
Chang-Shuai Yan ◽  
Chao Ma ◽  
...  
Author(s):  
Pēteris Priedītis ◽  
Maija Radziņa ◽  
Ilze Štrumfa ◽  
Zenons Narbuts ◽  
Arturs Ozoliņs ◽  
...  

Abstract The aim of the study was to investigate the diagnostic value of contrast-enhanced ultrasound (CEUS) in differentiating benign and malignant thyroid nodules. Thirty-five patients with morphologically proved thyroid nodules (17 malignant; 18 benign), underwent CEUS examination. Five enhancement patterns were evaluated: vascularisation, homogeneity, presence of peripheral rim type enhancement, wash-out rate of the contrast medium, and enhancement using microvascular imaging application. Time-intensity curves (TIC) were analysed in post-processing and defined as three types: slow versus rapid and stable versus rapid biphasic wash-out. Diagnostic value of the listed CEUS parameters was calculated. The results showed medium strength correlation between morphology (benign versus malignant nodule) and type of TIC curve rs = 0.38 (p = 0.021), as well as between mode of contrast enhancement rs = 0.39 (p = 0.022) and wash-out pattern rs =0.39 (p = 0.024). The overall pooled sensitivity of selected diagnostic parameters was 82%, specificity 57%, and accuracy 70%. Malignant nodules were characterised by iso- or hypovascular contrast enhancement and slow wash-out, while benign nodules showed hypervascular enhancement with rapid wash-out TIC curve and rim-like pattern. The CEUS patterns significantly differed between malignant and benign thyroid nodules with high diagnostic accuracy. Thus, CEUS has important clinical value as an additional tool to ultrasound and fine needle biopsy.


Diagnostics ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 2104
Author(s):  
Yangyang Zhu ◽  
Xiao Fan ◽  
Dan Yang ◽  
Tiantian Dong ◽  
Yingying Jia ◽  
...  

Background: Sentinel lymph node biopsy (SLNB), as a common method for axillary staging of early breast cancer, has gradually attracted people’s attention to the false-negative rate and postoperative complications. The aim of the study is to investigate the clinical value of preoperative contrast-enhanced ultrasound (CEUS) for intraoperative SLNB in early breast cancer patients. Methods: A total of 201 patients scheduled for SLNB from September 2018 to April 2021 were collected consecutively. Preoperative CEUS was used to identify sentinel lymph nodes (SLN) and lymphatic drainage in breast cancer patients. Results: The SLN identification rate of CEUS was 93.0% (187/201) and four lymphatic drainage patterns were found: single LC to single SLN (70.0%), multiple LCs to single SLN (8.0%), single LC to multiple SLNs (10.2%), and multiple LCs to multiple SLNs (11.8%). The Sen, Spe, PPV, NPV, AUC of CEUS, US and CEUS + US in diagnosis of SLNs were 82.7%, 80.4%, 73.8%, 87.4%, 0.815; 70.7%, 77.7%, 68.0%, 79.8%, 0.742; and 86.7%, 77.7%, 72.2%, 89.7%, 0.822, respectively. There was no statistically significant difference between the diagnostic performance of CEUS and CEUS + US (p = 0.630). Conclusions: CEUS can be used to preoperatively assess the lymphatic drainage patterns and the status of the SLNs in early breast cancer to assist precision intraoperative SLNB.


2021 ◽  
Vol 94 (1120) ◽  
pp. 20200880
Author(s):  
Fan Zhang ◽  
Lifang Jin ◽  
Gang Li ◽  
Chao Jia ◽  
Qiusheng Shi ◽  
...  

Objectives: To assess the value of contrast-enhanced ultrasound (CEUS) for diagnosing malignant non-mass breast lesions (NMLs) and to explore the CEUS diagnostic criteria. Methods: A total of 116 patients with 119 NMLs detected by conventional US were enrolled. Histopathological results were used as the reference standard. The enhancement characteristics of NMLs in CEUS were compared between malignant and benign NMLs. The CEUS diagnostic criteria for malignant NMLs were established using independent diagnostic indicators identified by binary logistic regression analysis. The diagnostic performance of Breast Imaging Reporting and Data System-US (BI-RADS-US), CEUS, and BI-RADS-US combined with CEUS was evaluated and compared. Results: Histopathological results showed 63 and 56 benign and malignant NMLs. Enhancement degree (OR = 5.75, p = 0.003), enhancement area (OR = 4.25, p = 0.005), and radial or penetrating vessels (OR = 7.54, p = 0.003) were independent diagnostic indicators included to establish the CEUS diagnostic criteria. The sensitivity and specificity of BI-RADS-US, CEUS, and BI-RADS-US combined with CEUS were 100 and 30.2%, 80.4 and 74.6%, and 94.6 and 77.8%, respectively; the corresponding areas under the receiver operating characteristic curve (AUC) were 0.819, 0.775, and 0.885, respectively. Conclusions: CEUS has a high specificity in malignant NML diagnosis based on the diagnostic criteria including enhancement degree, enhancement area, and radial or penetrating vessels, but with lower sensitivity than BI-RADS-US. The combination of CEUS and BI-RADS-US is an effective diagnostic tool with both high sensitivity and specificity for the diagnosis of malignant NMLs. Advances in knowledge: In this study, we assessed the diagnostic value of CEUS for malignant NMLs and constructed a feasible diagnostic criterion. We further revealed that the combination of CEUS and BI-RADS-US has a high diagnostic value for malignant NMLs.


Sign in / Sign up

Export Citation Format

Share Document