Soft Sensing for Gas-Lift Wells

SPE Journal ◽  
2006 ◽  
Vol 11 (04) ◽  
pp. 454-463 ◽  
Author(s):  
Hayco Bloemen ◽  
Stefan Belfroid ◽  
Wilco Sturm ◽  
Frederic Verhelst

Summary This paper considers the use of extended Kalman filtering as a soft-sensing technique for gas lift wells. This technique is deployed for the estimation of dynamic variables that are not directly measured. Possible applications are the estimation of flow rates from surface and downhole pressure measurements or the estimation of parameters of a drift-flux model. By means of simulation examples, different configurations of sensor systems are analyzed. Finally, the estimation of drift-flux model parameters is demonstrated on real data from a laboratory setup. Introduction During the last 10 years, the industry has seen different downhole actuation technologies (commonly known as intelligent completions or under different trademarks) coming into existence. The goal of these technologies is ultimately to maximize the value of an asset by applying "right-time" optimization concepts borrowed from control engineering. Depending on the specific economics of the asset, this can be translated into more specific objectives such as speeding up of production, stabilization of unstable production, deferment of production of unwanted fluids, maximizing ultimate recovery, or a combination of some of the aforementioned short- and long-term objectives. Control theory concepts of optimization by means of a feedback loop require means for determining the deviation between the actual response and the desired response of the system. In wells, this often boils down to some sort of multiphase flow measurement. Different accurate multiphase-measurement technologies have been matured during the last decade, and the industry seems to be crossing the chasm between the early-adopter and the early-follower stages. Often for control purposes, direct measurements with high absolute accuracy are not required, as long as the measurements give a good indication of the relative change in the property that needs to be optimized. In different process industries, soft-sensing techniques were developed to determine variables where it is either impossible to directly measure the variables of interest or where it is economically not justifiable. In this paper, the concept of soft sensing is used; unmeasured dynamic variables (such as flow rates) are estimated from measured ones (i.e., pressures) by fitting a sufficiently accurate numerical model to the available measurements. We have looked at the gas lifted well application, where the lift gas rate may be controlled. Ideally this control would be based on directly measured multiphase flow rates, but in reality one often finds that this information is not available. Other measurements, such as surface and downhole pressure and temperature measurements, are more readily available and may be used for soft sensing. The paper is organized in the following manner: first, the model of the gas lifted well is described; then, the soft-sensing concepts are explained; and, finally, different examples and configurations are shown in which this technology is applied for estimating multiphase flows.

Energies ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3930 ◽  
Author(s):  
Fang ◽  
Meng ◽  
Wei ◽  
Xu ◽  
Li

Managed pressure drilling (MPD) is a drilling technique used to address the narrow density window under complex geological environments. It has widespread applications in the exploration and exploitation of oil and gas, both onshore and offshore. In this study, to achieve effective control of the downhole pressure to ensure safety, a gas–liquid two-phase flow model based on the drift flux model is developed to describe the characteristics of transient multiphase flow in the wellbore. The advection upwind splitting method (AUSM) numerical scheme is used to assist with calculation and analysis, and the monotonic upwind scheme for conservation laws (MUSCLs) technique with second-order precision is adopted in combination with the Van Leer slope limiter to improve precision. Relevant data sourced from prior literature are used to validate the suggested model, the results of which reveal an excellent statistical consistency. Further, the influences of various parameters in a field application, including backpressure, density, and mass flow, are analyzed. Over the course of later-stage drilling, a combination of wellhead backpressure and displacement is recommended to exercise control.


Volume 3 ◽  
2004 ◽  
Author(s):  
J. Howard Arthur ◽  
Charles D. Morgan ◽  
Cory D. Engelhard ◽  
Berton Austin

In some nuclear power plants, a passive siphon breaking system is used to prevent the spent fuel tank from draining in the event of a break in the vertical leg of the heat exchanger piping. A hole is drilled in the horizontal leg of the piping. When the water level in the tank drops below the pipe level air is sucked into the system. When sufficient air is entrained in the pipe the siphon will break. A model to predict the flow rate in a vertical siphon was developed in reference 1 using the homogeneous flow model. The predicted flow rates were greater than measured flow rates. In order to improve the predictive capability, pressure drop measurements were obtained from ten foot vertical test sections with nominal diameters of 0.5, 0.75, 1.0, 1.25, 1.5, and 2.0 inches. Values of the distribution parameter, Co, for the drift flux model were determined from the pressure drop data. When the model of reference 1 is changed from homogeneous flow to drift flux model with the distribution parameter determined from the pressure drop data, good agreement with measured liquid flow rates is obtained. The improved model, along with the correlation for the siphon break condition obtained provides a good method for determining the hole size required to break the siphon. There is a paucity of data for two-phase flow regime transition where the flow is in the downward direction that is typical in a siphon. Flow regime transition data were obtained using the test sections listed above. The flow map of Oshinowo2 et al. gave a reasonable prediction of the transition from bubbly to slug flow. None of the references investigated gave an adequate prediction of the point where the siphon would break. A correlation for the siphon break point was developed.


2018 ◽  
Vol 184 ◽  
pp. 251-258 ◽  
Author(s):  
Damon E. Turney ◽  
Dinesh V. Kalaga ◽  
Manizheh Ansari ◽  
Roman Yakobov ◽  
J.B. Joshi

2004 ◽  
Vol 126 (4) ◽  
pp. 539-545 ◽  
Author(s):  
Xiaodong Sun ◽  
Sidharth Paranjape ◽  
Seungjin Kim ◽  
Hiroshi Goda ◽  
Mamoru Ishii ◽  
...  

This paper presents an experimental study of local liquid velocity measurement in downward air-water bubbly and slug flows in a 50.8 mm inner-diameter round pipe. The axial liquid velocity and its fluctuations were measured by a laser Doppler anemometry (LDA) system. It was found that the maximum liquid velocity in a downward two-phase flow could occur off the pipe centerline at relatively low liquid flow rates and this observation is consistent with other researchers’ results. The comparisons between the liquid flow rates measured by a magnetic flow meter and those obtained from the local LDA and multi-sensor conductivity probe measurements showed good agreement. In addition, based on the local measurements the distribution parameter and the drift velocity in the drift-flux model were obtained for the current downward flow tests.


2004 ◽  
Vol 126 (4) ◽  
pp. 528-538 ◽  
Author(s):  
S. Kim ◽  
S. S. Paranjape ◽  
M. Ishii ◽  
J. Kelly

The vertical co-current downward air-water two-phase flow was studied under adiabatic condition in round tube test sections of 25.4-mm and 50.8-mm ID. In flow regime identification, a new approach was employed to minimize the subjective judgment. It was found that the flow regimes in the co-current downward flow strongly depend on the channel size. In addition, various local two-phase flow parameters were acquired by the multi-sensor miniaturized conductivity probe in bubbly flow. Furthermore, the area-averaged data acquired by the impedance void meter were analyzed using the drift flux model. Three different distributions parameters were developed for different ranges of non-dimensional superficial velocity, defined by the ration of total superficial velocity to the drift velocity.