scholarly journals Semi Field Evaluation of Freestanding Transfluthrin Passive Emanators and the BG Sentinel Trap as a “Push-Pull control Strategy” Against Aedes aegypti Mosquitoes

2020 ◽  
Author(s):  
Mgeni Mohamed Tambwe ◽  
Sarah Moore ◽  
Hassan Chilumba ◽  
Johnson Kyeba Swai ◽  
Jason Moore ◽  
...  

Abstract Background The use of volatile pyrethroids and odor-baited traps in a push-pull system has been shown to reduce house entry and outdoor bites for malaria vectors. This technology has the potential to control other outdoor biting mosquitoes such as Aedes aegypti that transmit arboviral diseases. In this study, semi-field experiments were conducted to evaluate whether a push-pull system could be used to reduce bites from Aedes.Methods The push and pull under investigation consisted of two freestanding transfluthrin passive emanators (FTPE), and a BG sentinel trap (BGS) respectively. The FTPE contained hessian strips treated with 5.25 g of transfluthrin active ingredient. The efficacies of FTPE and BGS alone and in combination were evaluated by human landing catch in a large semi-field system in Tanzania. We also investigated the protection of FTPE over six months. The data was analyzed using generalized linear mixed models with binomial distribution.Results Two FTPE have a protective efficacy (PE) of 61% (95% Confidence interval (CI): 52.18–69.91) against human landing rate of Aedes aegypti. The BGS did not significantly reduce mosquito landings; the PE was 2.14% (95% CI: -2.87-7.16). The combination of FTPE and BGS (push-pull) provided the PE of 64.46% (95% CI: 59.06–69.85). However, there was no significant difference in the protective efficacy between the push-pull and the two FTPE against Ae. aegypti (p = 0.286). The FTPE offered significant protection against Ae. aegypti at month three, with a PE of 46.44% (95% CI: 41.12–51.76), but not at six months with a PE of 2.20% (95% CI: -9.00-14.02).Conclusions The protective efficacy of the FTPE and the full push-pull system are similar, indicative that bite prevention is primarily due to the activity of the FTPE. While these results are encouraging for the FTPE, further work is needed for a push-pull system to be recommended for Ae. aegypti control. The three-month protection provided by the FTPE against Ae. aegypti bites suggests it would be a useful additional personal protection tool during dengue outbreaks, that does not require regular user compliance.

2020 ◽  
Author(s):  
Mgeni Mohamed Tambwe ◽  
Sarah Moore ◽  
Hassan Chilumba ◽  
Johnson Kyeba Swai ◽  
Jason Moore ◽  
...  

Abstract Background: Spatial repellents that drive mosquitoes away from treated area, and odour-baited traps, that attract and kill mosquitoes, can be combined and work synergistically in a push-pull system. Push-pull systems have shown to reduce house entry and outdoor biting rates of malaria vectors and so have the potential to control other outdoor biting mosquitoes such as Aedes aegypti that transmit arboviral diseases. In this study, semi-field experiments were conducted to evaluate whether a push-pull system could be used to reduce bites from Aedes . Methods: The push and pull under investigation consisted of two freestanding transfluthrin passive emanators (FTPE), and a BG sentinel trap (BGS) respectively. The FTPE contained hessian strips treated with 5.25g of transfluthrin active ingredient. The efficacies of FTPE and BGS alone and in combination were evaluated by human landing catch in a large semi-field system in Tanzania. We also investigated the protection of FTPE over six months. The data was analyzed using generalized linear mixed models with binomial distribution. Results: Two FTPE have a protective efficacy (PE) of 61. 2% (95% Confidence interval (CI): 52.2-69.9) against human landing rate of Aedes aegypti . The BGS did not significantly reduce mosquito landings; the PE was 2.1% (95% CI: -2.9-7.2). The combination of FTPE and BGS (push-pull) provided the PE of 64.5% (95% CI: 59.1-69.9). However, there was no significant difference in the protective efficacy between the push-pull and the two FTPE against Ae. aegypti (p=0.30). The FTPE offered significant protection against Ae. aegypti at month three, with a PE of 46.4% (95% CI: 41.1-51.8), but not at six months with a PE of 2.2 % (95% CI: -9.0-14.0). Conclusions: The protective efficacy of the FTPE and the full push-pull system are similar, indicative that bite prevention is primarily due to the activity of the FTPE. While these results are encouraging for the FTPE, further work is needed for a push-pull system to be recommended for Ae. aegypti control. The three-month protection provided by the FTPE against Ae. aegypti bites suggests it would be a useful additional personal protection tool during dengue outbreaks, that does not require regular user compliance.


2020 ◽  
Author(s):  
Mgeni Mohamed Tambwe ◽  
Sarah Moore ◽  
Hassan Chilumba ◽  
Johnson Kyeba Swai ◽  
Jason Moore ◽  
...  

Abstract Background: Spatial repellents that drive mosquitoes away from treated areas, and odour-baited traps, that attract and kill mosquitoes, can be combined and work synergistically in apush-pull system. Push-pull systems have been shown to reduce house entry and outdoor biting rates of malaria vectors and so have the potential to control other outdoor biting mosquitoes such as Aedes aegypti that transmit arboviral diseases. In this study, semi-field experiments were conducted to evaluate whether a push-pull system could be used to reduce bites from Aedes mosquitoes. Methods: The push and pull under investigation consisted of two freestanding transfluthrin passive emanators (FTPE), and a BG sentinel trap (BGS) respectively. The FTPE contained hessian strips treated with 5.25g of transfluthrin active ingredient. The efficacies of FTPE and BGS alone and in combination were evaluated by human landing catch in a large semi-field system in Tanzania. We also investigated the protection of FTPE over six months. The data was analyzed using generalized linear mixed models with binomial distribution.Results: Two FTPE had a protective efficacy (PE) of 61. 2% (95% Confidence interval (CI): 52.2-69.9) against human landing rate of Aedes aegypti. The BGS did not significantly reduce mosquito landings; the PE was 2.1% (95% CI: -2.9-7.2). The combination of FTPE and BGS (push-pull) provided the PE of 64.5% (95% CI: 59.1-69.9). However, there was no significant difference in the protective efficacy between the push-pull and the two FTPE against Ae. aegypti (p=0.30). The FTPE offered significant protection against Ae. aegypti at month three, with a PE of 46.4% (95% CI: 41.1-51.8), but not at six months with a PE of 2.2 % (95% CI: -9.0-14.0). Conclusions: The PE of the FTPE and the full push-pull system are similar, indicative that bite prevention is primarily due to the activity of the FTPE. While these results are encouraging for the FTPE, further work is needed for a push-pull system to be recommended for Ae. aegypti control. The three-month protection provided by the FTPE against Ae. aegypti bites suggests it would be a useful additional personal protection tool during dengue outbreaks, that does not require regular user compliance.


2021 ◽  
Author(s):  
Mgeni Mohamed Tambwe ◽  
Adam Saddler ◽  
Ummi Abdul Kibondo ◽  
Rajabu Mashauri ◽  
Katharina S. Kreppel ◽  
...  

Abstract Background The human landing catch (HLC) measures human exposure to mosquito bites and evaluates the efficacy of vector control tools. However, it may expose volunteers to potentially infected mosquitoes. The mosquito electrocuting trap (MET) and BG-Sentinel traps (BGS) represent alternative, exposure-free methods for sampling host-seeking mosquitoes. This study investigates whether these methods can be effectively used as alternatives to HLC for measuring the efficacy transfluthrin against Aedes aegypti. Methods The protective efficacy (PE) of freestanding passive transfluthrin emanators (FTPEs), measured by HLC, MET and BGS were compared in no-choice and choice tests. The methods were located 2 m from an experimental hut with FTPEs positioned 3 m on either side of them. For the choice experiment, a competitor HLC was included 10 m from the first collection point. One hundred laboratory-reared Ae. aegypti mosquitoes were released and collected for three consecutive hours. Results In the no-choice test, each method measured similar PE; HLC: 66% (95% confidence interval [CI]: 50–82), MET: 55% (95% CI: 48–63) and BGS: 64% (95% CI: 54–73). The proportion of mosquitoes recaptured was consistent between methods (20–24%) in treatment and varied (47–71%) in the control. However, in choice tests, the PE measured by each method varied; HLC: 37% (95% CI: 25–50%), MET: 76% (95% CI: 61–92) and BGS trap: 0% (95% CI: 0–100). Recaptured mosquitoes were no longer consistent between methods in treatment (2–26%) and remained variable in the control (7–42%). FTPE provided 50% PE to the second HLC 10 m away. In the control, the MET and the BGS were less efficacious in collecting mosquitoes in the presence of a second HLC. Conclusions Measurement of the PE in isolation was fairly consistent for HLC, MET and BGS. Because HLC is not advisable, it is reasonable to use MET / BGS as a proxy for HLC for testing VP in areas of active arboviruses endemic areas. The presence of a human host in close proximity invalidated the PE estimates from BGS and METs. Findings also indicated that transfluthrin can protect multiple people in the peridomestic area and that at short-range mosquitoes select humans over the BGS.


2021 ◽  
Vol 20 (1) ◽  
Author(s):  
Emmanuel Mbuba ◽  
Olukayode G. Odufuwa ◽  
Frank C. Tenywa ◽  
Rose Philipo ◽  
Mgeni M. Tambwe ◽  
...  

Abstract Background N,N-Diethyl-3-methylbenzamide (DEET) topical mosquito repellents are effective personal protection tools. However, DEET-based repellents tend to have low consumer acceptability because they are cosmetically unappealing. More attractive formulations are needed to encourage regular user compliance. This study evaluated the protective efficacy and protection duration of a new topical repellent ointment containing 15% DEET, MAÏA® compared to 20% DEET in ethanol using malaria and dengue mosquito vectors in Bagamoyo Tanzania. Methods Fully balanced 3 × 3 Latin square design studies were conducted in large semi-field chambers using laboratory strains of Anopheles gambiae sensu stricto, Anopheles arabiensis and Aedes aegypti. Human volunteers applied either MAÏA® ointment, 20% DEET or ethanol to their lower limbs 6 h before the start of tests. Approximately 100 mosquitoes per strain per replicate were released inside each chamber, with 25 mosquitoes released at regular intervals during the collection period to maintain adequate biting pressure throughout the test. Volunteers recaptured mosquitoes landing on their lower limbs for 6 h over a period of 6 to 12-h post-application of repellents. Data analysis was conducted using mixed-effects logistic regression. Results The protective efficacy of MAÏA® and 20% DEET was not statistically different for each of the mosquito strains: 95.9% vs. 97.4% against An. gambiae (OR = 1.53 [95% CI 0.93–2.51] p = 0.091); 96.8% vs 97.2% against An. arabiensis (OR = 1.08 [95% CI 0.66–1.77] p = 0.757); 93.1% vs 94.6% against Ae. aegypti (OR = 0.76 [95% CI 0.20–2.80] p = 0.675). Average complete protection time (CPT) in minutes of MAÏA® and that of DEET was similar for each of the mosquito strains: 571.6 min (95% CI 558.3–584.8) vs 575.0 min (95% CI 562.1–587.9) against An. gambiae; 585.6 min (95% CI 571.4–599.8) vs 580.9 min (95% CI 571.1–590.7) against An. arabiensis; 444.1 min (95% CI 401.8–486.5) vs 436.9 min (95% CI 405.2–468.5) against Ae. aegypti. Conclusions MAÏA® repellent ointment provides complete protection for 9 h against both An. gambiae and An. arabiensis, and 7 h against Ae. aegypti similar to 20% DEET (in ethanol). MAÏA® repellent ointment can be recommended as a tool for prevention against outdoor biting mosquitoes in tropical locations where the majority of the people spend an ample time outdoor before going to bed.


2019 ◽  
Vol 18 (1) ◽  
Author(s):  
Antoine Sanou ◽  
W. Moussa Guelbéogo ◽  
Luca Nelli ◽  
K. Hyacinth Toé ◽  
Soumanaba Zongo ◽  
...  

Abstract Background Measuring human exposure to mosquito bites is a crucial component of vector-borne disease surveillance. For malaria vectors, the human landing catch (HLC) remains the gold standard for direct estimation of exposure. This method, however, is controversial since participants risk exposure to potentially infected mosquito bites. Recently an exposure-free mosquito electrocuting trap (MET) was developed to provide a safer alternative to the HLC. Early prototypes of the MET performed well in Tanzania but have yet to be tested in West Africa, where malaria vector species composition, ecology and behaviour are different. The performance of the MET relative to HLC for characterizing mosquito vector population dynamics and biting behaviour in Burkina Faso was evaluated. Methods A longitudinal study was initiated within 12 villages in Burkina Faso in October 2016. Host-seeking mosquitoes were sampled monthly using HLC and MET collections over 14 months. Collections were made at 4 households on each night, with METs deployed inside and outside at 2 houses, and HLC inside and outside at another two. Malaria vector abundance, species composition, sporozoite rate and location of biting (indoor versus outdoor) were recorded. Results In total, 41,800 mosquitoes were collected over 324 sampling nights, with the major malaria vector being Anopheles gambiae sensu lato (s.l.) complex. Overall the MET caught fewer An. gambiae s.l. than the HLC (mean predicted number of 0.78 versus 1.82 indoors, and 1.05 versus 2.04 outdoors). However, MET collections gave a consistent representation of seasonal dynamics in vector populations, species composition, biting behaviour (location and time) and malaria infection rates relative to HLC. As the relative performance of the MET was somewhat higher in outdoor versus indoor settings, this trapping method slightly underestimated the proportion of bites preventable by LLINs compared to the HLC (MET = 82.08%; HLC = 87.19%). Conclusions The MET collected proportionately fewer mosquitoes than the HLC. However, estimates of An. gambiae s.l. density in METs were highly correlated with HLC. Thus, although less sensitive, the MET is a safer alternative than the HLC. Its use is recommended particularly for sampling vectors in outdoor environments where it is most sensitive.


2020 ◽  
Author(s):  
Emmanuel Mbuba ◽  
Olukayode Odufuwa ◽  
Frank Tenywa ◽  
Rose Philipo ◽  
Mgeni Tambwe ◽  
...  

Abstract Background: N,N-Diethyl-3-methylbenzamide (DEET) topical mosquito repellents are effective personal protection tools. However, DEET-based repellents tend to have low consumer acceptability because they are cosmetically unappealing. More attractive formulations are needed to encourage regular user compliance. This study evaluated the protective efficacy and protection duration of a new topical repellent ointment containing 15% DEET, MAÏA® compared to 20% DEET in ethanol using malaria and dengue mosquito vectors in Bagamoyo Tanzania.Methods: Fully balanced 3x3 Latin square design studies were conducted in large semi-field chambers using laboratory strains of Anopheles gambiae s.s, An. arabiensis and Aedes aegypti. Human volunteers applied either MAÏA® ointment, 20% DEET or ethanol to their lower limbs six hours before the start of tests. Approximately 100 mosquitoes per strain per replicate were released inside each chamber, with 25 mosquitoes released at regular intervals during the collection period to maintain adequate biting pressure throughout the test. Volunteers recaptured mosquitoes landing on their lower limbs for six hours over a period of six to 12-hours post-application of repellents. Data analysis was conducted using mixed-effects logistic regression.Results: The protective efficacy of MAÏA® and 20% DEET was not different for each of the mosquito strains: 95.9% vs 97.4% against An. gambiae (OR=1.53 [95% CI: 0.93–2.51] p=0.091); 96.8% vs 97.2% against An. arabiensis (OR =1.08 [95% CI: 0.66 –1.77] P=0.757); 93.1% vs 94.6% against Ae. aegypti (OR=0.76 [95% CI: 0.20-2.80] p=0.675). Average complete protection time (CPT) of MAÏA® and that of DEET was similar for each of the mosquito strains: 571.6 minutes (95% CI: 558.3-584.8) vs 575.0 minutes (95% CI: 562.1-587.9) against An. gambiae; 585.6 minutes (95% CI: 571.4-599.8) vs 580.9 minutes (95% CI: 571.1-590.7) against An. arabiensis; 444.1 minutes (95% CI: 401.8-486.5) vs 436.9 minutes (95% CI: 405.2-468.5) against Ae. aegypti.Conclusions: MAÏA® repellent ointment provides complete protection for 9 hours against both An. gambiae and An. arabiensis, and 7 hours against Ae. aegypti similar to 20% DEET (in ethanol). MAÏA® repellent ointment can be recommended to be used as a tool for prevention of outdoor biting mosquitoes in tropical locations as it protects for more than 6 hours.


2019 ◽  
Vol 4 ◽  
pp. 11
Author(s):  
Sunisa Sawasdichai ◽  
Victor Chaumeau ◽  
Tee Dah ◽  
Thithiworada Kulabkeeree ◽  
Ladda Kajeechiwa ◽  
...  

Background: Natural Wolbachia infections in malaria mosquitoes were recently reported in Africa, and negatively correlated with the development of Plasmodium falciparum in the vectors. The occurrence and effects of Wolbachia infections outside Africa have not been described and may have been underestimated. Methods: Mosquitoes were collected by human-landing catch during May and June 2017 in ten villages in Kayin state, Myanmar. Closely related species of malaria vectors were identified with molecular assays. Wolbachia infection rates were assessed with quantitative real-time PCR. Results: Low titer of Wolbachia DNA was detected in 13/370 samples in six malaria vector species. Phylogenetic analysis based on 16S rRNA sequences revealed a high diversity of Wolbachia strains and identified lineages different from those described in the African malaria mosquitoes. Conclusion: These low-density genetically diverse natural Wolbachia infections question the ecology and biology of Wolbachia-Anopheles interactions in Southeast Asia. Their effects on malaria transmission and mosquito vectors are yet to be determined.


Author(s):  
Arum Triyas Wardani ◽  
RA. Wigati ◽  
Esti Rahardianingtyas ◽  
Rendro Wianto ◽  
Arief Nugroho

Dengue Hemorrhagic Fever (DHF) is a vector-borne disease that is still a health problem in Indonesia. One of the DHF control effort is to control the larvae of the mosquito vector using Bacillus thuringensis H-14. The weakness of this metode is its short residual effect.  This study aims to determine differences in the effectiveness of B. thuringiensis H-14 tested in two different water sources, namely well water and PDAM water in people's houses and its residual effects in the field. The study used a quasi-​experimental, which include laboratory and field experiments in March to September 2017. The research was carried out by producing B. thuringensis H-14 Salatiga isolates in the form of slow release tablets, testing the efficacy and measuring their effectiveness to Aedes aegypti mosquito larvae in two kinds of water sources. The results showed that the content of B. thuringiensis Salatiga isolate in slow release tablets weighing 125 mg was 5 mg. The efficacy test at laboratory scale showed that the LC50 was 0.436 ppm and the LC90 was 2.440 ppm. The effectiveness test in the field of LC50 (PDAM water) is 0.098 ppm and (well water) is 1.909 ppm, while LC90 (PDAM water) is 0.186 ppm and (well water) is 0.909 ppm. The efficacy assay results showed there was no significant difference in the effect of B. thuringiensis tablet between well water and PDAM water. B. thuringiensis H-14 tablets were effective in controlling Ae. aegypti larvae more than 80% until the 7th day in field testing.


2020 ◽  
Author(s):  
Sebastien Marcombe ◽  
Santi Maithaviphet ◽  
Julie Bobichon ◽  
Nothasin Phommavan ◽  
Simone Nambanya ◽  
...  

Abstract Background . In Laos, the malaria burden remains high despite a significant reduction of cases during the last decade. In the context of the disease elimination by 2030, a nationwide entomological survey was conducted to better understand the distribution, abundance and behavior of major malaria vectors ( Anopheles spp.) in the country. Methods . Mosquito collections were implemented in ten villages from ten provinces during the rainy and dry seasons of 2014 and 2015 by using human landing catch (HLC) and cow bait collection (CBC) methods. After morphological identification in the field, molecular identification of the sibling species of Anopheles mosquitoes from the Funestus, Leucosphyrus, and Maculatus groups were determined using PCR specific alleles. A screening of Plasmodium falciparum and P. vivax infections in the vectors was carried out by quantitative PCR assays. Results. A total of 14,146 adult mosquitoes representing 25 different Anopheles species were collected and morphologically identified. Molecular identification revealed the presence of 12 sibling species within the main primary vector groups including An. maculatus s.s., An. rampae , An. sawadwongporni , An. pseudowillmori , An. dravidicus , An. minimus s.s., An. aconitus , An. pampanai , An. harrisoni , An. dirus s.s., An. baimaii , An. nemophilous . Anopheles maculatus and An. minimus were predominant during both the dry and rainy seasons, but showed highly zoophilic preferences (Zoophilic index of 98% and 95%, respectively). Overall, 22% of the total malaria vectors were collected between 10:00 PM and 5:00 AM indoors when people are sleeping. Twenty-seven percent of primary and secondary vectors were collected outdoors before 10:00 PM or after 5:00 AM, times when people are usually awake and outdoors. Only two specimens were positive for P. falciparum , one An. aconitus from Phongsaly and one An. minimus from Vientiane Province Conclusions. The results indicate that people living in rural areas in Laos are constantly exposed to malaria vectors throughout the year and specifically outdoors. The use of LLINs/IRS remains important but innovative tools and new strategies are needed to address locally, the early and outdoor malaria transmission. Lack of expertise in general entomological methods may further exacerbate the situation.


Sign in / Sign up

Export Citation Format

Share Document