An Electrochemically Reduced Copper/Reduced Graphene Oxide Film Modified Electrode for Sensitive Non-Enzymatic Glucose Detection in Human Serum

Author(s):  
Sopit Phetsang ◽  
Pinit Kidkhunthod ◽  
Narong Chanlek ◽  
Jaroon Jakmunee ◽  
Pitchaya Mungkornasawakul ◽  
...  

Abstract Numerous studies suggest that modification with functional nanomaterials can enhance the electrode electrocatalytic activity, sensitivity, and selectivity of the electrochemical sensors. Here, a highly sensitive and cost-effective disposable non-enzymatic glucose sensor based on copper(II)/reduced graphene oxide modified screen-printed carbon electrode is demonstrated. Facile fabrication of the developed sensing electrodes is carried out by the adsorption of copper(II) onto graphene oxide modified electrode, then following the electrochemical reduction. The proposed sensor illustrates good electrocatalytic activity toward glucose oxidation with a wide linear detection range from 0.10 mM to 12.5 mM, low detection limit of 65 µM, and high sensitivity of 172 µA mM− 1 cm− 2 along with satisfactory anti-interference ability, reproducibility, stability, and the acceptable recoveries for the detection of glucose in a human serum sample (95.6–106.4%). The copper(II)/reduced graphene oxide based sensor with the superior performances is a great potential for the quantitation of glucose in real samples.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Sopit Phetsang ◽  
Pinit Kidkhunthod ◽  
Narong Chanlek ◽  
Jaroon Jakmunee ◽  
Pitchaya Mungkornasawakul ◽  
...  

AbstractNumerous studies suggest that modification with functional nanomaterials can enhance the electrode electrocatalytic activity, sensitivity, and selectivity of the electrochemical sensors. Here, a highly sensitive and cost-effective disposable non-enzymatic glucose sensor based on copper(II)/reduced graphene oxide modified screen-printed carbon electrode is demonstrated. Facile fabrication of the developed sensing electrodes is carried out by the adsorption of copper(II) onto graphene oxide modified electrode, then following the electrochemical reduction. The proposed sensor illustrates good electrocatalytic activity toward glucose oxidation with a wide linear detection range from 0.10 mM to 12.5 mM, low detection limit of 65 µM, and high sensitivity of 172 μA mM–1 cm–2 along with satisfactory anti-interference ability, reproducibility, stability, and the acceptable recoveries for the detection of glucose in a human serum sample (95.6–106.4%). The copper(II)/reduced graphene oxide based sensor with the superior performances is a great potential for the quantitation of glucose in real samples.


RSC Advances ◽  
2018 ◽  
Vol 8 (57) ◽  
pp. 32565-32573 ◽  
Author(s):  
Shaojun Yang ◽  
Daliang Liu ◽  
Qing Bo Meng ◽  
Shuyao Wu ◽  
Xi-Ming Song

A novel electrochemical glucose sensor based on methylene blue-reduced graphene oxide nanocomposite was constructed, and the sensor exhibited good glucose oxidase-mimetic electrocatalytic activity towards glucose and practical applicability.


Author(s):  
Medha Gijare ◽  
◽  
Sharmila Chaudhari ◽  
Satish Ekar ◽  
Anil Garje ◽  
...  

2020 ◽  
Vol 12 (8) ◽  
pp. 1125-1136
Author(s):  
Rupali Waichal ◽  
Ashwini Bhirud ◽  
H. Fouad ◽  
Suresh Gosavi ◽  
Muthupandian Ashokkumar

Reduced Graphene oxide (RGO) decorated with Ni nanoparticles (NiNPs) composites, have been successfully synthesized using a simple hydrothermal method and possessing excellent electrocatalytic activity towards glucose oxidation. The morphological and structural features of RGO-Ni nanocomposites were characterized by field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and energy dispersive spectroscopy (EDS). From TEM, we observed that NiNPs were anchored on RGO sheets. Cyclic Voltammetric (CV) study revealed that the electrocatalytic activity of RGO-Ni nanocomposite with 20% Ni loading (RGONi-20) towards glucose oxidation is better than that shown by bare Glassy Carbon Electrode (GCE), RGO, bare NiNPs, RGONi10 and RGONi-30. The prepared nanocomposites exhibited fast electrocatalytic response (<5 s) towards glucose oxidation. Amperometric study indicates that the present glucose sensor have exhibited excellent performance by offering a lowest detection limit as 5.1 μM, with linier range from 2 to 5000 μM and high sensitivity of 896.67 μA mM–1 cm–2. Interference from different anticipatable electroactive substances such as ascorbic acid (AA), uric acid (UA) and dopamine (DA) is not observed. Furthermore, the application of the as prepared sensor was successfully demonstrated for the detection of glucose in human serum and results were compa- rable to presently used nonenzymatic technique. RGONi-20 nanocomposite electrode holds great promise for the development of biosensors and other electrochemical devices.


2019 ◽  
Vol 9 (4) ◽  
pp. 622 ◽  
Author(s):  
Cheng-You Liu ◽  
Yi-Chieh Chou ◽  
Jui-Hsuan Tsai ◽  
Tzu-Ming Huang ◽  
Jian-Zhang Chen ◽  
...  

Tyrosinase, chitosan, and reduced graphene oxide (rGO) are sequentially used to modify a screen-printed carbon electrode (SPCE) for the detection of dopamine (DA), without interference from uric acid (UA) or ascorbic acid (AA). The use of tyrosinase significantly improves the detection’s specificity. Cyclic voltammetry (CV) measurements demonstrate the high sensitivity and selectivity of the proposed electrochemical sensors, with detection limits of 22 nM and broad linear ranges of 0.4–8 μM and 40–500 μM. The fabricated tyrosinase/chitosan/rGO/SPCE electrodes achieve satisfactory results when applied to human urine samples, thereby demonstrating their feasibility for analyzing DA in physiological samples.


Nanomaterials ◽  
2019 ◽  
Vol 9 (1) ◽  
pp. 115 ◽  
Author(s):  
Quanguo He ◽  
Yiyong Wu ◽  
Yaling Tian ◽  
Guangli Li ◽  
Jun Liu ◽  
...  

A new electrochemical sensor for nanomolar rutin detection based on amine-functionalized Fe3O4 nanoparticles and electrochemically reduced graphene oxide nanocomposite modified glassy carbon electrode (NH2-Fe3O4 NPs-ErGO/GCE) was fabricated through a simple method, and the X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscope (SEM), transmission electron microscope (TEM), vibrating sample magnetometer (VSM) and electrochemical technique were used to characterize the modified electrode. The electrochemical behavior of rutin on the Fe3O4 NPs-ErGO/GCE was studied in detail. The electrochemical response of rutin at this modified electrode was remarkably higher than that of the bare GCE or other modified GCE (GO/GCE, Fe3O4 NPs-GO/GCE, and ErGO/GCE). Under the optimum determination conditions, Fe3O4 NPs-ErGO/GCE provided rutin with a broader detection range of 6.0 nM–0.1 µM; 0.1–8.0 µM and 8.0–80 µM, a minimum detectable concentration of 4.0 nM was obtained after 210 s accumulation. This novel method was applied in determination of rutin in pharmaceutical tablets and urine samples with satisfactory results.


2021 ◽  
Vol 20 (02) ◽  
pp. 2150020
Author(s):  
Vijay Kumar Anand ◽  
Kapil Bhatt ◽  
Sandeep Kumar ◽  
B. Archana ◽  
Sandeep Sharma ◽  
...  

In this paper, we report the preparation and characterization of a sensitive and reusable nonenzymatic glucose (NEG) sensor based on copper nanowires (CuNWs)/polyaniline (PANI)/reduced graphene oxide (rGO) nanocomposite ink. The CuNWs/PANI/rGO nanocomposite ink was prepared by solvothermal mixing of CuNWs, PANI, rGO and binders. The X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), Fourier Transform Infra-Red (FT-IR) spectroscopy techniques were used to assess the structural and morphological parameters of prepared nanocomposite ink. The cyclic voltammetry (CV) technique was used to estimate the electrochemical behavior of prepared NEG sensor. The structural, morphological and spectroscopy results confirmed the change in morphological and oxidation state of CuNWs to CuO nanostructures as a constituent of nanocomposite ink. The CuO nanostructures supported on PANI/rGO demonstrated good electrochemical stability and great electrocatalytic activity toward glucose oxidation. At a glucose oxidation potential of 0.64V, the prepared NEG sensor exhibited great electrocatalytic ability by offering a high sensitivity of 843.06[Formula: see text]AmM[Formula: see text]cm[Formula: see text] in the linear glucose range 0–4mM with a lower detection limit of 1.6mM. In addition to these outstanding performance characteristics, CuNWs/PANI/rGO nanocomposite ink-based NEG sensor has the advantages of ease of fabrication, low cost and reusability.


2019 ◽  
Vol 35 (7) ◽  
pp. 739-743 ◽  
Author(s):  
Sima POURBEYRAM ◽  
Maryam SOLTANPOUR ◽  
Soghra FATHALIPOUR

2020 ◽  
Vol 16 (8) ◽  
pp. 996-1009
Author(s):  
Khadijeh Ghanbari ◽  
Ashraf Sivandi

Background: Hypertension is a major risk for morbidity and mortality, while hypertension is associated with cardiovascular disease and organ damage. Recent research efforts have focused on the development of highly selective angiotensin receptor blockers. In which losartan (LOS) is considered as a new generation of an effective oral drug product against arterial hypertension. Therefore, the determination of drugs in biological fluids, pharmaceuticals (tablets), and wastewater is of critical importance for clinical applications, forensics, quality control, and environmental protection that call for the development of analytical methods. Many ranges of methods such as spectroscopic methods and chromatographic techniques have been developed to determine LOS in pharmaceutical formulations and biological fluids. However, there are crucial interference problems in these methods. For these reasons, more sensitive, desirable, portable, low-cost, simple, and selective nanocomposite-based sensors are needed in terms of health safety. Nanomaterials such as reduced graphene oxide, chitosan, and metal nanoparticles are used to improve the sensitivity in the development of electrochemical sensors. Objective: In this study, a novel reduced graphene oxide (RGO), chitosan (Chit), gold (Au), and zinc oxide (ZnO) nanocomposite (RGO/Chitosan/Au/ZnO) was synthesized and used to develop a sensitive and efficient electrochemical sensor for LOS detection. Methods: Modification of electrode by RGO/Chit/Au/ZnO nanocomposite was performed in four stages with GO (at -2.0 V for 150 s), Chitosan (at -3.0 V for 300 s), Au nanoparticles (at -0.4 V for 400 s), and Zn nanoflowers like (at -0.7 V for 1200 s). The RGO/Chitosan/Au/ZnO nanocomposite was characterized by field emission scanning electron microscopy (FE-SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FT-IR). Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) were used to detect LOS, and the influence of pH value, scan rate, accumulation potential, and time also losartan concentration on the performance of ZnO/Au/Chitosan/RGO/GCE were investigated. In order to investigate the selectivity of the modified electrode for the determination of LOS, the effect of possible interfering species was evaluated and showed that these species are not interferences. Also, the reproducibility of the modified electrode was investigated and implying that the RGO/Chit/Au/ZnO nanocomposite was highly reproducible. Results: The modified electrode was used as a sensor for the selective and sensitive determination of LOS with a detection limit of 0.073 μM over the dynamic linear range of 0.5μM to 18.0 μM. In addition, electrochemical oxidation of LOS was well recovered in pharmaceutical formulations. Conclusion: LOS is used to treat high blood pressure, taking into account the oxidation of this compound, the use of electrochemical based sensors, ideally suited to a specific chemical species, can be fully selectable and High-sensitivity answer is very important. In this study, the electrodes with RGO/Chit/Au/ZnO nanocomposite were modified by the electrochemical method. Nanocomposites were characterized by various methods such as FE-SEM, FT-IR, XRD, Raman, and XPS. The electrocatalytic activity of the modified electrode was then investigated for measuring LOS. According to the results of the modified electrode, high sensitivity, reproducibility, and selectivity have been shown to oxidize this composition.


Sign in / Sign up

Export Citation Format

Share Document