Optimization, Alternative Materials and Improvements in Body Armor Shields

2007 ◽  
Author(s):  
R. C. Batra ◽  
G. M. Zhang ◽  
J. Zheng ◽  
G. Gopinath
Author(s):  
Deepak D. ◽  
Nitesh Kumar ◽  
Shreyas P. Shetty ◽  
Saurabh Jain ◽  
Manoj Bhat

The expensive nature of currently used materials in the soft robotic industry demands the consideration of alternative materials for fabrication. This work investigates the performance of RTV-2 grade silicone rubber for fabrication of a soft actuator. Initially, a cylindrical actuator is fabricated using this material and its performance is experimentally assessed for different pressures. Further, parametric variations of the effect of wall thickness and inflation pressure are studied by numerical methods. Results show that, both wall thickness and inflation pressure are influential parameters which affect the elongation behaviour of the actuator. Thin (1.5 mm) sectioned actuators produced 76.97% more elongation compared to thick sectioned, but the stress induced is 89.61 % higher. Whereas, the thick sectioned actuator (6 mm) showed a higher load transmitting capability. With change in wall thickness from 1.5 mm to 6 mm, the elongation is reduced by 76.97 %, 38.35 %, 21.05 % and 11.43 % at pressure 100 kPa, 75 kPa, 50 kPa and 25 kPa respectively. The induced stress is also found reduced by 89.61 %, 86.66 %, 84.46 % and 68.68 % at these pressures. The average load carrying capacity of the actuator is found to be directly proportional to its wall thickness and inflation pressure.


Alloy Digest ◽  
1997 ◽  
Vol 46 (8) ◽  

Abstract Project 70 and Project 7000 Type 203 stainless steels are alternative materials to AISI Type 303, resulfurized stainless steel having improved machinability. High manganese and copper are substituted for some nickel resulting in a stable austenitic structure having low magnetic permeability. This datasheet provides information on composition, physical properties, hardness, elasticity, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating, and joining. Filing Code: SS-505. Producer or source: Carpenter. Originally published May 1989, revised August 1997.


2012 ◽  
Author(s):  
Igor Luzinov ◽  
Konstantin G. Komev
Keyword(s):  

Nanomaterials ◽  
2019 ◽  
Vol 9 (10) ◽  
pp. 1406 ◽  
Author(s):  
Yasmin Ranjous ◽  
Géza Regdon ◽  
Klára Pintye-Hódi ◽  
Tamás Varga ◽  
Imre Szenti ◽  
...  

Recently, there has been an increasing interest in the application of nanotubular structures for drug delivery. There are several promising results with carbon nanotubes; however, in light of some toxicity issues, the search for alternative materials has come into focus. The objective of the present study was to investigate the influence of the applied solvent on the composite formation of titanate nanotubes (TNTs) with various drugs in order to improve their pharmacokinetics, such as solubility, stability, and bioavailability. Composites were formed by the dissolution of atenolol (ATN) and hydrochlorothiazide (HCT) in ethanol, methanol, 0.01 M hydrochloric acid or in ethanol, 1M sodium hydroxide, dimethylformamide (DMF), dimethyl sulfoxide (DMSO), respectively, and then they were mixed with a suspension of TNTs under sonication for 30 min and vacuum-dried for 24 h. The structural properties of composites were characterized by SEM, TEM, FT-IR, differential scanning calorimetry (DSC), thermogravimetric (TG) analysis, and optical contact angle (OCA) measurements. Drug release was determined from the fast disintegrating tablets using a dissolution tester coupled with a UV–Vis spectrometer. The results revealed that not only the good solubility of the drug in the applied solvent, but also the high volatility of the solvent, is necessary for an optimal composite-formation process.


Author(s):  
Yuksel Palaci ◽  
Mustafa M Arikan

This study investigates visualization of optimized layer thickness with a ternary diagram by considering Volume, Weight, and Cost priorities to determine the composite structure of alternative ceramics to use in body armor application by using the Digital Logic Method (DLM). Three criterion priorities (volume, weight, cost) have been investigated to help designers decide on optimum ceramic material for their applications. Alumina (Al2O3), silicon carbide (SiC), silicon nitride (Si3N4), and boron carbide (B4C) were analyzed and ranked to decide for material selection based on priorities. The analysis results showed that silicon nitride (Si3N4) had the maximum performance index (PI) point (80.0) based on the volume priority. On the other hand, while boron carbide (B4C) had the maximum PI point (76.4) in terms of the weight priority, alumina (Al2O3) was determined to be the best material according to the cost priority. PI point of alumina (Al2O3) was calculated as 100. A ternary diagram was developed for decision-makers to visualize material selection performances. The optimization of the ceramic composite layer thickness of the alternative ceramic materials is visualized by considering three criteria.


Sign in / Sign up

Export Citation Format

Share Document