scholarly journals Surface modification of vascular endothelial growth factor-loaded silk fibroin to improve biological performance of ultra-high-molecular-weight polyethylene via promoting angiogenesis

2017 ◽  
Vol Volume 12 ◽  
pp. 7737-7750 ◽  
Author(s):  
Chengchong Ai ◽  
Dandan Sheng ◽  
Jun Chen ◽  
Jiangyu Cai ◽  
Siheng Wang ◽  
...  
RSC Advances ◽  
2018 ◽  
Vol 8 (27) ◽  
pp. 15158-15165
Author(s):  
Dongliang Zhang ◽  
Nailong Cao ◽  
Shukui Zhou ◽  
Zhong Chen ◽  
Xinru Zhang ◽  
...  

The adipose derived stem cells (ADSCs) was composited with vascular endothelial growth factor (VEGF)-silk fibroin (SF) nanospheres-bladder acellular matrix graft (BAMG) scaffold to repair bladder defect in rabbits.


2008 ◽  
Vol 54 (7) ◽  
pp. 1218-1225 ◽  
Author(s):  
Sigrun M Gustafsdottir ◽  
Stefan Wennström ◽  
Simon Fredriksson ◽  
Edith Schallmeiner ◽  
Andrew D Hamilton ◽  
...  

Abstract Background: Improved methods are required to screen drug candidates for their influences on protein interactions. There is also a compelling need for miniaturization of screening assays, with attendant reductions in reagent consumption and assay costs. Methods: We used sensitive, miniaturized proximity ligation assays (PLAs) to monitor binding of vascular endothelial growth factor A (VEGF-A) to 2 of its receptors, VEGFR-1 and VEGFR-2. We measured the effects of proteins and low molecular weight compounds capable of disrupting these interactions and compared the results with those obtained by immunoblot analysis. We analyzed 6 different inhibitors: a DNA aptamer, a mixed DNA/RNA aptamer, a monoclonal VEGF-A neutralizing antibody, a monoclonal antibody directed against VEGFR-2, a recombinant competitive protein, and a low molecular weight synthetic molecule. Results: The PLAs were successful for monitoring the formation and inhibition of VEGF-A–receptor complexes, and the results correlated well with those obtained by measuring receptor phosphorylation. The total PLA time is just 3 hours, with minimal manual work and reagent additions. The method allows evaluation of the apparent affinity [half-maximal inhibitory concentration (IC50)] from a dose–response curve. Conclusions: The PLA may offer significant advantages over conventional methods for screening the interactions of ligands with their receptors. The assay may prove useful for parallel analyses of large numbers of samples in the screening of inhibitor libraries for promising agents. The technique provides dose–response curves, allowing IC50 values to be calculated.


Sign in / Sign up

Export Citation Format

Share Document