Deemulsification of Water-in-Oil Emulsion with Sludges

1987 ◽  
Vol 22 (3) ◽  
pp. 437-443 ◽  
Author(s):  
N. Kosaric ◽  
Z. Duvnjak

Abstract Aerobic sludge from a municipal activated sludge treatment plant, sludge from a conventional municipal anaerobic digester, aerobic sludge from an activated sludge process of a petroleum refinery, and granular sludge from an upflow sludge blanket reactor (USBR) were tested in the deemulsification of a water-in-oil emulsion. All sludges except the last one, showed a good deemulsification capability and could he used for a partial deemulsification of such emulsions. The rate and degree of the deemulsifications increased with an increase in sludge concentrations. The deemulsifications were faster at 85°C and required smaller amounts of sludge than in the case of the deemulsifications at room temperature. An extended stirring (up to a certain limit) in the course of the dispersion of sludge emulsion helped the deemulsification. Too vigorous agitation had an adverse effect. The deemulsification effect of sludge became less visible with an increase in the dilution of emulsion which caused an increase in its spontaneous deemulsification.

2006 ◽  
Vol 54 (3) ◽  
pp. 89-94 ◽  
Author(s):  
R. Cantusio Neto ◽  
J.U. Santos ◽  
R.M.B. Franco

Among many waterborne diseases the giardiasis and cryptosporidiosis are of particular public health interest, because Giardia cysts and Cryptosporidium oocysts can persist for long periods in the environment, and both pathogenic protozoa have been implicated as the cause of many outbreaks of gastroenteritis in the last 25 years. In order to evaluate the efficiency of cysts and oocysts' removal by the activated sludge process, and by UV reactor in inactivating cysts and oocysts in one wastewater treatment plant (WWTP) of Campinas, three sampling points were selected for study: (1) influent, (2) treated effluent without UV disinfection and (3) treated effluent with UV disinfection. Giardia spp. cysts prevailed with higher density in the three different sample types. Cryptosporidium spp. oocysts were observed in only two samples of influent and just one sample of treated sewage with UV disinfection. In the animal infectivity assay for Giardia spp, one mouse of the UV treated group revealed trophozoites in intestinal scrapings. The results of the present study indicate that treatment by activated sludge process delivered a reduction of 98.9% of cysts and 99.7% of oocysts and UV disinfection was not completely efficient regarding the inactivation of Giardia cysts in the case of the WWTP studied.


2017 ◽  
Vol 1 ◽  
pp. 1
Author(s):  
Zhan Yang

Activated sludge process is the most widely used technology in sewage bioremediation up to now. However, there is also a serious problem with this technology, that is, a great amount of sludge will be left over. In view of this situation, a study has been carried out through the domestic activated technology for sludge treatment and also research on the effective sludge treatment. They made use of the microbial decomposition to decompose the oxide by using the means of physical, chemical, biological, etc. to minimize the effluent from the sewage treatment plant and thus, reduced the amount of sludge produced.


1992 ◽  
Vol 25 (4-5) ◽  
pp. 151-160 ◽  
Author(s):  
M. Kos ◽  
J. Wanner ◽  
I. Šorm ◽  
P. Grau

The modification of denitrification - nitrification activated sludge process with reaeration of concentrated returned sludge was tested in pilot units with municipal wastewaters at the Prague wastewater treatment plant. The ability of the R-D-N Process to increase the aerobic sludge age with a reduced volume demand was verified. The sludge settling properties were evaluated and the effect of recirculation, simultaneous denitrification and compartmentalization of the denitrification zone was studied. Optimum design parameters of the R-D-N process are suggested.


2017 ◽  
Vol 1 (1) ◽  
pp. 1
Author(s):  
Zhan Yang

Activated sludge process is the most widely used technology in sewage bioremediation up to now. However, there is also a serious problem with this technology, that is, a great amount of sludge will be left over. In view of this situation, a study has been carried out through the domestic activated technology for sludge treatment and also research on the effective sludge treatment. They made use of the microbial decomposition to decompose the oxide by using the means of physical, chemical, biological, etc. to minimize the effluent from the sewage treatment plant and thus, reduced the amount of sludge produced.


2016 ◽  
Vol 9 (2) ◽  
Author(s):  
Dinda Rita K. Hartaja ◽  
Imam Setiadi

Generally, wastewater of nata de coco industry contains suspended solids and COD were high, ranging from 90,000 mg / l. The high level of of the wastewater pollutants, resulting in nata de coco industry can not be directly disposed of its wastewater into the environment agency. Appropriate technology required in order to process the waste water so that the treated water can meet the environmental quality standards that are allowed. Designing the waste water treatment plant that is suitable and efficient for treating industrial wastewater nata de coco is the activated sludge process. Wastewater treatment using activated sludge process of conventional (standard) generally consists of initial sedimentation, aeration and final sedimentation.Keywords : Activated Sludge, Design, IPAL


2008 ◽  
Vol 3 (1) ◽  
Author(s):  
Young H. Yoon ◽  
Jae R. Park ◽  
Sang W. Ahn ◽  
Kwang B. Ko ◽  
Kyung J. Min ◽  
...  

Hybrid Activated Sludge Process (HASP) with IMET was developed and applied to an activated sludge process for the advanced nutrient treatment in Korea. The characteristics of nitrogen removal from the HASP were investigated through a kinetic study by batch-type experiment. Online DB analysis produced from the IMET was conducted for the nutrient removal performance in the field demonstration plant treating 10,000 m3/day in G city of Korea. In this paper, we aimed to determine the effect of increasing NHM4+-N load on the specific nitrification rate (SNR) and the specific denitrification rate (SDNR) through a batch-type experiment, and to estimate the net reaction time for the phase-transfer rate using online DB analysis in the HASP operation. Experimental results include: (1) both the nitrification and denitrification followed first-order kinetics; (2) the maximum SNR and SDNR were 4.0301 mgN/gVSS·hr and 2.785 mgN/gVSS·hr, respectively; (3) comparison of reaction rates between nitrification and denitrification from the non-linear regression analysis found that nitrification rate was higher than denitrification.


1970 ◽  
Vol 5 (1) ◽  
pp. 34-54
Author(s):  
Shyam D. Bokil ◽  
Jatinder K. Bewtra

Abstract Nine sets of batch experiments, each of ten to twelve days duration, were conducted in the laboratory on return-sludge samples collected from activated sludge treatment plant at Windsor. The thickened sludge samples were blended daily in a waring blender and were continuously aerated in twelve-litres capacity jars. Parallel runs were made on control sludge samples which were not blended. Amongst the parameters varied were the speed and frequency of blending and the aeration rate. The effects of these variables on progressive bio-degradation of volatile suspended solids and the settling characteristics of the sludge were determined. Blended sludge showed significant improvement in the rate of bio-degradation and its settling characteristics as compared to the control unblended sludge


1990 ◽  
Vol 22 (7-8) ◽  
pp. 131-138
Author(s):  
Ahmed Fadel

Many of Egypt's cities have existing treatment plants under operation that have been constructed before 1970. Almost all of these treatment plants now need rehabilitation and upgrading to extend their services for a longer period. One of these plants is the Beni Suef City Wastewater Treatment Plant. The Beni Suef WWTP was constructed in 1956. It has primary treatment followed by secondary treatment employing intermediate rate trickling filters. The BOD, COD, and SS concentration levels are relatively high. They are approximately 800, 1100, and 600 mg/litre, respectively. The Beni Suef city required the determination of the level of work needed for the rehabilitation and upgrading of the existing 200 l/s plant and to extend its capacity to 440 l/s at year 2000 A description of the existing units, their deficiencies and operation problems, and the required rehabilitation are presented and discussed in this paper. Major problems facing the upgrading were the lack of space for expansion and the shortage of funds. It was, therefore, necessary to study several alternative solutions and methods of treatment. The choice of alternatives was from one of the following schemes: a) changing the filter medium, its mode of operation and increasing the number of units, b) changing the trickling filter to high rate and combining it with the activated sludge process, for operation by one of several possible combinations such as: trickling filter-solids contact, roughing filter-activated sludge, and trickling filter-activated sludge process, c) dividing the flow into two parts, the first part to be treated using the existing system and the second part to be treated by activated sludge process, and d) expanding the existing system by increasing the numbers of the different process units. The selection of the alternative was based on technical, operational and economic evaluations. The different alternatives were compared on the basis of system costs, shock load handling, treatment plant operation and predicted effluent quality. The flow schemes for the alternatives are presented. The methodology of selecting the best alternative is discussed. From the study it was concluded that the first alternative is the most reliable from the point of view of costs, handling shock load, and operation.


1988 ◽  
Vol 20 (11-12) ◽  
pp. 131-136 ◽  
Author(s):  
A. D. Wong ◽  
C. D. Goldsmith

The effect of discharging specific oil degrading bacteria from a chemostat to a refinery activated sludge process was determined biokinetically. Plant data for the kinetic evaluation of the waste treatment plant was collected before and during treatment. During treatment, the 500 gallon chemostatic growth chamber was operated on an eight hour hydraulic retention time, at a neutral pH, and was fed a mixture of refinery wastewater and simple sugars. The biokinetic constants k (days−1), Ks (mg/L), and K (L/mg-day) were determined before and after treatment by Monod and Lineweaver-Burk plots. Solids discharged and effluent organic concentrations were also evaluated against the mean cell retention time (MCRT). The maximum utilization rate, k, was found to increase from 0.47 to 0.95 days−1 during the operation of the chemostat. Subsequently, Ks increased from 141 to 556 mg/L. Effluent solids were shown to increase slightly with treatment. However, this was acceptable due to the polishing pond and the benefit of increased ability to accept shock loads of oily wastewater. The reason for the increased suspended solids in the effluent was most likely due to the continual addition of bacteria in exponential growth that were capable of responding to excess substrate. The effect of the chemostatic addition of specific microbial inocula to the refinery waste treatment plant has been to improve the overall organic removal capacity along with subsequent gains in plant stability.


1989 ◽  
Vol 21 (10-11) ◽  
pp. 1161-1172 ◽  
Author(s):  
M. Hiraoka ◽  
K. Tsumura

The authors have been developing a hierarchical control system for the activated sludge process which consists of an upper level system controlling long-term seasonal variations, a control system of intermediate level aiming at optimization of the process and a control system of lower level controlling diurnal changes or hourly fluctuations. The control system using the multi-variable statistical model is one of the most appropriate control systems based on the modern control theory, for applying the lower level control of the activated sludge process. This paper introduces our efforts for developing the reliable data acquisition system, the control experiments applying the AR-model, one of the statistical models which were conducted at a pilot plant and present studies on the system identification and control at a field sewage treatment plant.


Sign in / Sign up

Export Citation Format

Share Document