Operational Experiences with the Industrial and Communal Waste Water Treatment System in the District of Linz

1990 ◽  
Vol 22 (5) ◽  
pp. 87-92 ◽  
Author(s):  
Gerd E. Reichel

The waste water treatment system of the central region Linz is described. Because of the construction of the hydroelectric plant in Abwinden-Asten a central sewage treatment plant for 22 communities and the waste waters of the chemical and steel industry was constructed. Purification efficiency in terms of BOD5 is 93 % and 83 % for COD. The anaerobic digested sludge is deposited in lagoons.

Author(s):  
Mohd Abul Hasan

Abstract The treatment of wastewater is an essential factor in preventing pollutants and promoting the quality of the water. The inherent complexity, influential impact and the solid waste infrastructure lead to confusion and variance in the primary clarifier for wastewater. These inconsistencies lead to variations in the purity and capacity constraints of wastewater and the existential impact of water receipt. The water treatment is a complicated task that has means of chemical, technical & biochemical influences. A credible ANN method is necessary for another waste water treatment plant to prevent the breakdown of the processes. Virtual reality seems to have become a strong solution for preventing waste management uncertainties and problems. This is not only due to high deformations but also to significant external disturbances that water systems are controlling challenges. Climate is among the most significant of such disturbances. Various environmental conditions actually include different influx frequencies and levels of substances. Water contamination has become one of the extremely serious growing conservation; sewage treatment plant identification is a key major issue here and the agencies enforce tighter requirements for the operating of wastewater software systems. This article plans to create models of achievement and prospects for the possible future guidance of recent research borders for the use of artificial intelligence in wastewater treatment plants which concurrently deal with pollutants. This study has shown us that the composite ANN provides a greater level of competence in plant prediction and systemization. Highlight Systematize of Wastewater Utilization Plants, Artificial Neural Networks, artificial intelligence, Prediction Analysis, Reliability.


Author(s):  
Uday Bhan Prajapati ◽  
Arun Lal Srivastav ◽  
Shiraz A.Wajih

In present study, an evaluation of ZESTP (Zero Energy Sewage Treatment Plant) has been described as an alternative solution of sewage water treatment. This system has become widely famous because of having great absorption efficiencyof nutrients, simple construction and maintenance, relatively less costly as well as a strong process. After treatment of sewage water, the level of dissolve oxygen was increased up to 73% due to the enhanced numbers of photosynthetic organisms. Some aquatic macrophytes such as Eichhornia crassipes (Mart.) Solms, Pistia stratiotes L. and Hydrilla verticillata Casp were used in ZESTP for waste water treatment based on phytoremediation. ZESTP could reduce the around 84% turbidity, 46% electrical conductivity, 43% salinity, 74% acidity, 69% free CO2, 73% BOD, 44% COD, 70% suspended solids, 62% total hardness, 71% chloride, 59% cadmium, 51% iron, and 71% copper from the waste water. Naturally, some plants have capability are to retain and/or remove fatal chemicals which are present in sewage water. Moreover, macrophytes based ZESTP is a cost effective and an eco-friendly technique of sewage water treatment.


2012 ◽  
Vol 39 (2) ◽  
pp. 147-156 ◽  
Author(s):  
Hamida Khanum ◽  
Sharmili Shanjida Khanam ◽  
Masuma Sultana ◽  
Md. Hafiz Uddin ◽  
Ripon Chandra Dhar ◽  
...  

The present study was designed for the qualitative and quantitative detection of Giardia in the Pagla Sewage Treatment Plant (PSTP) in Dhaka. The physico-chemical parameters of the sewage water were also recorded. Total 72 raw and treated samples were collected from PSTP throughout the year 2008 and these were processed with the Formol-Ether Concentration method and IMS followed by microscopy to identify Giardia in the sewage water. The protozoan parasite Giardia was abundant (2.23±1.44 × 105 cyst/l) in the sewage water dominating the sampling sites-Grit chamber (44%), Measuring chamber (34%) and Outlet lagoon (38%). A low abundance of Giardia in the PSTP starting from the first point to the last one indicates the waste water treatment efficiency for removal of the pathogen. A significant correlation was found for log (number of Giardia +1) with turbidity (r= 0.729) and TDS (r= 0.536) at 0.01level.DOI: http://dx.doi.org/10.3329/bjz.v39i2.10578 Bangladesh J. Zool. 39(2): 147-156, 2011


1993 ◽  
Vol 27 (1) ◽  
pp. 31-40 ◽  
Author(s):  
T. Wakatsuki ◽  
H. Esumi ◽  
S. Omura

Multi-Soil-Layering (MSL) method was applied to make appropriate, but high performance and N & P-removable, on-site domestic waste water treatment system. The MSL soil unit is composed from soil layer mixed with 10∼25% of metal iron and pelletized jute. The MSL units were piled in a brick pattern at 5cm vertical and 10cm horizontal distance, which were surrounded by layers of Zeolite. Air can be supplied through porous pipes installed at adequate depths of the MSL system. The systems were tested using model houses. The waste waters, which were pretreated by septic tank to the level of SS 29-75, BOD 42-116, COD 32-56, T-N 29-86, and T-P 6-11 mg−l−1 respectively, could be treated at the rate of 100-850 1·m−2·d−1 without significant clogging. The mean concentrations of treated waters were SS 15, BOD 8.7, COD 11, T-N 6.8, and T-P 0.86 mg·1−1 respectively. Zeolite layers and brick pattern prevent clogging. Metal iron and jute pellets were effective to remove Phosphate and Nitrate. Intensive aeration assists decomposition of BOD, COD, and SS as well as nitrification, but decreases denitrif ication and phosphate fixation. The degree of purification could be controlled by setting adequate aeration.


Sign in / Sign up

Export Citation Format

Share Document