Simultaneous nitrification and denitrification in biofilters with real time aeration control

2001 ◽  
Vol 43 (1) ◽  
pp. 269-276 ◽  
Author(s):  
N. Puznava ◽  
M. Payraudeau ◽  
D. Thornberg

The aim of this article is to present a new biological aerated filter (BAF) for nitrogen removal based on simultaneous nitrification and denitrification. Contrary to the systems which integrate both an aerated and a non-aerated zone to allow complete nitrogen removal in one compact or two different units (pre-denitrification and nitrification), this upflow BAF system is based on the principle of simultaneous nitrification and denitrification since the filter is completely aerated. The denitrification process is possible due to the diffusion effect which dominates biofilm processes. The real time aeration control allows us to maintain a low dissolved oxygen value (0.5 to 3 mg O2/l). In this case, the biofilm will not be fully (or less) penetrated with oxygen and denitrification will be carried out in a large part of the biofilm. Therefore, nitrification and denitrification is running simultaneously in different depths of the biofilm. By using 50% less air this BAF gave the same results (less than 20mg TN/l) on pilot plant as a classical nitrification and denitrification BAF (Toettrup et al., 1994). Less recirculation was necessary to achieve the same denitrification.

RSC Advances ◽  
2015 ◽  
Vol 5 (89) ◽  
pp. 72699-72708 ◽  
Author(s):  
Hooshyar Hossini ◽  
Abbas Rezaee ◽  
Bita Ayati ◽  
Amir Hossein Mahvi

In this study, the feasibility of ammonium and total nitrogen removal from aqueous solution using a simultaneous nitrification and denitrification process was studied in a membraneless bio-electrochemical system with a novel electrode.


RSC Advances ◽  
2018 ◽  
Vol 8 (48) ◽  
pp. 27417-27422 ◽  
Author(s):  
Peng Jin ◽  
Yinyan Chen ◽  
Zhanwang Zheng ◽  
Qizhen Du

A novel simultaneous nitrification and denitrification Klebsiella sp. exhibits high nitrogen removal efficiency under low-temperature and low C/N wastewater.


2006 ◽  
Vol 54 (8) ◽  
pp. 129-136 ◽  
Author(s):  
C. Lemoine ◽  
M. Payraudeau ◽  
J. Meinhold

Experience has shown that simultaneous nitrification/denitrification in a biological aerated filter is possible. However these systems react very sensitively to the aeration control strategies applied. Poorly adapted control strategies induce a strong decrease in treatment efficiency. A new control strategy for simultaneous N/DN is developed. The strategy proposed makes use of ammonia measurements and the inlet and outlet: a Feedback/Feedforward block. Passing by a calculation of the load to be eliminated, an estimation of the air flow velocity to be applied is carried out dynamically. A retroactive loop corrects this prediction in order to reach exactly the desired set point. This control approach has been implemented and tested at pilot plant scale for a period of 18 months. The pilot plant consists of two coupled BAF cells, reflecting closely industrial scale situations. Comparative studies reveal clearly the improved performance of the developed FF/FB control strategy compared to classical controllers. The benefits include 5% increase in nitrogen removal performance and a reduction of 15 to 20% in air requirement, offering a rapid return of investment costs.