Modeling of a reactive primary clarifier

2001 ◽  
Vol 43 (7) ◽  
pp. 73-81 ◽  
Author(s):  
K. Gernaey ◽  
P. A. Vanrolleghem ◽  
P. Lessard

Even though many models have been proposed for primary clarification, none is directly compatible with the ASM1. The objective of this paper is to present the development of a reactive primary clarifier model to be used in a wastewater treatment plant simulator (WEST). A model simulating COD behavior has been developed based on the Takacs model, and was tested with full-scale data. Particulate effluent COD was well described but problems occurred predicting the underflow suspended solids concentration. The model had to be upgraded with a residence time and a flocculation term to simulate the behavior of soluble COD. An ammonification term was added to the model, resulting in an improved model fit on effluent ammonium.

2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


1984 ◽  
Vol 16 (12) ◽  
pp. 649-660
Author(s):  
P Balmér ◽  
S Hallquist ◽  
M Hernebring

The Rya wastewater treatment plant in Gothenburg, Sweden serves 640 000 population equivalents. It is an extremely highly loaded activated sludge plant without presetting with a mean cell residence time of about 0.5 days. Ten years experience proves that the plant is capable of removing about 70% of the BOD load. The effluent BOD is mainly caused by non settleable suspended solids due to the partly dispersed growth of the activated sludge. The low mean cell residence time and the high suspended solids concentration in the aeration basin influent gives an activated sludge with low viability and in mass balance studies it was determined that only 12% of the influent COD and about 40% of the BOD was oxidized by the activated sludge. The activated sludge has consistently had a very low sludge volume index and the settling basins could thus be very highly loaded. The surplus activated sludge could be thickened to solids concentrations over 6%. After dewatering the sludge was either lime treated or co-composted with bark. The plant is manned only eight hours five days a week. During unmanned time there are standby personnel. Data is presented on man power, energy and chemical use, and on costs.


2017 ◽  
Vol 77 (3) ◽  
pp. 739-747 ◽  
Author(s):  
J. D. Kenny ◽  
B. D. Webber ◽  
E. W. Howe ◽  
R. B. Holden

Abstract Dieldrin and DDx removal through wastewater treatment, ozonation, and microfiltration was assessed for a water reuse project for groundwater replenishment in Monterey, California, USA. Full-scale sampling was conducted at the wastewater treatment plant, and physical wastewater treatment processes, ozonation, and microfiltration were tested at the bench scale. Removals observed through wastewater treatment, ozonation, and microfiltration were 84%, 44% to 63%, and 97% to 98%, respectively, for dieldrin, and 93%, 36% to 48%, and 92% to 94% for DDx. These were sufficient to meet California Ocean Plan water quality objectives after wastewater treatment alone. Levels in the secondary effluent, ahead of ozonation, microfiltration, reverse osmosis and advanced oxidation in the advanced water purification facility, met drinking water standards. Removal of dieldrin and DDx through wastewater treatment occurred by physical treatment processes; removal through the full-scale wastewater treatment plant, which included biological and physical treatment processes, matched removal through the physical bench-scale wastewater treatment processes. Dieldrin and DDx removal correlated with removal of volatile suspended solids, suggesting that volatile suspended solids could be used as an indicator for pesticide removal through wastewater treatment. Dieldrin and DDx concentrations were highest in the solids contact process, where biomass is accumulated for carbon removal.


1995 ◽  
Vol 31 (12) ◽  
pp. 171-183 ◽  
Author(s):  
M. M. Saqqar ◽  
M. B. Pescod

The performance of the primary anaerobic pond at the Alsamra Wastewater Treatment Plant in Jordan was monitored over 48 months. Overall averages for the removal efficiencies of BOD5, COD and suspended solids were 53%, 53% and 74%, respectively. An improvement in removal efficiency with increase in pond water temperature was demonstrated. A model, which takes into account the variability of raw wastewater at different locations, has been developed to describe the performance of a primary anaerobic pond in terms of a settleability ratio for the raw wastewater. The model has been verified by illustrating the high correlation between actual and predicted pond performance.


2000 ◽  
Vol 41 (1) ◽  
pp. 177-185 ◽  
Author(s):  
G. Andreottola ◽  
P. Foladori ◽  
M. Ragazzi

The aim of this study was to evaluate the performance of a full-scale upgrading of an existing RBC wastewater treatment plant with a MBBR (Moving Bed Biofilm Reactor) system, installed in a tank previously used for sludge aerobic digestion. The full-scale plant is located in a mountain resort in the North-East of Italy. Due to the fact that the people varied during the year's seasons (2000 resident people and 2000 tourists) the RBC system was insufficient to meet the effluent standards. The MBBR applied system consists of the FLOCOR-RMP®plastic media with a specific surface area of about 160 m2/m3 (internal surface only). Nitrogen and carbon removal from wastewater was investigated over a 1-year period, with two different plant lay-outs: one-stage (only MBBR) and two stage system (MBBR and rotating biological contactors in series). The systems have been operated at low temperature (5–15°C). 50% of the MBBR volume (V=79 m3) was filled. The organic and ammonium loads were in the average 7.9 gCOD m−2 d−1 and 0.9 g NH4−N m−2 d−1. Typical carbon and nitrogen removals in MBBR at temperature lower than 8°C were respectively 73% and 72%.


2018 ◽  
Vol 85 (5) ◽  
Author(s):  
Veronica R. Brand ◽  
Laurel D. Crosby ◽  
Craig S. Criddle

ABSTRACTMultiple clades within a microbial taxon often coexist within natural and engineered environments. Because closely related clades have similar metabolic potential, it is unclear how diversity is sustained and what factors drive niche differentiation. In this study, we retrieved three near-complete Competibacter lineage genomes from activated sludge metagenomes at a full-scale pure oxygen activated sludge wastewater treatment plant. The three genomes represent unique taxa within theCompetibacteraceae. A comparison of the genomes revealed differences in capacity for exopolysaccharide (EPS) biosynthesis, glucose fermentation to lactate, and motility. Using quantitative PCR (qPCR), we monitored these clades over a 2-year period. The clade possessing genes for motility and lacking genes for EPS biosynthesis (CPB_P15) was dominant during periods of suspended solids in the effluent. Further analysis of operational parameters indicate that the dominance of the CPB_P15 clade is associated with low-return activated sludge recycle rates and low wasting rates, conditions that maintain relatively high levels of biomass within the system.IMPORTANCEMembers of the Competibacter lineage are relevant in biotechnology as glycogen-accumulating organisms (GAOs). Here, we document the presence of threeCompetibacteraceaeclades in a full-scale activated sludge wastewater treatment plant and their linkage to specific operational conditions. We find evidence for niche differentiation among the three clades with temporal variability in clade dominance that correlates with operational changes at the treatment plant. Specifically, we observe episodic dominance of a likely motile clade during periods of elevated effluent turbidity, as well as episodic dominance of closely related nonmotile clades that likely enhance floc formation during periods of low effluent turbidity.


Sign in / Sign up

Export Citation Format

Share Document