Ozonation followed by coagulation/flocculation and flotation as post-treatment of the effluent from an anaerobic baffled reactor treating domestic sewage

2001 ◽  
Vol 43 (8) ◽  
pp. 99-106 ◽  
Author(s):  
M. M. Marchioretto ◽  
M. A. Reali

This paper reports on the use of ozonation and dissolved air flotation as a post-treatment of the effluent from an anaerobic baffled reactor treating domestic sewage. After preliminary essays, the present experiment was performed fixing coagulant doses and, to all of them, some ozone doses were investigated. Later, the pH value and the ozone dose which provided the best removal efficiencies of all the parameters involved were tested, changing the coagulant dose and varying, for each of them, two ozone doses: the zero one and the optimum. Considering the best conditions of coagulation/flotation (ferric chloride dose of 65 mg.L−1: and pH around 5.5), the ozone dose application of 6 mg.L−1 led to a significant level in the removal efficiency of COD (80.4%), BOD (79.0%), total phosphate (93.4%), apparent color (91.9%) and turbidity (97.0%), demonstrating that the system seems to be efficient and capable of promoting a high degree of sewage post-treatment, reducing the coagulant dose until 30%, with a consequent reduction in the sludge generation.

1999 ◽  
Vol 40 (8) ◽  
pp. 137-143 ◽  
Author(s):  
R. G. Penetra ◽  
M. A. P. Reali ◽  
E. Foresti ◽  
J. R. Campos

This paper presents the results of a study performed with a lab-scale dissolved-air flotation (LSDAF) unit fed with previously coagulated effluent from a pilot scale up-flow anerobic sludge blanket (UASB) reactor treating domestic sewage. Physical operational conditions for coagulation (rapid mix) and flocculation/flotation were maintained constant. Chemical (FeCl3) dosages ranged from 30 to 110 mg.l−1. The effect of pH was also verified in the range of 5.1 to 7.6 for each dosage. Best results were achieved for 65 mg.l−1 of FeCl3 and pH values between 5.3 and 6.1. For these conditions, the removal efficiencies obtained in the LSDAF unit were: between 87% and 91% for chemical oxygen demand (COD), between 95% and 96% for total phosphate (TP), 94% for total suspended solids (TSS), between 96% and 97% for turbidity (TU), between 90% and 93% for apparent color (AC) and more than 96% for sulfide (S). For the UASB-DAF system, global efficiencies would be around 98% for COD, 98% for TP, 98.4% for TSS, 99.3% for TU and 98% for AC. The stripped gases treatment is desirable.


1986 ◽  
Vol 18 (9) ◽  
pp. 105-114 ◽  
Author(s):  
D. Misković ◽  
B. Dalmacija ◽  
Ž Živanov ◽  
E. Karlović ◽  
Z. Hain ◽  
...  

The objective of the present investigation was a high level of purification of the wastewater from an oil refinery achieved by using some improved methods yielding an effluent suitable for recycling into the process. All the investigations were carried out on a continuous laboratory pilot system consisting of the following units: dissolved air flotation (DAF), sedimentation, double-stage microbiological reactor, and adsorption columns filled with granular biologically activated carbon (GBAC). A high degree of COD reduction close to 100% (precisely, 99.95 %), as well as removal of nitrogen compounds of 72% was achieved during a relatively short retention time within the range of 15-16.5 hrs. The DAF technique combined with gravitational separation was used to achieve the recovery of free oil matter up to 98%, without any preliminary conditioning. After the sedimentation of coagulated and flocculated dispersed oils, the microbiological oxidation of dissolved matter was accomplished by using two kinds of activated sludge for easy and hard degradable organics. Using the continuously bioregenerating GBAC, an effluent having a lowered COD value to about 9 was obtained. At the same time, the denitrification process took place. According to the obtained results the treated oil refinery wastewater can be recycled into the process, or discharged into a water recipient of a low self-purifying capacity.


2003 ◽  
Vol 48 (6) ◽  
pp. 285-293
Author(s):  
R.G. Penetra ◽  
M.A.P. Reali ◽  
J.R. Campos

This paper presents the results of a study performed with an experimental domestic sewage treatment plant (240 m3.d-1 flow) consisting of expanded bed anaerobic reactor (EBAR) followed by dissolved air flotation (DAF) unit. For the flotation step, the anaerobic reactor effluent was previously coagulated with 50 mgFeCl3.l-1 and flocculated under different conditions (mean velocity gradient, Gf, and flocculation time, Tf). The Gf values were from 60 to 100 s-1 associated with 13 and 20 min Tf values. During the tests, the following operational conditions of the flotation unit were maintained: chemical addition (50 mgFeCl3.l-1), 18% recirculation rate associated with a pressure of 450 ± 10 kPa in the saturation chamber and overflow rate of 180 m3.mÐ2.d-1. Temperature ranged from 23.8¡C to 30.01/4C. Best results were achieved for Gf = 80 s-1 and Tf = 20 min. For these conditions, the DAF unit removal efficiencies were: 94.4% for chemical oxygen demand (with 53 mg.l-1 COD residual), 87% for phosphorus (with 0.80 mgP.l-1 residual), 96.7% for total suspended solids (with 9 mg.l-1 TSS residual) and 96.4% for turbidity (with 12.9 NTU residual), when the anaerobic reactor effluents have worst quality during the whole day.


2018 ◽  
Author(s):  
◽  
Emmanuel Kweinor Tetteh

Industrial mineral oil wastewater from oil refineries and petrochemical processing poses a major environmental concern. Effluents from these processes is usually poor as it is heavily polluted, thus have high chemical oxygen demand (COD), soap oil and grease (SOG), turbidity, total suspended solids (TSS) amongst others. This wastewater, if discharge without treatment, causes severe pollution, oxygen depletion, and imbalanced ecosystem and human health risks. The main aim of this research was to modify, optimise and evaluate the performance of a continuous process using dissolved air flotation (DAF) pilot to treat wastewater from a local South African oil refinery wastewater treatment plant (WWTP) with the benefit of recovery of the oil from the wastewater. The study evaluated the feasibility of using different acids and coagulants. One factor at time (OFAT) approach was used on the DAF jar tester to identify the most important variables that affects the DAF treatability performance. The factors considered were; pH, flotation time, coagulant dosage, air to water ratio and air saturated pressure. The ranges considered for the factors were pH (4−6), flotation time (5−15 minutes), coagulant dosage (10−50 mg/L), air to water ratio (5–15%) and air saturated pressure (300–500 kPa). The key process operating parameters obtained from the OFAT were optimised using the Box Behnken design (BBD) adapted from response surface methodology (RSM). The BBD used had three levels, three factors and five centre points. This was employed to establish the relationship that existed between the water quality (contaminants) and the key interacting factors of the DAF jar tester, thus employing the most applicable combination of the factors on a continuous DAF pilot plant. The study was configured into two; Acid – Coagulation-DAF (pre-treatment) and Acid –DAF – Coagulation (post treatment). Three acids were investigated for their efficiency in the pre- treatment step, while four cationic inorganic coagulants and three polymeric organic coagulants were used both for the pre and post treatments. The OFAT experiments resulted in more than 75% removal efficiency of COD, SOG, TSS and turbidity. The removal efficiency was obtained at the following optimum values of pH 5, flotation time of 15 minutes at a coagulant dosage of 50 mg/L and an air to water ratio of 10% and finally, air saturated pressure was 350 kPa. On the other hand, BBD results showed 85% treatability performance at a lower coagulant dosage (30–45 mg/L), moderate air saturator pressure (300–425 kPa), and air-water ratio (8–12%) on the batch scale. While on the continuous process, the optimum coagulant dosage was around 100–180 mg/L. From the BBD results, the interacted factors for consideration were the air saturated pressure and coagulant dosage. These factors enhanced process control. The validation of all the response quadratic models were in good standing with the analysis of variance (ANOVA). The experimental results and the predicted models results agreed at 95% confidence level, finally, the models were significant and verified. Comparative studies of the pre and post treatment showed that 1 M H3PO4 was the most effective, economical and environmentally friendly acid to be used for both processes. Two cationic inorganic (alum and ferric chloride) and two polymeric organic (Z553D-PAC and Zetag32-FS/A50) coagulants were found to be effective with remarkable performance to destabilise and neutralise the oil droplets to coalesce larger flocs to enhance the oil-water separation. Far and above, the cationic inorganic coagulants were more cost effective than the polymeric organic coagulants, even though, the inorganic coagulants were cheaper they had higher conductivity (salts), thus raising environmental concerns. In conclusion, the pre-treatment of the DAF process yielded more recovery of water and oil, and hence this step was economically viable. The RSM demonstrated to be more effective and reliable in finding the optimal conditions of the DAF process than the OFAT method. Thus, the RSM offered a better option than the OFAT, because it included both the interactional and individual factors.


Processes ◽  
2020 ◽  
Vol 8 (4) ◽  
pp. 383 ◽  
Author(s):  
Emmanuel Kweinor Tetteh ◽  
Sudesh Rathilal

The effects of coagulation-dissolved air flotation (DAF) process configuration was studied on oil refinery wastewater. The configuration was done in two ways: acid-coagulation-DAF (pre-treatment) and acid-DAF-coagulation (post-treatment). Two different cationic and polymeric organic coagulants were employed in this study to compare their treatability performance with the two aforementioned configurations. All the coagulants applied before the DAF were found to be effective, with over 85% more contaminant removal efficiency than their post-treatment. Alum, being the most cost-effective coagulant, was then employed with response surface methodology (RSM) to obtain the optimum conditions. These include a coagulant dosage of 100 mg/L, air saturator pressure of 375 kPa and air–water ratio of 10% vol/vol corresponding to a desirability of 92% for the removal of oily pollutants from a local South Africa oil refinery’s wastewater. With the response quadratic models that were developed, the optimum conditions were tested experimentally, which were consistent with the models predicted results at a 95% confidence level.


2014 ◽  
Vol 802 ◽  
pp. 268-273
Author(s):  
M.A. Santos ◽  
R.C. Santana ◽  
F. Capponi ◽  
M.C. Nery ◽  
C.H. Ataíde ◽  
...  

The use of recycled water in the apatite flotation may result in losses to the process performance due to the presence of ions, residual reagents, finely particulate material, etc. The dissolved air flotation (DAF) has been shown an efficient technique in the wastewater treatment in the removal of these pollutants. The use of anionic collector in DAF process is based on the reaction that occurs between the soybean oil soap (apatite collector) with the calcium present in the apatite lattice making its surface hydrophobic. Therefore, the collector can be an auxiliary in the water softening besides improving the hydrophobicity of the particles to be collected. Thus, this study was aimed at evaluating the effect of an anionic collector used as an auxiliary in the dissolved air flotation process. A central composite design (CCD) was proposed to evaluate the concentration of collector and the effect of pH value on the removal efficiency of calcium, magnesium, fluoride, phosphorous and turbidity present in a wastewater from a fertilizer industry. The results showed a good removal of the contaminants which guaranteed a better quality of water to the process of phosphate rock concentration.


1995 ◽  
Vol 31 (3-4) ◽  
pp. 25-35 ◽  
Author(s):  
E. M. Rykaart ◽  
J. Haarhoff

A simple two-phase conceptual model is postulated to explain the initial growth of microbubbles after pressure release in dissolved air flotation. During the first phase bubbles merely expand from existing nucleation centres as air precipitates from solution, without bubble coalescence. This phase ends when all excess air is transferred to the gas phase. During the second phase, the total air volume remains the same, but bubbles continue to grow due to bubble coalescence. This model is used to explain the results from experiments where three different nozzle variations were tested, namely a nozzle with an impinging surface immediately outside the nozzle orifice, a nozzle with a bend in the nozzle channel, and a nozzle with a tapering outlet immediately outside the nozzle orifice. From these experiments, it is inferred that the first phase of bubble growth is completed at approximately 1.7 ms after the start of pressure release.


1998 ◽  
Vol 37 (2) ◽  
pp. 35-42 ◽  
Author(s):  
M. J. Bauer ◽  
R. Bayley ◽  
M. J. Chipps ◽  
A. Eades ◽  
R. J. Scriven ◽  
...  

Thames Water treats approximately 2800Ml/d of water originating mainly from the lowland rivers Thames and Lee for supply to over 7.3million customers, principally in the cities of London and Oxford. This paper reviews aspects of Thames Water's research, design and operating experiences of treating algal rich reservoir stored lowland water. Areas covered include experiences of optimising reservoir management, uprating and upgrading of rapid gravity filtration (RGF), standard co-current dissolved air flotation (DAF) and counter-current dissolved air flotation/filtration (COCO-DAFF®) to counter operational problems caused by seasonal blooms of filter blocking algae such as Melosira spp., Aphanizomenon spp. and Anabaena spp. A major programme of uprating and modernisation (inclusion of Advanced Water Treatment: GAC and ozone) of the major works is in progress which, together with the Thames Tunnel Ring Main, will meet London's water supply needs into the 21st Century.