Importance of the order in enhancing EfOM removal by combination of BAC and MIEX®

2011 ◽  
Vol 64 (11) ◽  
pp. 2325-2332 ◽  
Author(s):  
A. Aryal ◽  
A. Sathasivan

Biological activated carbon (BAC) is operationally a simple treatment which can be employed to remove effluent organic matter (EfOM) from secondary wastewater effluent (SWWE). Unfortunately, BAC removes only a limited amount of dissolved organic carbon (DOC). Thus, maximizing DOC removal from SWWE using BAC is a major concern in wastewater reuse. This study has investigated a hybrid system of BAC and Magnetic Ion Exchange Resin (MIEX®) for the enhanced removal of DOC. Performance of both BAC prior to MIEX® (BAC/MIEX®) and reverse (MIEX®/BAC) combination was evaluated in terms of DOC removal. The BAC/MIEX® showed much better DOC removal. This is because microbial activity in the BAC bed converted MIEX® non-amenable DOC to MIEX® amenable DOC. As a result, BAC/MIEX® combination synergised DOC removal. In addition, BAC was also found to be highly effective in reducing MIEX® dose for a given DOC removal from SWWE.

2011 ◽  
Vol 11 (1) ◽  
pp. 15-22 ◽  
Author(s):  
C. Liu ◽  
W. Chen ◽  
V. M. Robert ◽  
Z. G. Han

Natural organic matter (NOM) fouling continues to be the major barrier to efficient application of ultrafiltration (UF) in drinking water treatment. Algogenic organic matter (AOM), the main contributor to total NOM levels in raw waters characterised by elevated algae levels, is currently the subject of much investigation. In this study, the effect of AOM on fouling of ultrafiltration and the effectiveness of magnetic ion exchange resin (MIEX®) pre-treatment for AOM removal and membrane fouling control was evaluated. The results showed that, the main species of algae in raw water were Chlorella vulgaris, which accounted for 80% of total algae. AOM was predominantly hydrophilic (50% or more) with a low SUVA (1.7 Lm−1 mg−1). Coagulation alone could not remove AOM effectively (less than 20%), however, when combined with magnetic ion exchange resin pre-treatment, more than 60% of AOM was be removed; pre-treatment followed by coagulation was observed to be very effective in controlling membrane fouling by AOM. The application of magnetic ion exchange resin technology at a bed volume treatment rate (BVTR) of 800 was observed to effectively eliminate fouling of UF membrane. Careful analyses of the molecular weight (MW) distribution of AOM and UV absorbance of treated water revealed that the effectiveness in membrane fouling control was the result of the changes in AOM molecular characteristics in treated water, namely a change in MW due to the preferential removal of high molecular proteins by coagulation and magnetic ion exchange resin pre-treatment. The results demonstrate that magnetic ion exchange resin followed by coagulation might be a new membrane pre-treatment option for UF membrane fouling control.


2007 ◽  
Vol 67 (12) ◽  
pp. 1495-1504 ◽  
Author(s):  
Mehmet Kitis ◽  
B. İlker Harman ◽  
Nevzat O. Yigit ◽  
Mehmet Beyhan ◽  
Hung Nguyen ◽  
...  

2008 ◽  
Vol 42 (8-9) ◽  
pp. 1977-1988 ◽  
Author(s):  
Max R.D. Mergen ◽  
Bruce Jefferson ◽  
Simon A. Parsons ◽  
Peter Jarvis