Quantitative detection of human enteric adenoviruses in river water by microfluidic digital polymerase chain reaction

2014 ◽  
Vol 70 (3) ◽  
pp. 555-560 ◽  
Author(s):  
Naohiro Kishida ◽  
Naohiro Noda ◽  
Eiji Haramoto ◽  
Mamoru Kawaharasaki ◽  
Michihiro Akiba ◽  
...  

We describe an assay for simple and accurate quantification of human enteric adenoviruses (EAdVs) in water samples using a recently developed quantification method named microfluidic digital polymerase chain reaction (dPCR). The assay is based on automatic distribution of reaction mixture into a large number of nanolitre-volume reaction chambers and absolute copy number quantification from the number of chambers containing amplification products on the basis of Poisson statistics. This assay allows absolute quantification of target genes without the use of standard DNA. Concentrations of EAdVs in Japanese river water samples were successfully quantified by the developed dPCR assay. The EAdVs were detected in seven of the 10 samples (1 L each), and the concentration ranged from 420 to 2,700 copies/L. The quantified values closely resemble those by most probable number (MPN)-PCR and real-time PCR when standard DNA was validated by dPCR whereas they varied substantially when the standard was not validated. Accuracy and sensitivity of the dPCR was higher than those of real-time PCR and MPN-PCR. To our knowledge, this is the first study that has successfully quantified enteric viruses in river water using dPCR. This method will contribute to better understanding of existence of viruses in water.

2010 ◽  
Vol 134 (3) ◽  
pp. 444-448 ◽  
Author(s):  
Zhengming Gu ◽  
Jianmin Pan ◽  
Matthew J. Bankowski ◽  
Randall T. Hayden

Abstract Context.—BK virus infections among immunocompromised patients are associated with disease of the kidney or urinary bladder. High viral loads, determined by quantitative polymerase chain reaction (PCR), have been correlated with clinical disease. Objective.—To develop and evaluate a novel method for real-time PCR detection and quantification of BK virus using labeled primers. Design.—Patient specimens (n = 54) included 17 plasma, 12 whole blood, and 25 urine samples. DNA was extracted using the MagNA Pure LC Total Nucleic Acid Isolation Kit (Roche Applied Science, Indianapolis, Indiana); sample eluate was PCR-amplified using the labeled primer PCR method. Results were compared with those of a user-developed quantitative real-time PCR method (fluorescence resonance energy transfer probe hybridization). Results.—Labeled primer PCR detected less than 10 copies per reaction and showed quantitative linearity from 101 to 107 copies per reaction. Analytical specificity of labeled primer PCR was 100%. With clinical samples, labeled primer PCR demonstrated a trend toward improved sensitivity compared with the reference method. Quantitative assay comparison showed an R2 value of 0.96 between the 2 assays. Conclusions.—Real-time PCR using labeled primers is highly sensitive and specific for the quantitative detection of BK virus from a variety of clinical specimens. These data demonstrate the applicability of labeled primer PCR for quantitative viral detection and offer a simplified method that removes the need for separate oligonucleotide probes.


2006 ◽  
Vol 89 (1) ◽  
pp. 240-244 ◽  
Author(s):  
Zhi-Qin Yue ◽  
Hong Liu ◽  
Wei-Ji Wang ◽  
Zhi-Wen Lei ◽  
Cheng-Zhu Liang ◽  
...  

Abstract An assay was developed for the detection of infectious hypodermal and hematopoietic necrosis virus (IHHNV) based on real-time quantitative polymerase chain reaction (PCR). A pair of primers and a TaqMan probe were designed that are specific for the recognition of a conservative region in the IHHNV genome. The IHHNV real-time PCR assay had a detection limit of 9 DNA copies,with a dynamic range of detection between 9 106 and 9 DNA copies. The primer pairs and probe were specific to IHHNV and did not cross-reactwith shrimp genomic DNAor other shrimp viruses such as White Spot Syndrome Virus (WSSV), Monodon Baculovirus (MBV), and hepatopancreatic parvovirus (HPV). This assay has a broad application for basic and clinical investigations. For clinical samples, the real-time PCR assay detected all the positive samples screened by conventional PCR, which indicated the sensitivity of the real-time assay. The IHHNV real-time PCR assay with high sensitivity, specificity, wide range of detection ability, and simplicity is particularly useful for screening large numbers of specimens and measuring viral loads to monitor the broodstock.


Author(s):  
Ika Yasma Yanti ◽  
Dalima Ari Wahono Astrawinata

Toxigenic Clostridium difficile infection, causing a Pseudo Membrane Colitis (PMC) and Clostridium Difficile Associated Diarrhea(CDAD) has increased sharply. The largest risk factor is the use of antibiotics. The purpose of this study was to know how to determinethe prevalence and characteristics of subjects with Toxigenic Clostridium difficile and to assess the ability of the toxin rapid test comparedto real-time PCR. Ninety adult subjects with antibiotic therapy more than two (2) weeks were enrolled in this study. The results of toxinrapid test and real-time PCR were presented in a 2x2 table, statistical test used was Chi square. The prevalence of Toxigenic Clostridiumdifficile based on the toxin rapid test and by real-time PCR was 27.3% and 37.5%, respectively. There were significant differences betweenstool consistency and number of antibiotics used with the detection of Toxigenic Clostridium difficile. There was a relationship betweenthe duration of antibiotic therapy with the detection of Toxigenic Clostridium difficile using real-time PCR (p=0.010, RR=2.116). Thesensitivity, specificity, PPV, NPV, PLR and NLR rapid test against real-time PCR were 69.7%; 98.2%; 95.8%; 84.4%; 39.2 and 0.31,respectively. This study concluded that the prevalence of Clostridium difficile in RSCM was higher compared to that in Malaysia, Thailandand India; the subjects with antibiotic therapy for more than four (4) weeks had a double risk to have Toxigenic Clostridium difficilethan subjects with antibiotic therapy for less than that time (4 weeks). Thus, in this study, toxin rapid test could be used as a tool todetect Toxigenic Clostridium difficile.


Sign in / Sign up

Export Citation Format

Share Document