scholarly journals Two-stage anaerobic process benefits removal for azo dye Orange II with starch as primary co-substrate

Author(s):  
Jingang Huang ◽  
Binfang Shi ◽  
Zhenjiang Yin ◽  
Kangyin Guo ◽  
Chen Fu ◽  
...  

Abstract Two-stage anaerobic system (S1: R1 (acidogenic phase) + R2 (methanogenic phase)) and the one-stage control (S0) were established to investigate the effect of phase separation on the removal of an azo dye orange II, i.e., Acid Orange 7 (AO7), with starch as the primary co-substrate. Although final AO7 removal from two systems showed no statistical differences, the first-order rate constants for AO7 removal (kAO7­) and sulfanilic acid (SA) formation (kSA) were higher in S1. Kinetic analysis showed that kAO7­ and kSA in S1 were 2.7-fold and 1.7-fold of those in S0, respectively, indicating the benefit of phase separation to the AO7 reduction. However, this benefit only appeared in the period with influent AO7 concentrations higher than 2.14 mM. Otherwise, this advantage would be hidden due to the longer HRT (5 d) and sufficient electron donor (1.0 g starch L−1). Within S1, R1 only contributed about 10% of the entire AO7 removal, and kAO7­ in R1 (0.172 h−1) was much lower than in R2 (0.503 h−1). The methanogenic phase rather than acidogenic phase was the main contribution to AO7 removal, because the influent of R2 had more available electron donors and suitable pH condition (pH 6.5–7.0) for the bio-reduction process.

1967 ◽  
Vol 18 (01/02) ◽  
pp. 198-210 ◽  
Author(s):  
Ronald S Reno ◽  
Walter H Seegers

SummaryA two-stage assay procedure was developed for the determination of the autoprothrombin C titre which can be developed from prothrombin or autoprothrombin III containing solutions. The proenzyme is activated by Russell’s viper venom and the autoprothrombin C activity that appears is measured by its ability to shorten the partial thromboplastin time of bovine plasma.Using the assay, the autoprothrombin C titre was determined in the plasma of several species, as well as the percentage of it remaining in the serum from blood clotted in glass test tubes. Much autoprothrombin III remains in human serum. With sufficient thromboplastin it was completely utilized. Plasma from selected patients with coagulation disorders was assayed and only Stuart plasma was abnormal. In so-called factor VII, IX, and P.T.A. deficiency the autoprothrombin C titre and thrombin titre that could be developed was normal. In one case (prethrombin irregularity) practically no thrombin titre developed but the amount of autoprothrombin C which generated was in the normal range.Dogs were treated with Dicumarol and the autoprothrombin C titre that could be developed from their plasmas decreased until only traces could be detected. This coincided with a lowering of the thrombin titre that could be developed and a prolongation of the one-stage prothrombin time. While the Dicumarol was acting, the dogs were given an infusion of purified bovine prothrombin and the levels of autoprothrombin C, thrombin and one-stage prothrombin time were followed for several hours. The tests became normal immediately after the infusion and then went back to preinfusion levels over a period of 24 hrs.In other dogs the effect of Dicumarol was reversed by giving vitamin K1 intravenously. The effect of the vitamin was noticed as early as 20 min after administration.In response to vitamin K the most pronounced increase was with that portion of the prothrombin molecule which yields thrombin. The proportion of that protein with respect to the precursor of autoprothrombin C increased during the first hour and then started to go down and after 3 hrs was equal to the proportion normally found in plasma.


1983 ◽  
Vol 50 (03) ◽  
pp. 697-702 ◽  
Author(s):  
T W Barrowcliffe ◽  
A D Curtis ◽  
D P Thomas

SummaryAn international collaborative study was carried out to establish a replacement for the current (2nd) international standard for Factor VIII: C, concentrate. Twenty-six laboratories took part, of which 17 performed one-stage assays, three performed two-stage assays and six used both methods. The proposed new standard, an intermediate purity concentrate, was assayed against the current standard, against a high-purity concentrate and against an International Reference Plasma, coded 80/511, previously calibrated against fresh normal plasma.Assays of the proposed new standard against the current standard gave a mean potency of 3.89 iu/ampoule, with good agreement between laboratories and between one-stage and two- stage assays. There was also no difference between assay methods in the comparison of high-purity and intermediate purity concentrates. In the comparison of the proposed standard with the plasma reference preparation, the overall mean potency was 4.03 iu/ampoule, but there were substantial differences between laboratories, and the two-stage method gave significantly higher results than the one stage method. Of the technical variables in the one-stage method, only the activation time with one reagent appeared to have any influence on the results of this comparison of concentrate against plasma.Accelerated degradation studies showed that the proposed standard is very stable. With the agreement of the participants, the material, in ampoules coded 80/556, has been established by the World Health Organization as the 3rd International Standard for Factor VIII :C, Concentrate, with an assigned potency of 3.9 iu/ampoule.


2021 ◽  
Vol 11 (5) ◽  
pp. 2239
Author(s):  
Hailin Zhao ◽  
Hua Su ◽  
Guoding Chen ◽  
Yanchao Zhang

To solve the high leakage and high wear problems faced by sealing devices in aeroengines under the condition of high axial pressure difference, the two-stage finger seal is proposed in this paper. The finite element method and computational fluid dynamics (FEM/CFD) coupling iterative algorithm of the two-stage finger seal is developed and validated. Then the performance advantages of two-stage finger seal compared to the one-stage finger seal are studied, as well as the leakage and the inter-stage pressure drop characteristics of two-stage finger seal are investigated. Finally, the measure to improve the inter-stage imbalance of pressure drop of two-stage finger seal is proposed. The results show that the two-stage finger seal has lower leakage and lower contact pressure than the one-stage finger seal at high axial pressure difference, but there exists an inter-stage imbalance of pressure drop. Increasing the axial pressure difference and the root mean square (RMS) roughness of finger element can aggravate the imbalance of pressure drop, while the radial displacement excitation of rotor has little influence on it. The results also indicate that the inter-stage imbalance of pressure drop of the two-stage finger seal can be improved by increasing the number of finger elements of the 1st finger seal and decreasing the number of finger elements of the 2nd finger seal.


Author(s):  
Anil Kumar ◽  
Virendra Kumar ◽  
PMV Subbarao ◽  
Surendra K Yadav ◽  
Gaurav Singhal

The two-stage ejector has been suggested to replace the single-stage ejector geometrical configuration better to utilize the discharge flow’s redundant momentum to induce secondary flow. In this study, the one-dimensional gas dynamic constant rate of momentum change theory has been utilized to model a two-stage ejector along with a single-stage ejector. The proposed theory has been utilized in the computation of geometry and flow parameters of both the ejectors. The commercial computational fluid dynamics tool ANSYS-Fluent 14.0 has been utilized to predict performance and visualize the flow. The performance in terms of entrainment ratio has been compared under on- design and off-design conditions. The result shows that the two-stage ejector configuration has improved (≈57%) entrainment capacity than the single-stage ejector under the on-design condition.


Sign in / Sign up

Export Citation Format

Share Document