scholarly journals Heat Load Characteristics and New Type Design by Using 1 Coil Model Superconducting Magnet.

Author(s):  
Yoshihiro JIZO ◽  
Hidenari AKAGI ◽  
Takashi YAMAGUCHI ◽  
Motoaki TERAI ◽  
Masatoshi SHINOBU
Author(s):  
Hideo TSUCHISHIMA ◽  
Motoaki TERAI ◽  
Hakaru YOSHIDA ◽  
Hiroyuki WATANABE ◽  
Mutsuhiko YAMAJI ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1792
Author(s):  
Bingbing Dong ◽  
Yu Gu ◽  
Changsheng Gao ◽  
Zhu Zhang ◽  
Tao Wen ◽  
...  

In recent years, the new type design of current transformer with bushing structure has been widely used in the distribution network system due to its advantages of miniaturization, high mechanical strength, maintenance-free, safety and environmental protection. The internal temperature field distribution is an important characteristic parameter to characterize the thermal insulation and aging performance of the transformer, and the internal temperature field distribution is mainly derived from the joule heat generated by the primary side guide rod after flowing through the current. Since the electric environment is a transient field and the thermal environment changes slowly with time as a steady field under the actual conditions, it is more complex and necessary to study the electrothermal coupling field of current transformer (CT). In this paper, a 3D simulation model of a new type design of current transformer for distribution network based on electric-thermal coupling is established by using finite element method (FEM) software. Considering that the actual thermal conduction process of CT is mainly by conduction, convection and radiation, three different kinds of boundary conditions such as solid heat transfer boundary condition, heat convection boundary condition and surface radiation boundary condition are applied to the CT. Through the model created above, the temperature rise process and the distribution characteristics of temperature gradient of the inner conductor under different current, different ambient temperatures and different core diameters conditions are studied. Meanwhile, the hottest temperature and the maximum temperature gradient difference are calculated. According to this, the position of weak insulation of the transformer is determined. The research results can provide a reference for the factory production of new type design of current transformer.


2019 ◽  
Vol 79 (1) ◽  
pp. 84
Author(s):  
Yu ming Wang ◽  
Qi dong Wang ◽  
Li qing Chen ◽  
Tian yi Gu

2004 ◽  
Vol 14 (2) ◽  
pp. 1704-1707 ◽  
Author(s):  
R. Pengo ◽  
N. Dolgetta ◽  
S. Junker ◽  
G. Passardi ◽  
H. tenKate

Cryogenics ◽  
1997 ◽  
Vol 37 (9) ◽  
pp. 479-486 ◽  
Author(s):  
H. Tsuchishima ◽  
M. Terai ◽  
H. Yoshida ◽  
H. Watanabe ◽  
M. Yamaji ◽  
...  

2006 ◽  
Vol 5 (2) ◽  
pp. 421-428 ◽  
Author(s):  
Kyung-Soon Park ◽  
Hisaya Nagai ◽  
Takeshi Iwata

Sign in / Sign up

Export Citation Format

Share Document