scholarly journals Method Development and Validation of A Novel Anti-Depressant Bupropion by RP-HPLC

2020 ◽  
Vol 8 (3) ◽  
pp. 211-224
Author(s):  
Anil Kumar ◽  
Dilip Agarwal ◽  
Mukesh Bansal

A speedy, simple and precise RP-HPLC process was developed for the estimation of novel antidepressant drug bupropion with Waters X – Bridge C-18 5µm, 4.6 X 150 mm columnusing mobile phase Acetonitrile: Ammonium bicarbonate (5mM) pH-9 adjusted with 1% Ammonium hydroxide (50:50, %v/v).The flow rate was 1 ml/min and quantification was done by PDA detector at wavelength254nm.The Bupropion eluted from the column in 5.194 min. The validation was carried out in the light of ICH guidelines with respect to parameters linearity, specificity, accuracy, limit of detection (LOD) and limit of quantification (LOQ). The proposed method showed linearity in the concentration range of 50 to 250 ppm for Bupropion. The linear regression equation of Bupropion was found to be y = 6E+06x + 91344 and correlation coefficient value was found to be 0.997 indicating a high degree of linearity for the drug. The limit of detection (LOD) of bupropion was 0.5 ppm and limit of quantification (LOQ) was 2.0 ppm. The low values of %recovery and %C.V. showed that the method is precise within the acceptance limit of 5% (according to ICH guidelines).      

2020 ◽  
Vol 13 (4) ◽  
pp. 362-373
Author(s):  
Gayathri Nallathambi ◽  
V Sekar ◽  
Surendra kumar.M

The aim of the study is to develop some new analytical method development and Validation of Quantitative Estimation of Anti-depressant Drug Vilazodone by UV and HPLC was found to be simple, specific, precise, accurate, rapid and economical. The method was developed and validated as per ICH guidelines, concerning accuracy, precision, linearity, ruggedness, limit of detection, limit of quantification and robustness and forced degradation studies. The GRACE ODS phenyl column (4.6 x 150mm,5μm) column was maintained at an ambient temperature and 232 nm λ max conditions. The mixture of di-potassium hydrogen phosphate with buffer (pH 7.4) and methanol in proportion 60:40v/v mobile phase was used in the flow rate of 1 ml/min. All validation methods shows good reproducibility and good recovery. The mean recoveries was found in the range between 99.6-99.9%. with % RSD values were within 2. The limit of detection and limit of quantification were found to be 0.05 μg/ml and 0.01 μg/ml respectively. The method was found to be having suitable application in routine laboratory analysis with high degree of accuracy and precision.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 28-34
Author(s):  
K. Vijaya Sri ◽  
M. Shiva Kumar ◽  
A. Sravani ◽  

The RP-HPLC were developed and validated for the estimation of lurasidone HCl as per ICH guidelines. A simple, fast, accurate and precise RP-HPLC method was developed by using methanol: water containing 0.01% ortho phosphoric acid in the ratio of 70:30 (V/V). The method was developed in Eclipse C18 column (100 mm × 4.6 mm, 3.5 μm particle size). The method was found to be linear in the range of 2.5- 15µg/mL with a correlation coefficient value of 0.999. The accuracy studies of RP-HPLC method was performed at three different levels, i.e., 50%, 100%, and 150% and recovery was found to be in the range of 100.1-100.6% .The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.30-0.92. Satisfactory validation was also obtained from recovery (99.8%) studies, intra-day and interday precision and robustness 2%. The proposed method was found to be accurate, precise and rapid for the analysis of lurasidone.


Author(s):  
Pushpa Latha E. ◽  
Sailaja B.

Analytical UV derivative spectrophotometric method was developed and validated to quantify Rizatriptan Benzoate in pure drug and tablet dosage form. Based on the spectrophotometric characteristics of Rizatriptan Benzoate, a signal of zero (225nm), first (216nm), second (237nm), third (233nm), fourth (231nm) order derivative spectra were found to be adequate for quantification. The methods obeyed Beer's law in the concentration range of (0.1-360µg/ml) with square correlation coefficient (r2) of 0.999. The mean percentage recovery was found to be 100.01 ± 0.075. As per ICH guidelines the results of the analysis were validated in terms of linearity, precision, accuracy, limit of detection and limit of quantification, and were found to be satisfactory.


Author(s):  
Bhupender Tomar ◽  
Ankita Sharma ◽  
Inder Kumar ◽  
Sandeep Jain ◽  
Pallavi Ahirrao

A simple, precise, and accurate reverse phase high performance liquid chromatographic method (RP-HPLC) was developed and validated for the estimation of the combination of 5- Fluorouracil (5-FU) and Imiquimod in active pharmaceutical ingredients (APIs). The method was carried out on Phenomenex C18 (250 × 4.6mm I.D., 5𝜇m) using isocratic elution mode. The mobile phase was used as Acetonitrile: 10mM potassium dihydrogen orthophosphate: triethylamine (40:59.9:0.1, v/v, pH 4.5 with orthophosphoric acid) and Water: ACN (50:50 v/v) was used as a diluent. The concentration of solvents was 1-20µg/ml and the volume of injection was 20µl with the flow rate of 1.2ml/min. The retention times for 5-FU and Imiquimod were found to be 1.9±0.5 and 6.6±0.5 min respectively. The absorption maxima of 5FU and Imiquimod were found 267nm and 227nm respectively. The method was validated as per ICH guidelines. All the data were found within the specified limits. The limit of detection (LOD) and limit of quantification (LOQ) of 5- Fluorouracil were found to be 0.015μg/mL and 0.048 μg/mL, respectively, and Imiquimod was found to be 0.078μg/mL and 0.237μg/mL, respectively. The method developed in the present study was found to be sensitive, specific, and precise and can be applied for the simultaneous estimation of 5-FU and Imiquimod.


Author(s):  
Anas Rasheed ◽  
Osman Ahmed

A specific, precise, accurate ultra pressure liquid chromatography (UPLC) method is developed for estimation of chlophedianol hydrochloride in bulk drug and syrup dosage form. The method employed with Hypersil BDS C18 (100 mm x 2.1 mm, 1.7 μm) in a gradient mode, with mobile phase of methanol and acetonitrile in the ratio of 65:35 %v/v. The flow rate was 0.1 ml/min and effluent was monitored at 254 nm. Retention time was found to be 1.130±0.005 min. The method was validated in terms of linearity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ)in accordance with ICH guidelines. Linear regression analysis data for the calibration plot showed that there was good linear relationship between response and concentration in the range of 20-100 μg/ml respectively. The LOD and LOQ values were found to be 2.094(μg/ml)and 6.3466(μg/ml)respectively. No chromatographic interference from syrup excipients and degradants were found. The proposed method was successfully used for estimation of chlophedianol hydrochloride in syrup dosage form.


2020 ◽  
Vol 10 (6) ◽  
pp. 49-56
Author(s):  
Sneha Jagnade ◽  
Pushpendra Soni ◽  
Lavakesh Kumar Omray

The aim of present study was to investigate the development and validation of a green analytical method for the determination of aspirin and domperidone. Method Development and Validation for Estimation of Domperidone and Aspirin in bulk or formulation by using RP-HPLC. The RP-HPLC method was developed for estimation of Aspirin and Domperidone in synthetic mixture by isocratically using 10 mM KH2PO4: Acetonitrile (20:80) as mobile phase, Prontosil C-18 column (4.6 x 250 mm, 5μparticle size) column as stationary phase and chromatogram was recorded at 231 nm. Then developed method was validated by using various parameters such as, linearity, Range accuracy, precision repeatability, intermediate precision, robustness, limit of detection, limit of quantification. The proposed methods were found to be linear with correlation coefficient close to one. Precision was determined by repeatability, Intermediate precision and reproducibility of the drugs. The robustness of developed method was checked by changing in the deliberate variation in solvent. The result obtained shows the developed methods to be Cost effective, Rapid (Short retention time), Simple, Accurate (the value of SD and % RSD less than 2), Precise and can be successfully employed in the routine analysis of these drugs in bulk drug as well as in tablet dosage form. The Simplicity, Rapidly and Reproducibility of the proposed method completely fulfill the objective of this research work. Keywords: Asprin; Domperidone; HPLC; Ultra Violet; Validation


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (06) ◽  
pp. 59-66
Author(s):  
V Dhanunjayachary ◽  
◽  
V.L.S. Likhitha ◽  
Sri K. Vijaya ◽  
M. A Madhuri

The study was aimed at development and validation of RP-HPLC method for estimation of sofosbuvir in bulk, pharmaceutical dosage form and pharmaceutical industrial waste. The chromatographic separation was performed on Agilent Syncronis C 18 (100 mm × 4.6 mm, 5μm) column, with a mobile phase comprising of a mixture of methanol: acetonitrile: water (45:30:25 v/v/V). The flow rate was 1.0 mL/min with detection at 260 nm. Retention time of sofosbuvir was found to be 2.040 min. As per ICH guidelines, the method was validated for linearity, accuracy, limit of detection, limit of quantitation, precision, robustness and system suitability. Linearity was found to be in the range of 4-24 μg/mL with regression equation y = 675284.x + 49120 and correlation coefficient 0.999. The low % RSD values indicate the method to be accurate and precise. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.046 and 0.1400 μg/mL, respectively. The % recovery of tablets was found to be in the range of 99.9– 101.3%. It can be concluded that this validated HPLC method is easy, precise, accurate, sensitive and selective for estimation of sofosbuvir in bulk, tablet and applicable for analyses of in pharmaceutical industrial waste.


2019 ◽  
Vol 31 (1) ◽  
pp. 32-39
Author(s):  
Suman Shrivastava ◽  
Pooja Deshpande ◽  
S. J. Daharwal

Development of a method is crucial for discovery, development, and analysis of medicines in the pharmaceutical formulation. Method validation could also be thought to be one in all the foremost well-known areas in analytical chemistry as is reproduced within the substantial variety of articles submitted and presented in peer review journals every year. Validation of an analytical procedure is to demonstrate that it's appropriate for its intended purpose. Results from method validation are often wont to decide the quality, reliability and consistency of analytical results. Analytical methods need to be validated or revalidated. This review describes general approach towards validation process and validation parameters to be considered during validation of an analytical method. It also refers to various regulatory requirements like WHO, USFDA, EMEA, ICH, ISO/IEC. The parameters described here are according to ICH guidelines which include accuracy, precision, specificity, limit of detection, limit of quantification, linearity range and robustness.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Madhavi Patel ◽  
Shivangi Chauhan ◽  
Vishal Patel ◽  
Hardik Soni ◽  
Vikram Trivedi

Abstract Background Standardization of polyherbal medicine though being the need of the hour is a toilsome task. Among the various methods employed for quality control and standardization of polyherbal medicine, phytochemical profiling is of utmost importance as it signifies the quality as well as efficacy of the medicine. The work was aimed to develop and validate a simple, quick, and accurate RP-HPLC technique for simultaneous assessment of monoammonium glycyrrhizinate and sennoside-B in a polyherbal laxative tablet. The phytomarkers were effectively quantified by RP-HPLC system on C18 analytical column using gradient mobile phase consisting of phosphate buffer to acetonitrile with the detector wavelength set at 254 nm. This developed method was validated by determination of parameters like accuracy, linearity, precision, limit of detection, and quantification as well as robustness according to ICH guidelines. Results Calibration curve of both phytomarkers showed excellent linear correlation coefficients. LOD and LOQ were also calculated by equation. Precision studies were carried out using intra-day and inter-day intervals and RSD values were found to be less than 2.00%. The method was found to be accurate, which was evident from 98.96 to 101.39% and 99.17 to 100.67% recovery of monoammonium glycyrrhizinate and sennoside-B, respectively, when the formulation was spiked with the respective phytomarkers. Conclusion The validated method can be employed as standardization tool for herbal formulations with accuracy and precision. The developed method will assist in maintaining the good quality and batch to batch uniformity of polyherbal formulations containing Yashtimadhu, Swarnpatri, and Aragvadha as active ingredients.


Author(s):  
Sayyed Nazifa Sabir Ali ◽  
Lajporiya Mobina ◽  
Manjra Mehfuza ◽  
Patel Seema ◽  
Aejaz Ahmed ◽  
...  

Aims: To develop and validate a new, simple, rapid, precise, and accurate An Eco-friendly RP-HPLC and UV-Method Development and Validation for an estimation of Favipiravir in Bulk and pharmaceutical dosage form followed by Forced Degradation Studies. Study Design: This was employed for UV-visible (200-400 nm and 400-800 nm respectively) and RP-HPLC method development using C 18 inertsil column and optimization of variables for Favipiravir estimation in bulk and formulations. Place and Duration of the Study: The present work was carried out at Ali-allana College of Pharmacy, Akkalkuwa between the duration of November-2020 to February-2021. Methodology: UV-Spectroscopic method was developed for the estimation of Favipiravir in the bulk and pharmaceutical dosage form. The solvent selected for the Favipiravir UV analysis was water, the solution in a range of 2-10µg/ml was scanned in the UV region from 200-400 nm and the λmax value was determined. The RP-HPLC method was developed on inertsil ODS-3V C18 150 mm x 4.6mm x 5μ column using buffer pH 3.5: acetonitrile [90:10] as mobile phase at flow rate 1.0 ml/min and PDA detection at 358 nm. Results: The maximum absorbance was observed at 358 nm. The wavelength 358 nm was selected for further analysis of Favipiravir. The calibration curve was determined using drug concentrations ranging from 2-10 µg/ml. The % recovery for accuracy was 100.50-100.76%. The method was to be precise with a % RSD value 0.51-1.37 and 0.77-1.78 for intraday and Interday respectively. The limit of detection (LOD) and limit of quantification (LOQ) was found to be 0.0723 &0.219 µg/ml respectively by UV method. The RP-HPLC method was shown to be linear in the 50-250 μg/ml concentration range. The limit of detection (LOD) and limit of quantification (LOQ) was found to be 2.186 & 6.626 μg/ml respectively. The method was to be precise with a % RSD value 0.25-1.53 and 0.86-1.68 for intraday and inter-day respectively. Conclusion: Here we conclude that the developed UV and RP-HPLC methods are precise, accurate, sensitive, and reproducible for the quantitative estimation of Favipiravir bulk and its formulation. The developed method can be used by the pharmaceutical industries for the routine analysis of Favipiravir, in particular by UV and RP-HPLC. The main features of the proposed method are economic and eco-friendly with less retention time around 5.0 min.