scholarly journals The ASTRI-Horn telescope: comparison with the auxiliary UVscope measurements as calibration tool.

2021 ◽  
Author(s):  
Antonio Alessio Compagnino ◽  
Teresa Mineo ◽  
Maria Concetta Maccarone ◽  
Osvaldo Catalano ◽  
Domenico Impiombato ◽  
...  
Keyword(s):  
2006 ◽  
Vol 321-323 ◽  
pp. 451-454
Author(s):  
Joo Young Yoo ◽  
Sung Jin Song ◽  
Chang Hwan Kim ◽  
Hee Jun Jung ◽  
Young Hwan Choi ◽  
...  

In the present study, the synthetic signals from the combo tube are simulated by using commercial electromagnetic numerical analysis software which has been developed based on a volume integral method. A comparison of the simulated signals to the experiments is made for the verification of accuracy, and then evaluation of five deliberated single circumferential indication signals is performed to explore a possibility of using a numerical simulation as a practical calibration tool. The good agreement between the evaluation results for two cases (calibration done by experiments and calibration made by simulation) demonstrates such a high possibility.


Author(s):  
Francesco De Paola ◽  
Maurizio Giugni ◽  
Francesco Pugliese

2019 ◽  
Vol 47 (14) ◽  
pp. e81-e81
Author(s):  
Eguzkine Ochoa ◽  
Verena Zuber ◽  
Nora Fernandez-Jimenez ◽  
Jose Ramon Bilbao ◽  
Graeme R Clark ◽  
...  

Abstract Bisulfite amplicon sequencing has become the primary choice for single-base methylation quantification of multiple targets in parallel. The main limitation of this technology is a preferential amplification of an allele and strand in the PCR due to methylation state. This effect, known as ‘PCR bias', causes inaccurate estimation of the methylation levels and calibration methods based on standard controls have been proposed to correct for it. Here, we present a Bayesian calibration tool, MethylCal, which can analyse jointly all CpGs within a CpG island (CGI) or a Differentially Methylated Region (DMR), avoiding ‘one-at-a-time' CpG calibration. This enables more precise modeling of the methylation levels observed in the standard controls. It also provides accurate predictions of the methylation levels not considered in the controlled experiment, a feature that is paramount in the derivation of the corrected methylation degree. We tested the proposed method on eight independent assays (two CpG islands and six imprinting DMRs) and demonstrated its benefits, including the ability to detect outliers. We also evaluated MethylCal’s calibration in two practical cases, a clinical diagnostic test on 18 patients potentially affected by Beckwith–Wiedemann syndrome, and 17 individuals with celiac disease. The calibration of the methylation levels obtained by MethylCal allows a clearer identification of patients undergoing loss or gain of methylation in borderline cases and could influence further clinical or treatment decisions.


1994 ◽  
Vol 30 (4) ◽  
pp. 181-190 ◽  
Author(s):  
René Dupont ◽  
Ole Sinkjær

The objective of the work presented is to demonstrate how computer based models can be used to improve the effluent quality from wastewater treatment plants by optimisation of the operation. The investigation was carried out in connection with pilot plant investigations at Damhusllen Wastewater Treatment Plant in order to establish the design basis for upgrading the treatment plants in the city of Copenhagen. Calibration of the model was done with thorough characterisation of the wastewater and the activated sludge as the primary calibration tool. Special attention was paid to the nitrification process, which by previous investigations was shown to be occasionally inhibited. Model constants for the nitrification process were detennined from experiments. Default constants were used for nearly all other constants. The pilot plant was optimized with the calibrated model. Different operational strategies for improvement of the denitrification process were tested. The denitrification process was operated relatively poorly at the time for the optimisation. The calibration showed that it was possible to calibrate the model using the characterization of the wastewater and the activated sludge as the primary calibration tool. Further it was shown that the calihrated model could be used as a tool for optimising the operation of the pilot plant. The suggested operation correlated well with the practical realisable operation.


2017 ◽  
Vol 40 ◽  
pp. 97-103 ◽  
Author(s):  
David Clases ◽  
Marvin Birka ◽  
Michael Sperling ◽  
Andreas Faust ◽  
Uwe Karst
Keyword(s):  
Icp Ms ◽  

Sign in / Sign up

Export Citation Format

Share Document