scholarly journals Is TEVAR Really Needed for Uncomplicated Type B Aortic Dissection?

Author(s):  
Sven Zhen Cian Patrick Tan ◽  
Hazem Elsantawy ◽  
Amr Abdelhaliem

Thoracic endovascular aortic repair (TEVAR) has quickly become the mainstay of treatment for acute aortic dissection, in particular cases of acute complicated Stanford Type B dissection (co-TBAD). Necessarily, TEVAR carries with it the risk of postoperative complications, including stroke and renal failure. As a result, the management of patients with uncomplicated type B aortic dissection (un-TBAD), which is generally accepted as being less severe, are safely managed via optimal medical therapy (OMT) alone. However, despite OMT, patients with un-TBAD are at substantial risk of severe disease progression requiring delayed intervention. The cost-benefit ratio associated with TEVAR for un-TBAD is therefore of key interest. Howard and colleagues produced a fascinating systematic review and meta-analysis investigating the clinical outcomes of TEVAR for complicated and uncomplicated TBAD. Their data suggests that there is no significant difference in in-hospital mortality or 5-year survival between TEVAR for un-TBAD and co-TBAD, although the 30-day mortality rate appeared to be higher in the co-TBAD cohort. Patients with co-TBAD appeared to also be at a higher risk of postoperative stroke and TEVAR endoleak, while un-TBAD patients were at a higher risk of postoperative renal failure. Further prospective research into these relationships are recommended to fully elucidate the comparative efficacies of TEVAR for un-TBAD and co-TBAD.

2019 ◽  
Vol 27 (1) ◽  
pp. 145-152 ◽  
Author(s):  
Ahmed Eleshra ◽  
Tilo Kölbel ◽  
Giuseppe Panuccio ◽  
Fiona Rohlffs ◽  
E. Sebastian Debus ◽  
...  

Purpose: To report a single-center experience with thoracic endovascular aortic repair (TEVAR) for complicated acute type B aortic dissection (cATBAD) comparing patients with vs without end-organ ischemia. Materials and Methods: Between November 2010 and December 2017, 64 patients (mean age 64.8±12.5 years; 49 men) underwent TEVAR for cATBAD. Patients were grouped into 2 cohorts: nonischemic (39, 61%) patients with unrelenting pain, early progressive aortic dilatation, uncontrolled hypertension, or rupture, and ischemic (25, 39%) patients with visceral, renal, lower extremity, or spinal cord hypoperfusion. Results: Mean time from diagnosis to treatment was 7.5 days (range 1–32) in the nonischemic group vs 2.3 days (range 1–14) days in the ischemic group (p=0.007). Fourteen (56%) of 25 ischemic cATBAD patients had stents implanted in the renovascular branch vessels, while 4 (16%) patients had stents implanted in the iliac arteries. When branch vessel cannulation failed, fenestrations were made in the intimal flap to improve perfusion of the involved branch (n=5). In the nonischemic group, 3 arteries were stented owing to atherosclerotic stenosis. Technical success was achieved in 62 (97%) of 64 patients; despite stenting, 2 patients had low renal artery perfusion on final angiography. There were no statistically significant differences in early or late outcomes between the nonischemic vs ischemic cATBAD patients. Six (9%) patients died within 30 days: 2 (5%) in the nonischemic group vs 4 (16%) in the ischemic group. Major complications (1 stroke, 2 cases of paraplegia, 1 retrograde type A dissection, and 1 case of bowel ischemia) occurred only in the nonischemic group. The mean follow-up was 28 months. Late endoleaks were observed in 3 (8%) nonischemic patients and 1 (4%) ischemic patient. Reinterventions were required in 7 (18%) nonischemic patients and 4 (16%) ischemic patients. Conclusion: TEVAR is an effective and safe method of treating cATBAD. Early intervention in ischemic cATBAD may have played a significant role in the lack of significant difference between ischemic and nonischemic cATBAD outcomes. Direct visceral reperfusion through branch vessel stenting during TEVAR may be crucial in achieving good outcomes in ischemic cATBAD.


Author(s):  
Chia-An Wu ◽  
Andrew Squelch ◽  
Zhonghua Sun

Aim: To determine a printing material that has both elastic property and radiology equivalence close to real aorta for simulation of endovascular stent graft repair of aortic dissection. Background: With the rapid development of three-dimensional (3D) printing technology, a patient-specific 3D printed model is able to help surgeons to make better treatment plan for Type B aortic dissection patients. However, the radiological properties of most 3D printing materials have not been well characterized. This study aims to investigate the appropriate materials for printing human aorta with mechanical and radiological properties similar to the real aortic computed tomography (CT) attenuation. Objective: Quantitative assessment of CT attenuation of different materials used in 3D printed models of aortic dissection for developing patient-specific 3D printed aorta models to simulate type B aortic dissection. Method: A 25-mm length of aorta model was segmented from a patient’s image dataset with diagnosis of type B aortic dissection. Four different elastic commercial 3D printing materials, namely Agilus A40 and A50, Visijet CE-NT A30 and A70 were selected and printed with different hardness. Totally four models were printed out and conducted CT scanned twice on a 192-slice CT scanner using the standard aortic CT angiography protocol, with and without contrast inside the lumen.Five reference points with region of interest (ROI) of 1.77 mm2 were selected at the aortic wall and intimal flap and their Hounsfield units (HU) were measured and compared with the CT attenuation of original CT images. The comparison between the patient’s aorta and models was performed through a paired-sample t-test to determine if there is any significant difference. Result: The mean CT attenuation of aortic wall of the original CT images was 80.7 HU. Analysis of images without using contrast medium showed that the material of Agilus A50 produced the mean CT attenuation of 82.6 HU, which is similar to that of original CT images. The CT attenuation measured at images acquired with other three materials was significantly lower than that of original images (p<0.05). After adding contrast medium, Visijet CE-NT A30 had an average CT attenuation of 90.6 HU, which is close to that of the original images with statistically significant difference (p>0.05). In contrast, the CT attenuation measured at images acquired with other three materials (Agilus A40, A50 and Visiject CE-NT A70) was 129 HU, 135 HU and 129.6 HU, respectively, which is significantly higher than that of original CT images (p<0.05). Conclusion: Both Visijet CE-NT and Agilus have tensile strength and elongation close to real patient’s tissue properties producing similar CT attenuation. Visijet CE-NT A30 is considered the appropriate material for printing aorta to simulate contrast-enhanced CT imaging of type B aortic dissection. Due to lack of body phantom in the experiments, further research with simulation of realistic anatomical body environment should be conducted.


2003 ◽  
Vol 10 (2) ◽  
pp. 244-248 ◽  
Author(s):  
Maartje C. Loubert ◽  
Victor P.M. van der Hulst ◽  
Cees De Vries ◽  
Kees Bloemendaal ◽  
Anco C. Vahl

Purpose: To report techniques for excluding the dilated false lumen associated with chronic type B aortic dissection following placement of a stent-graft in the true lumen. Case Reports: Two patients underwent stent-graft implantation for a dilated false lumen after chronic aortic dissection, but the false lumen was not excluded from the circulation by this procedure. The false lumen was obliterated in one case with Greenfield filters and detachable balloons placed above a renal artery orifice that was perfused via the false lumen. This acted like “a cork in the bottleneck” to block retrograde flow into the thoracic portion of the false lumen above the blockade. In the other patient, an occluder device was used as the “cork.” In both cases, a good result was obtained. The occluder device is preferred because deployment is more controllable. Conclusions: An occluder device may be used like a cork in a bottle to exclude the dilated false lumen in the thoracic aorta after a type B dissection.


Hearts ◽  
2020 ◽  
Vol 1 (1) ◽  
pp. 14-24
Author(s):  
Xun Yuan ◽  
Rachel E. Clough ◽  
Christoph A. Nienaber

Acute aortic dissection has an incidence of approximately half that of symptomatic abdominal and thoracic aneurysm of the aorta and more than twice the mortality of population-based controls. While urgent undelayed open surgery is the strategy of choice in proximal dissection, medical management has been the mainstay of treatment for uncomplicated distal or type B aortic dissection, but endovascular intervention is now considered a potential treatment option for all type B dissection due to its success in complicated cases. Endovascular repair can be technically demanding in aortic dissection, and timing of the repair can have a significant influence on anatomical and clinical outcome. Observational reports of feasibility and reasonable safety are flanked by only two randomised trials; the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) trial demonstrated improved remodelling in acute dissection and the INvestigation of STEnt grafts in patients with type B Aortic Dissections (INSTEAD) trial showed better long-term survival in patients treated endovascularly in the subacute phase. Meta-analyses and other large clinical studies have demonstrated mixed results. Due to some risks associated endovascular repair and the requirement of specialist aortic care (which is not always available), a pragmatic approach for current management could involve high intensity serial imaging in the acute phase of a type B aortic dissection, thereby identifying complicated cases for early intervention and selection of patients at high risk of disease progression for deferred endovascular management in the subacute phase within 90 days.


2016 ◽  
Vol 2016 ◽  
pp. 1-10
Author(s):  
Kuang-Ming Liao ◽  
Chung-Yu Chen ◽  
Shih-Han Wang ◽  
Jiann-Woei Huang ◽  
Chen-Chun Kuo ◽  
...  

Aortic dissection is a life-threatening condition. However, the use of medication to treat it remains unclear in our population, particularly in patients with a type B aortic dissection (TBAD) who do not receive surgery. This retrospective cohort study evaluated antihypertensive prescription patterns and outcomes in patients with nonsurgical TBAD. We reviewed the hospital records of patients with TBAD at a medical center in Taiwan from January 2008 to June 2013 to assess the baseline information, prescribing pattern, event rate, and clinical effectiveness of different antihypertensive treatment strategies. A Cox proportional hazards model was used to estimate outcomes in different antihypertensive strategies. The primary endpoints were all-cause mortality and hospital admission for an aortic dissection. We included 106 patients with a mean follow-up period of 2.75 years. The most common comorbidity was hypertension followed by dyslipidemia and diabetes mellitus. Study endpoints mostly occurred within 6 months after the index date. Over 80% of patients received dual or triple antihypertensive strategies. Patients treated with different treatment strategies did not have a significantly increased risk of a primary outcome compared with those treated with a monotherapy. We found no significant difference in the primary outcome following the use of different antihypertensive medication regimes.


Perfusion ◽  
2017 ◽  
Vol 33 (2) ◽  
pp. 156-159
Author(s):  
Chih-Hung Lai ◽  
Keng-Hao Chang ◽  
Szu-Ling Chang ◽  
Hui-Chih Lai ◽  
Wen-Lieng Lee ◽  
...  

Complicated type B dissection is associated with a high mortality rate due to malperfusion syndrome or progression of the dissection for which aggressive therapy with an endovascular or surgical intervention is recommended. Herein, we present a patient who received a successful percutaneous rescue intervention after three days of renal ischemia caused by a complicated type B dissection. This type of rescue of percutaneous intervention with branch vessel stenting appears to be useful in treating malperfusion syndrome caused by aortic dissection, even after a period of organ ischemia.


Sign in / Sign up

Export Citation Format

Share Document