scholarly journals Effects of different etching methods and bonding procedures on shear bond strength of orthodontic metal brackets applied to different CAD/CAM ceramic materials

2017 ◽  
Vol 88 (2) ◽  
pp. 221-226 ◽  
Author(s):  
S. Kutalmış Buyuk ◽  
Ahmet Serkan Kucukekenci

ABSTRACT Objective: To investigate the shear bond strength (SBS) of orthodontic metal brackets applied to different types of ceramic surfaces treated with different etching procedures and bonding agents. Materials and Methods: Monolithic CAD/CAM ceramic specimens (N = 120; n = 40 each group) of feldspathic ceramic Vita Mark II, resin nanoceramic Lava Ultimate, and hybrid ceramic Vita Enamic were fabricated (14 × 12 × 3 mm). Ceramic specimens were separated into four subgroups (n = 10) according to type of surface treatment and bonding onto the ceramic surface. Within each group, four subgroups were prepared by phosphoric acid, hydrofluoric acid, Transbond XT primer, and Clearfill Ceramic primer. Mandibular central incisor metal brackets were bonded with light-cure composite. The SBS data were analyzed using three-way analysis of variance (ANOVA) and Tukey HSD tests. Results: The highest SBS was found in the Vita Enamic group, which is a hybrid ceramic, etched with hydrofluoric acid and applied Transbond XT Adhesive primer (7.28 ± 2.49 MPa). The lowest SBS was found in the Lava Ultimate group, which is a resin nano-ceramic etched with hydrofluoric acid and applied Clearfill ceramic primer (2.20 ± 1.21 MPa). Conclusions: CAD/CAM material types and bonding procedures affected bond strength (P < .05), but the etching procedure did not (P > .05). The use of Transbond XT as a primer bonding agent resulted in higher SBS.

2012 ◽  
Vol 13 (4) ◽  
pp. 487-493 ◽  
Author(s):  
PV Girish ◽  
Uma Dinesh ◽  
CS Ramachandra Bhat ◽  
Pradeep Chandra Shetty

ABSTRACT Aim To evaluate and compare the shear bond strength of metal brackets bonded to ceramic surfaces using different conditioning methods and to assess the site of bond failure after debonding. Materials and methods A total of 70 ceramic surfaces were produced with uniform shape, size and composition. The samples were divided into 7 groups (each of 10 samples). Group 1 was the control group (untreated surface); in group 2 the surface were roughened with a diamond bur; in group 3 the surface were etched with hydrofluoric acid; in group 4 the surfaces were sandblasted; in group 5 the surfaces roughened with bur and silane applied; in group 6 the surfaces were etched with hydrofluoric acid and silane applied and in group 7 the surfaces were sandblasted and silane applied. To all the above groups, metal orthodontic brackets were bonded with light cure adhesive. The brackets were later stored in artificial saliva and incubated at 37°C (24 hours). The samples were then subjected to shear bond strength test using an Instron universal testing machine. The debonded porcelain surfaces were then studied under stereomicroscope to assess site of bond failure. Results Sandblasting the ceramic surface and silane application showed the highest bond strength. Stereomicroscope examination after debonding showed that the bond failure is at bracket-adhesive interface in four groups namely hydrofluoric acid, sandblasting, hydrofluoric acid with silane and sandblasting with silane. Conclusion Sandblasting with silane combination produced the highest shear bond strength, so it is a clinically suitable method for bonding orthodontic metal brackets onto ceramic surface. Clinical relevance Bonding orthodontic brackets to ceramic crowns of patients has been a tough task. In this study, different conditioning methods were used to treat the ceramic surfaces before bonding. The results showed that sandblasting the ceramic surface prior to application of silane produced the highest shear bond strength which is clinically suitable to reduce bond failures. How to cite this article Girish PV, Dinesh U, Bhat CSR, Shetty PC. Comparison of Shear Bond Strength of Metal Brackets Bonded to Porcelain Surface using Different Surface Conditioning Methods: An in vitro Study. J Contemp Dent Pract 2012;13(4):487-493.


2016 ◽  
Vol 19 (1) ◽  
pp. 76
Author(s):  
Cristiane Frantz Arend ◽  
André Gundel ◽  
Renésio Armindo Grehs ◽  
Vilmar Antônio Ferrazzo ◽  
Luiz Felipe Valandro

<p><strong>Objective – </strong>The aim of this study was evaluate the effect of etching with different hydrofluoric acid (HF) concentrations on the shear bond strength between glazed feldspathic ceramic and metal brackets. <strong>Materials and Methods</strong> – Seventy-five blocks of glazed feldspathic ceramic were produced and randomly allocated to 5 groups: <strong>Ctrl-</strong> silane application only; <strong>HF1-</strong> HF1%+silane; <strong>HF3- </strong>HF3%+silane; <strong>HF5-</strong> HF5%+silane; <strong>HF10-</strong> HF10%+silane (standard procedures:  etching for 1 min + washing + drying + silanization). Metal brackets for upper central incisors (Edgewise Standard) were bonded on the ceramic surface with the use of an adhesive system and light-cured composite resin (Transbond<sup>TM</sup> XT, 3M). The specimens were aged for 60 days (thermocycling: 10000x at 5-55 °C; stored in distilled water at 37 °C). Shear testing was performed, and specimens were classified for their Adhesive-Remnant-Index (ARI). Topographical inspection and contact angle analysis of the etched ceramic surfaces were performed. Data were statistically analyzed using the non-parametric Kruskal-Wallis test. One-way ANOVA and post-hoc Tukey’s tests were applied to the contact angle data (p &lt; 0.05). <strong>Results</strong> – No significant difference was detected between the shear bond strength of the groups; but surface etching had a significant influence on the contact angle results (p &lt; 0.00001). The control group presented the highest mean contact angle (61.8 ± 17.2°). All specimens showed adhesive failure at the resin-ceramic interface. <strong>Conclusion –</strong> The tested HF concentrations did not significantly influence the obtained shear bond strength of metal brackets adhered to glazed feldspathic ceramic surfaces.</p><p><strong>Keywords</strong></p><p>Ceramics; Hydrofluoric acid; Adhesion; Brackets; Silanization.</p>


2020 ◽  
Vol 23 (3) ◽  
Author(s):  
Shahd Taha Mandil ◽  
Hesham Katamish ◽  
Tarek Salah

Objective: The aim of this study is to assess the effect of Er,Cr:YSGG laser on the shear bond strength (SBS) and surface topography of two CAD/CAM ceramic materials bonded with self-adhesive resin cement. Material and methods: sixty ceramic CAD/CAM discs were obtained, 30 lithium disilicate (IPS Emax) and 30 hybrid resin ceramic (Vita Enamic). The Slices were allocated into six groups (n=10) according to ceramic material and surface treatment; Group (LD-C): IPS Emax treated with 9% hydrofluoric acid(HF), Groups (LD-P1) and (LD-P2): IPS Emax treated with Er,Cr:YSGG laser with parameters 1.5 W and 2.5 W, respectively. Group (RC-C): Vita Enamic treated with 9% hydrofluoric acid (HF), Groups (RC-P1) and (RC-P2): Vita Enamic treated with Er,Cr:YSGG laser with parameters 1.5 W and 2.5 W, respectively. All samples were cemented with self-adhesive resin cement and thermocycled for 5000 cycles. The SBS was measured using a universal testing machine and the mean values (MPa) were analyzed using Two-way (ANOVA) (P ≤ 0.05) and Bonferroni’s post-hoc test. Results: RC-C (16.55) showed highest SBS followed by LD-C (13.79), which revealed no statistically significant difference with RC-P1 (12.33) and RC-P2 (11.2). The lowest SBS values were found with LD-P1 (2.7) and LD-P2 (2.1). SEM analysis revealed Vita Enamic to have the highest surface roughness. Fracture pattern analysis showed adhesive failure with IPS Emax groups and mixed failure with Vita Enamic groups. Conclusion: Er,Cr:YSGG laser irradiation with the parameters used did not increase SBS of IPS Emax and Vita Enamic with composite resin compared to HF acid etching.KeywordsEr,Cr:YSGG laser; Shear bond strength; Surface treatment; Ceramic materials.


2015 ◽  
Vol 20 (4) ◽  
pp. 51-56 ◽  
Author(s):  
João Paulo Fragomeni Stella ◽  
Andrea Becker Oliveira ◽  
Lincoln Issamu Nojima ◽  
Mariana Marquezan

OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding.METHODS: Four experimental groups (n = 13) were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid etching followed by silane application; G2 = 37% liquid phosphoric acid etching, no rinsing, followed by silane application; G3 = 10% hydrofluoric acid etching alone; and G4 = 10% hydrofluoric acid etching followed by silane application. After surface conditioning, metal brackets were bonded to porcelain by means of the Transbond XP system (3M Unitek). Samples were submitted to shear bond strength tests in a universal testing machine and the surfaces were later assessed with a microscope under 8 X magnification. ANOVA/Tukey tests were performed to establish the difference between groups (α= 5%).RESULTS: The highest shear bond strength values were found in groups G3 and G4 (22.01 ± 2.15 MPa and 22.83 ± 3.32 Mpa, respectively), followed by G1 (16.42 ± 3.61 MPa) and G2 (9.29 ± 1.95 MPa). As regards surface evaluation after bracket debonding, the use of liquid phosphoric acid followed by silane application (G2) produced the least damage to porcelain. When hydrofluoric acid and silane were applied, the risk of ceramic fracture increased.CONCLUSIONS: Acceptable levels of bond strength for clinical use were reached by all methods tested; however, liquid phosphoric acid etching followed by silane application (G2) resulted in the least damage to the ceramic surface.


2021 ◽  
Author(s):  
Elaheh Beyabanaki ◽  
Reza Eftekhar Ashtiani ◽  
Marjan Feizy ◽  
Amirali Zandinejad

2016 ◽  
Vol 27 (6) ◽  
pp. 734-738 ◽  
Author(s):  
Natália Regina Santos de Matos ◽  
Ana Rosa Costa ◽  
Heloísa Cristina Valdrighi ◽  
Américo Bortolazzo Correr ◽  
Silvia Amélia Vedovello ◽  
...  

Abstract The aim of this study was to evaluate the effect of silanes, thermal cycling and acid etching on the shear bond strength (SBS) of metallic brackets to feldspathic ceramic. Feldspathic ceramic cylinders (Groups 1, 2, 5 and 6) were etched for 60 s with 10% hydrofluoric acid and Groups 3, 4, 7 and 8, without acid etching. Two layers of silane Clearfil Ceramic Primer (CCP, Groups 1 to 4) and two layers of RelyX Ceramic Primer (RCP, groups 5 to 8) were applied and dried for 60 s. Brackets were bonded to the cylinders with Transbond XT and light-activated for 40 s with Bluephase G2. All specimens were stored in deionized water at 37 °C for 24 h, and the specimens of groups 1, 3, 5 and 7 were submitted to 7,000 thermal cycles (5 °C/55 °C). After storage, the SBS test was performed at a crosshead speed of 1 mm/min. Data were subjected to three-way ANOVA and Tukey's post hoc test (α=0.05). The adhesive remnant index (ARI) was evaluated at 8x magnification. The SBS of CCP was significantly greater than of RCP (p<0.05), with or without thermal cycling. Thermal cycling significantly reduced the SBS (p<0.05). The groups submitted to acid etching showed significantly higher SBS than those without acid etching (p<0.05). In conclusion, thermal cycling reduced SBS for all groups. The best ceramic surface treatment for bracket bonding was achieved by acid etching and CCP silane. The ARI results showed predominance of score 0 for all groups.


2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Mustafa Mehmet Özarslan ◽  
Özlem Üstün ◽  
Ulviye Sebnem Buyukkaplan ◽  
Çağatay Barutcigil ◽  
Nurullah Türker ◽  
...  

Adult orthodontics may confront problems related to the bonding performance of orthodontic brackets to new generation restorative materials used for crown or laminate restorations. The aim of the present study was to investigate the shear bond strength of ceramic brackets to two new generation CAD/CAM interpenetrating network composite and nanoceramic composite after different surface treatments. Er,Cr:YSGG Laser, hydrofluoric acid (9%), sandblasting (50 μm Al2O3), and silane were applied to the surfaces of 120 CAD/CAM specimens with 2 mm thickness and then ceramic brackets were bonded to the treated surfaces of the specimens. Bond strength was evaluated using the shear bond strength test. According to the results, CAD/CAM block types and surface treatment methods have significant effects on shear bond strength. The lowest bond strength values were found in the specimens treated with silane (3.35 ± 2.09 MPa) and highest values were found in the specimens treated with sandblast (8.92 ± 2.77 MPa). Sandblasting and hydrofluoric acid surface treatment led to the most durable bonds for the two types of CAD/CAM blocks in the present study. In conclusion, different surface treatments affect the shear bond strength of ceramic brackets to CAD/CAM interpenetrating network composite and nanoceramic composite. Among the evaluated treatments, sandblasting and hydrofluoric acid application resulted in sufficient bonding strength to ceramic brackets for both of the CAD/CAM materials.


2017 ◽  
Vol 46 (3) ◽  
pp. 179-183
Author(s):  
Fernando Guerra SÁEZ ◽  
Ana Rosa COSTA ◽  
Adriana Simoni LUCATO ◽  
Ana Paula Terossi de GODOI ◽  
Lourenço CORRER-SOBRINHO ◽  
...  

Abstract Objective To evaluate in vitro the effect of different treatments of the ceramic surface and thermal cycling on the shear bond strength (SBS) of metallic brackets bonded to feldspathic ceramic. Material and method Ceramic cylinders were divided into four groups (n=4) according to the treatment of ceramic surface: G1-Clearfil Ceramic Primer silane and Transbond XT (CCPT); G2-etched with 10% hydrofluoric acid (HFA) for 60 s, CCP and Transbond XT (ACCPT); G3-etched with 10% HFA for 60 s, Ambar Adhesive and Transbond XT (AAAT); and, G4 - etched with 10% HFA for 60 s, RelyX Ceramic Primer silane -RCP, adhesive primer Transbond and Transbond XT (ACPPT). Brackets were bonded to the cylinders with Transbond XT and light-activated for 40 s with LED Radii Plus. All specimens were stored in deionized water at 37 °C for 24 h, and two cylinders from each group were subject to 7,000 thermal cycles in a thermal cycler (5 °C/55 °C). After storage and thermal cycling, the SBS test was performed at a crosshead speed of 1 mm/min. Data were subjected to two-way ANOVA and Tukey’s post hoc test (α=0.05). Result The SBS of ACCPT was significantly higher than the other groups (p<0.05). The specimens submitted to thermal cycling showed significantly lower SBS than those without thermal cycling (p<0.05), regardless the ceramic surface treatment. The ARI showed predominance of score 0 for all groups. Conclusion Acid etching, CCP silane and Transbond XT method obtained the best results for bracket bonding. Thermal cycling reduced SBS for all groups. Score 0 was predominant for ARI in all groups.


Sign in / Sign up

Export Citation Format

Share Document