scholarly journals Trial of Stress-Related Index Measurement under Confinement Stress

Author(s):  
Yuichi OI ◽  
Yasuhito HIRAI ◽  
Shotaro DOKI ◽  
Yuh OHTAKI ◽  
Daisuke HORI ◽  
...  
2016 ◽  
Author(s):  
Panagiotis Tziogkidis ◽  
Dionisis Philippas ◽  
Alexandros Leontitsis

2021 ◽  
Vol 13 (6) ◽  
pp. 3219
Author(s):  
Hynek Lahuta ◽  
Luis Andrade Pais

This contribution presents results from a series of compression and undrained triaxial tests to study the mechanical behavior of dump clay from the north of Bohemia. The use of these materials as a foundation for construction can’t be achieved without the adoption of some precautions. This comes from embankment, formed by digging the ground (altered claystone), up to the level of coal mining which is in a sub horizontal stratigraphic layer. A potential static liquefaction behavior was observed in undrained tests for high confinement stress. A structural collapse was noticed with the results obtained in the triaxial test. This collapse is characterized by an unexpected large decrease in deviator and mean effective stress. The soils formed have strength properties that are potentially dangerous. These concepts can improve the use of these kinds of soils in geotechnical engineering work. It continues and expands the results obtained in previous research, especially the future problematic use of these materials as the foundation soil for line or building structures.


Photonics ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 199
Author(s):  
Yu-Cheng Lin ◽  
Liang-Yü Chen

The generation of lossy mode resonances (LMR) with a metallic oxide film deposited on an optical fiber has attracted the attention of many applications. However, an LMR-based optical fiber sensor is frangible, and therefore it does not allow control of the temperature and is not suited to mass production. This paper aims to develop a temperature-controlled lossy mode resonance (TC-LMR) sensor on an optical planar waveguide with an active temperature control function in which an ITO film is not only used as the LMR resonance but also to provide the heating function to achieve the benefits of compact size and active temperature control. A simple flat model about the heat transfer mechanism is proposed to determine the heating time constant for the applied voltages. The TC-LMR sensor is evaluated experimentally for refractive index measurement using a glycerol solution. The heating temperature functions relative to the controlled voltages for water and glycerol are obtained to verify the performance of the TC-LMR sensor. The TC-LMR sensor is a valuable sensing device that can be used in clinical testing and point of care for programming heating with precise temperature control.


Sign in / Sign up

Export Citation Format

Share Document