Clinical Evaluation of Self-etch and Total-etch Adhesive Systems in Noncarious Cervical Lesions: A Two-year Report

2013 ◽  
Vol 38 (5) ◽  
pp. 477-487 ◽  
Author(s):  
JO Burgess ◽  
R Sadid-Zadeh ◽  
D Cakir ◽  
LC Ramp

SUMMARY Objective: The purpose of this study was to compare the clinical performance of two self-etch dental adhesives with Single Bond Plus, a traditional one-bottle total-etch dental adhesive, for the restoration of noncarious cervical lesions. Materials and Methods: A total of 156 restorations were placed in noncarious cervical lesions with a minimum depth of 1.5 mm. Patients had no chronic periodontal disease and had normal salivary function. Each patient received restorations on three teeth, each bonded with either Adper Single Bond Plus, Adper Easy Bond, or Adper Scotchbond SE dental adhesive. All lesions were restored with Filtek Supreme Plus composite resin. All teeth were isolated with a rubber dam, received a short enamel bevel, and were cleaned with flour of pumice. The adhesives and resin composite were applied following the manufacturers' instructions. Restorations were clinically evaluated at baseline, six months, one year, and two years using modified US Public Health Service criteria. Results: Two-year retention was recorded as 97.3%, 90.5%, and 95.2%, for Single Bond Plus, Scotchbond SE, and Easy Bond, respectively. Statistical analysis did not show a significant difference (p>0.05) in clinical performance between any of the three adhesives after a period of two years.

2020 ◽  
Vol 45 (5) ◽  
pp. 473-483 ◽  
Author(s):  
CAGA Costa ◽  
NLG Albuquerque ◽  
JS Mendonça ◽  
AD Loguercio ◽  
VPA Saboia ◽  
...  

Clinical Relevance At 24 months, the dentin pretreatment with epigallocatechin-3-gallate did not impair the clinical performance of the adhesive Single Bond Universal regardless of the bonding strategy used. SUMMARY Purpose: To evaluate the two-year effect of dentin pretreatment with epigallocatechin-3-gallate (EGCG) on the clinical performance of restorations of noncarious cervical lesions (NCCLs) with Single Bond Universal, applied in two different modes (self-etch and etch-and-rinse). Methods and Materials: In this randomized clinical trial, 33 volunteers were selected, and 156 NCCLs were assigned to four groups: ER, etch-and-rinse; ER-EGCG, 0.1% EGCG dentin pretreatment + etch-and-rinse; SE, self-etch; and SE-EGCG, 0.1% EGCG dentin pretreatment + self-etch. The NCCLs were restored with a nanofilled resin composite and evaluated at baseline and at six, 12, 18, and 24 months using FDI criteria for retention, marginal staining, marginal adaptation, caries, and postoperative sensitivity. Two evaluators were blinded to the treatments performed, and impressions were taken for resin replicas to allow indirect observations. Statistical analyses were performed with Kruskal-Wallis and McNemar tests with a significance level of 5%. Results: Six restorations (one from ER, two from SE, one from ER-EGCG, and two from SEEGCG) were lost at 24 months with no significant differences (p>0.05). The retention rates were 97.0% (ER and ER-EGCG), 94.1% (SE), and 94.2% (SE-EGCG). For marginal adaptation, a significant difference was detected between the baseline and 24 months for the SE group (p=0.0313). There were no statistical differences among all other evaluated criteria at 24 months, neither for each group at baseline nor for 24-month comparisons (p>0.05). Conclusions: The pretreatment with EGCG provided no benefit in the clinical performance of the adhesive regardless of the bonding strategy used. In addition, it adds an additional required step to the restorative procedure.


2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Babacar Faye ◽  
Mouhamed Sarr ◽  
Khaly Bane ◽  
Adjaratou Wakha Aidara ◽  
Seydina Ousmane Niang ◽  
...  

This study evaluated the one-year clinical performance of a one-step, self-etch adhesive (Optibond All-in-One, Kerr, CA, USA) combined with a composite (Herculite XRV Ultra, Kerr Hawe, CA, USA) to restore NCCLs with or without prior acid etching. Restorations performed by the same practitioner were evaluated at baseline and after 3, 6, and 12 months using modified USPHS criteria. At 6 months, the recall rate was 100%. The retention rate was 84.2% for restorations with prior acid etching, but statistically significant differences were observed between baseline and 6 months. Without acid etching, the retention rate was 77%, and no statistically significant difference was noted between 3 and 6 months. Marginal integrity (93.7% with and 87.7% without acid etching) and discoloration (95.3% with and 92.9% without acid etching) were scored as Alpha or Bravo, with better results after acid etching. After one year, the recall rate was 58.06%. Loss of pulp vitality, postoperative sensitivity, or secondary caries were not observed. After one year retention rate was of 90.6% and 76.9% with and without acid conditioning. Optibond All-in-One performs at a satisfactory clinical performance level for restoration of NCCLs after 12 months especially after acid etching.


2017 ◽  
Vol 42 (4) ◽  
pp. E102-E110 ◽  
Author(s):  
E Karaman ◽  
AR Yazici ◽  
G Ozgunaltay ◽  
I Ustunkol ◽  
A Berber

SUMMARY Objective: To compare the 24-month clinical performance of two different resin composites in class II slot restorations. Methods and Materials: Thirty-seven patients having at least two approximal carious lesions were enrolled in the study. A total of 116 teeth (58 pairs) were restored with either a silorane-based composite (Filtek Silorane) and its self-etch adhesive (Silorane Adhesive System, 3M ESPE) or a methacrylate-based packable resin composite (X-tra Fil) and its self-etch adhesive (Futurabond NR, VOCO GmbH) according to the toss of a coin. The restorations were evaluated at baseline and at six-, 12-, and 24-month recalls by two calibrated examiners according to the modified US Public Health Service criteria. The comparison of the two restorative materials for each category was performed with the Pearson chi-square test. Within group differences of the materials at different recall times were compared using the Cochran Q and Friedman tests. Bonferroni-adjusted McNemar test was used when significant difference was found (p<0.05). Results: After 24 months, no statistically significant differences were found between the two restorative materials for the criteria evaluated. Conclusions: Both silorane- and methacrylate-based resin composites showed clinically acceptable performance in class II slot restorations after 24 months.


2012 ◽  
Vol 65 (3-4) ◽  
pp. 115-121
Author(s):  
Milica Premovic ◽  
Bojana Ramic ◽  
Igor Stojanac ◽  
Milan Drobac ◽  
Ljubomir Petrovic

Introduction. The aim of this one-year prospective clinical study was to evaluate the treatment results of compomer restorations (Dyract? eXtra/ Dentsply/De Trey, Konstanz, Germany) with a single step self-etching dental adhesive (Xeno? III Dentsply/De Trey, Konstanz, Germany) used for restoring class V lesions (non-carious and primary carious cervical lesions). Material and Methods. A total number of 62 class V restorations (n = 62) were placed by one dentist in 30 patients on incisors, canines and premolars. The fillings were placed due to different indications: non-carious cervical defects (n = 32) and primary carious lesions (n = 30). The restorations were evaluated by a single-blind design, according to the Modified United States Public Health Service system 6 and 12 months following the placement. The following were evaluated: retention, marginal integrity, marginal discoloration, wear, postoperative sensitivity and secondary caries. The statistical analysis compared the ratings of each criteria between materials using the Pearson chi-square or Fisher?s exact test at a level of significance of 5% (p<0.05). Results. Two restorations of the non-carious lesion group were lost after 6 months, and after 12 months one restoration was lost in the group of primary carious lesions. There were no statistically significant differences between restorations for all evaluated criteria in both groups. Conclusion. The compomer restorations in combination with a single step self-etching dental adhesive showed acceptable clinical performance in Class V lesions after one year of clinical service.


2020 ◽  
Vol 45 (1) ◽  
pp. E11-E20
Author(s):  
AMO Correia ◽  
ALB Jurema ◽  
MR Andrade ◽  
ALS Borges ◽  
E Bresciani ◽  
...  

SUMMARY Purpose: This randomized clinical trial evaluated the influence of the occlusogingival distance (OGD) of noncarious cervical lesions (NCCLs) on the clinical performance of a regular bulk-fill resin composite and a regular nanofilled resin composite. Methods and Materials: A total of 140 restorations were randomly placed in 77 participants by one operator. NCCLs were divided into four groups (n=35) according to OGD (1.5 mm±10% or 3 mm±10%) and resin composites (Filtek Bulk Fill Posterior [B] or Filtek Z350 XT [C]) used: 1.5 mm-B, 1.5 mm-C, 3 mm-B, and 3 mm-C. A two-step self-etch adhesive (Clearfil SE Bond) was applied following manufacturer instructions in all restorative procedures. Restorations were polished 1 week after placement. Clinical evaluation was performed at baseline (7 days), 6 months, and 1 year by two calibrated examiners, according to the modified US Public Health Service criteria evaluating fractures/retention, marginal staining, marginal adaptation, recurrence of caries, anatomic form, postoperative sensitivity, and surface texture. The Kruskal-Wallis test was used for intergroup comparison in each follow-up; the Friedman analysis of variance, followed by the least significant difference test (multiple comparisons) was used for intragroup comparison between baseline and follow-up times (α=0.05). Results: Two restorations were lost at 12 months (1 for 1.5 mm-B and 1 for 3 mm-B). The retention rates at 12 months were 100% for 1.5 mm-C, 97% for 1.5 mm-B, 100% for 3 mm-C; and 97% for 3 mm-B, with no statistical difference among the groups (p=0.570). At 12 months, a statistically significant difference was found among the follow-up times for the same group (1.5 mm-B, 1.5 mm-C, and 3 mm-B) regarding the marginal staining criterion; moreover, the 3 mm-C group showed a significant difference from 6 months. No significant difference was found for the other parameters. Conclusion: Both resin composites showed acceptable clinical performance, and the OGD of NCCLs did not influence the clinical performance of resin composite restorations after 12 months.


2021 ◽  
Author(s):  
TP Matos ◽  
TA Hanzen ◽  
R Almeida ◽  
C Tardem ◽  
MC Bandeca ◽  
...  

SUMMARY Objectives: To evaluate the 5-year clinical performance of two-step etch-and-rinse adhesives in noncarious cervical lesions (NCCL). Methods and Materials: The sample comprised 35 adults with at least two similar-sized NCCL. Seventy restorations were placed, according to one of the following groups: Adper Single Bond 2 (SB) and Ambar (AM). The restorations were placed incrementally using a resin composite (Opallis). The restorations were evaluated at baseline and after 6 and 18 months and 5 years using some items of the FDI criteria. The differences in the ratings of the two materials after 6 months, 18 months, and 5 years were performed with Friedman repeated measures ANOVA by rank and McNemar test for significance in each pair (α=0.05). Results: Five patients did not attend the 60-month recall. No significant differences were observed between the materials for any criteria evaluated. Twenty-one restorations failed (12 for SB and 9 for AM) after 60 months. Thus, the retention rate for SB at 60 months were 55.6% for SB and 71% for AM (p=0.32). After 60 months, 12 restorations (6 for SB and 6 AM) showed some loss of marginal adaptation (p=1.0). Slight marginal discoloration was observed in 10 restorations (6 for SB and 4 AM; p=0.91). Five restorations (2 for SB and 3 for AM) showed recurrences of caries (p=1.0). Conclusions: Both two-step etch-and-rinse adhesives—Adper Single Bond 2, a polyalkenoic acid-containing adhesive, and Ambar, a 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing adhesive—showed acceptable clinical performance after 60 months.


2016 ◽  
Vol 695 ◽  
pp. 3-11 ◽  
Author(s):  
Sanda Mihaela Popescu ◽  
Mihaela Jana Ţuculină ◽  
Horia Octavian Manolea ◽  
Veronica Mercuţ ◽  
Monica Scrieciu

AIM: To evaluate the clinical performance of adhesive restorations of resin-modified glass-ionomer cements (RMGIC) compared with of resin composite (RC), and RMGIC liner base laminated with a resin composite in non carious cervical lesions (NCCL).METHODS: The randomized clinical trial included 45 patients (25-65 year-old), with at least two similar sized NCCL on premolars. After sample size calculation, 220 restorations were placed, according to one of the following groups: (G1) Resin-modified glass-ionomer cement (Vitremer); (G2) a resin composite and an adhesive layer (Versaflo); (G3) RMGIC liner base laminated with a resin composite (Vitremer and Versaflo). The restorations were clinically followed every 6 months for up to 24 months using the USPHS modified criteria for clinical evaluation. Survival estimates for restoration longevity were evaluated using the Kaplan-Meier method. Log-rank test (P< 0.05) was used to compare the differences in the success rate according to the type of the restorative material.RESULTS: At the end of 24 months, 172 restorations were evaluated in 37 patients, with a recall rate of 82.22%. The type of restorative material used did not influence the longevity of the restorations. The survival rates for the follow-up were similar regarding the number of restored surfaces and the tooth (upper or lower premolar). Estimated survival rates of the restorations were 100%, 100%, 98,25% and 90,69% at 6, 12, 18 and 24 months of clinical evaluations, respectively. A statistically significant difference was observed between RMGIC and RC or RMGIC laminated with RC for color match, but no other significant difference was observed among the three types of restorations.CONCLUSIONS: The survival rates were similar for the three types of restorations in NCCL. Different types of materials demonstrated acceptable clinical performance in non-carious cervical lesions.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


2014 ◽  
Vol 39 (6) ◽  
pp. 578-587 ◽  
Author(s):  
TC Fagundes ◽  
TJE Barata ◽  
E Bresciani ◽  
SL Santiago ◽  
EB Franco ◽  
...  

SUMMARY Purpose The purpose of this study was to comparatively assess the seven-year clinical performance of a one-bottle etch-and-rinse adhesive with resin composite (RC) and resin-modified glass ionomer (RMGI) restorations in noncarious cervical lesions. Methods and Materials One operator placed 70 restorations (35 restorations in each group) in 30 patients under rubber dam isolation without mechanical preparation. The restorations were directly assessed by two independent examiners, using modified US Public Health Service criteria at baseline and 6, 12, 24, 60, and 84 months. The obtained data were tabulated and statistically analyzed using the Fisher and McNemar tests. A difference was significant if p&lt;0.05. Results Twenty patients were available for recall after seven years (66.6%), and 25 RC and 26 RMGI restorations out of 70 restorations were evaluated. Excellent agreement was registered for all criteria between examiners (κ≥0.85). Alfa and bravo scores were classified as clinically acceptable. The McNemar test detected significant differences within RC restorations between baseline and seven-year evaluations for anatomic form, marginal integrity, and retention (p&lt;0.05). For RMGI restorations, a significant difference was identified for marginal integrity (p&lt;0.05). As to material comparison, the Fisher exact showed a better retention performance for RMGI restorations than for RC restorations (p&lt;0.05). Twelve composite restorations were dislodged (52.0% retention) and three ionomer restorations were lost (88.5% retention). The cumulative success rate for RC and RMGI was 30% and 58.1%, respectively. Conclusions After seven years of service, the clinical performance of RMGI restorations was superior to that of the adhesive system/resin composite restorations in this study.


2016 ◽  
Vol 41 (5) ◽  
pp. 520-530 ◽  
Author(s):  
T Suzuki ◽  
T Takamizawa ◽  
WW Barkmeier ◽  
A Tsujimoto ◽  
H Endo ◽  
...  

SUMMARY The purpose of this study was to determine the enamel bond durability of three universal adhesives in different etching modes through fatigue testing. The three universal adhesives used were Scotchbond Universal, Prime&Bond Elect universal dental adhesive, and All-Bond Universal light-cured dental adhesive. A single-step self-etch adhesive, Clearfil S3 Bond Plus was used as a control. The shear bond strength (SBS) and shear fatigue strength (SFS) to human enamel were evaluated in total-etch mode and self-etch mode. A stainless steel metal ring with an internal diameter of 2.4 mm was used to bond the resin composite to the flat-ground (4000-grit) tooth surfaces for determination of both SBS and SFS. For each enamel surface treatment, 15 specimens were prepared for SBS and 30 specimens for SFS. The staircase method for fatigue testing was then used to determine the SFS of the resin composite bonded to the enamel using 10-Hz frequencies for 50,000 cycles or until failure occurred. Scanning electron microscopy was used to observe representative debonded specimen surfaces and the resin-enamel interfaces. A two-way analysis of variance and the Tukey post hoc test were used for analysis of the SBS data, whereas a modified t-test with Bonferroni correction was used for the SFS data. All adhesives in total-etch mode showed significantly higher SBS and SFS values than those in self-etch mode. Although All-Bond Universal in self-etch mode showed a significantly lower SBS value than the other adhesives, there was no significant difference in SFS values among the adhesives in this mode. All adhesives showed higher SFS:SBS ratios in total-etch mode than in self-etch mode. With regard to the adhesive systems used in this study, universal adhesives showed higher enamel bond strengths in total-etch mode. Although the influence of different etching modes on the enamel-bonding performance of universal adhesives was found to be dependent on the adhesive material, total-etch mode effectively increased the enamel bond strength and durability, as measured by fatigue testing.


Sign in / Sign up

Export Citation Format

Share Document