Premolar Axial Wall Height Effect on CAD/CAM Crown Retention

2016 ◽  
Vol 41 (6) ◽  
pp. 666-671 ◽  
Author(s):  
C Gillette ◽  
R Buck ◽  
N DuVall ◽  
S Cushen ◽  
M Wajdowicz ◽  
...  

SUMMARY Objective: To evaluate the significance of reduced axial wall height on retention of adhesively luted, all-ceramic, lithium disilicate premolar computer-aided design/computer-aided manufacturing (CAD/CAM) crowns based on preparations with a near ideal total occlusal convergence of 10°. Methods: Forty-eight recently extracted premolars were randomly divided into four groups (n=12). Each group received all-ceramic CAD/CAM crown preparations featuring axial wall heights of 0, 1, 2, and 3 mm, respectively, all with a 10° total occlusal convergence. Scanned preparations were fitted with lithium disilicate all-ceramic crowns that were luted with a self-etching resin cement. Specimens were tested to failure at a 45° angle to the tooth long axis with failure load converted to megapascals (MPa) based on the measured bonding surface area. Mean data were analyzed using analysis of variance/Tukey's post hoc test (α=0.05). Results: Lithium disilicate crowns adhesively luted on preparations with 0 axial wall height demonstrated significantly less failure resistance compared with the crowns luted on preparations with axial wall heights of 1 to 3 mm. There was no failure stress difference between preparations with 1 to 3 mm axial wall height. Conclusions: Under conditions of this study, adhesively luted lithium disilicate bicuspid crowns with a total occlusal convergence of 10° demonstrated similar failure resistance independent of axial wall height of 1 to 3 mm. This study provides some evidence that adhesion combined with an ideal total occlusal convergence may compensate for reduced axial wall height.

2019 ◽  
Vol 45 (4) ◽  
pp. 416-425
Author(s):  
LH Raposo ◽  
PS Borella ◽  
DC Ferraz ◽  
LM Pereira ◽  
MS Prudente ◽  
...  

Clinical Relevance Marginal misfit of monolithic lithium disilicate ceramic crowns obtained from a chairside computer-aided design/computer-aided manufacturing system is affected after successive millings using a single diamond bur set. This fact can be critical for the longevity of indirect restorations. SUMMARY Objectives: This laboratory study aimed to assess the effect of successive crown millings on the marginal misfit of monolithic full-ceramic restorations obtained from two lithium disilicate systems, with a single diamond bur set used for each material in a chairside computer-aided design/computer-aided manufacturing (CAD/CAM) unit. Methods and Materials: Initially, 36 standardized composite resin dies were produced by additive manufacturing from a three-dimensional model of a right mandibular first molar with full-crown preparation generated in CAD software. Individual ceramic crowns were obtained in a chairside CAD/CAM unit (CEREC MC XL) for each composite resin die according to the ceramic system (IPS e.max CAD and Rosetta SM; n=18). Two new diamond burs were used as a set for obtaining the crowns in each experimental group (ceramic systems), and the milling periods were defined after three crown millings (T0-T6), when the diamond bur set of each system was removed for morphologic characterization using scanning electron microscopy (SEM). The marginal misfit of the crowns was assessed through coronal and sagittal micro-tomographic sectioning, in the vertical and horizontal directions of the ceramic crowns seated on their respective resin dies. The collected data were tabulated and subjected to one-way analysis of variance and Tukey's honestly significant difference test (α=0.05). Results: SEM images showed changes in the superficial morphology of the diamond bur sets, with progressive loss of the diamond granules after the successive millings of crowns for both experimental groups. Significant differences were detected in the marginal misfit of the crowns from both ceramic systems at the different milling periods (p<0.001). Conclusions: Diamond burs deteriorated after successive crown millings for both lithium disilicate ceramic systems. The marginal misfit of the crowns obtained increased with the successive use of the CAD/CAM diamond bur set employed for milling each ceramic material. In addition, new milling of full lithium disilicate ceramic crowns can be inappropriate after 11 successive millings for IPS e.max CAD and 12 for Rosetta SM, due to the increased marginal misfit observed under the parameters tested.


2013 ◽  
Vol 07 (S 01) ◽  
pp. S115-S118 ◽  
Author(s):  
Rafael Ferrone Andreiuolo ◽  
Carlos Eduardo Sabrosa ◽  
Katia Regina H. Cervantes Dias

ABSTRACTThe use of bi-layered all-ceramic crowns has continuously grown since the introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia cores. Unfortunately, despite the outstanding mechanical properties of zirconia, problems related to porcelain cracking or chipping remain. One of the reasons for this is that ceramic copings are usually milled to uniform thicknesses of 0.3-0.6 mm around the whole tooth preparation. This may not provide uniform thickness or appropriate support for the veneering porcelain. To prevent these problems, the dual-scan technique demonstrates an alternative that allows the restorative team to customize zirconia CAD/CAM frameworks with adequate porcelain thickness and support in a simple manner.


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Jae-Hong Kim ◽  
Seunghan Oh ◽  
Soo-Hyuk Uhm

The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice—before and after crystallization—using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a pairedt-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α=0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P<0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120μm, which is the clinically acceptable threshold.


2021 ◽  
Vol 6 (11) ◽  

Background: Most dental trauma in children and adolescents involve anterior tooth fractures. Advancements in ceramics technology and in computer-aided design/computer-aided manufacturing (CAD/CAM) systems, have led to the technological abilities to produce single all-ceramic crowns with high biocompatibility, esthetics, and optimal mechanical properties. However, there is no information regarding the use of this technique in children. Case report:Treatment of extensive crown fractures on an 11 years old patient using a chairside CAD/CAM technology. The teeth were scanned and the restorations were fabricated using the manufacturing unit of the CAD/CAM system and glazed to the appropriate tooth color. At a follow up visits the restorations kept their strength and esthetic appearance (one year follow up). Conclusion: The digital restoration treatment is especially suitable for treating children with dental trauma. It has the advantage of better esthetic, functional and durable results compering to conventional restorations, and it often requires only a single session.


2021 ◽  
Vol 13 (4) ◽  
pp. e7296
Author(s):  
Magna Andréa Rabêlo Diógenes ◽  
Francisca Tauliane Lemos de Castro ◽  
Samara Kelly da Silva Cavalcante ◽  
Ana Carolina Matias Dinelly Pinto ◽  
Pedro Henrique Chaves Isaias ◽  
...  

Objetivo: Revisar acerca do efeito da fumaça do cigarro, associada ou não à escovação, na rugosidade superficial e na microdureza de uma cerâmica vítrea de dissilicato de lítio “Computer-Aided Design/Computer-Aided Manufacturing” (CAD/CAM). Métodos: Pesquisaram-se os descritores cadastrados no MeSH “lithium disilicate”, “smoking”, “CAD CAM”, “brushing”, “rough”, “hardness”, combinados entre si pelo operador booleano “AND”, na base de dados PubMed nos últimos 5 anos. Resultados: De acordo com a pesquisa, foram encontrados 625 artigos e selecionados 12 estudos in vitro. 5 estudos concluíram que as restaurações cerâmicas CAD/CAM apresentaram estabilidade de cor e de rugosidade da superfície, após escovação simulada e termociclagem.  4 estudos observaram que a escovação simulada e algumas bebidas aumentaram significativamente a rugosidade superficial da cerâmica de dissilicato de lítio. 3 estudos inferiram que a rugosidade superficial e a microdureza podem ser influenciadas pelos tratamentos de superfícies. Considerações finais: As cerâmicas de dissilicato de lítio CAD/CAM possuem propriedades satisfatórias em relação a sua resistência e estética, após exposição à fumaça do cigarro, associada ou não com a escovação.


2016 ◽  
Vol 41 (5) ◽  
pp. 531-540 ◽  
Author(s):  
B Stawarczyk ◽  
D Awad ◽  
N Ilie

SUMMARY Determining the amount of blue light (360-540nm) passing through nine monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) materials depends on material thickness, initial irradiance, and the distance between the curing unit and the specimen's surface. A total of 180 specimens of two thicknesses (1 mm and 2 mm, n=10/subgroup) were fabricated from TelioCAD, VITA CAD-Temp (VCT), experimental nanocomposite, LAVA Ultimate (LU), VITA ENAMIC (VE), VITA MarkII (VM), IPS EmpressCAD (IEC), IPS e.maxCAD (IEM), and CELTRA DUO (CD). The irradiance passing through the CAD/CAM materials and thicknesses was measured using a light-emitting-diode curing unit with standard-power, high-power, and plasma modes by means of a USB4000 spectrometer. The curing unit was placed directly on the specimen's surface at 2- and 4-mm distances from the specimen's surface. Data were analyzed using a multivariate analysis and one-way analysis of variance with the post hoc Scheffé test (p&lt;0.05). The highest transmitted irradiance was measured for VM and LU, followed by VCT and IEC, while the lowest values showed VE, followed by IEM and CD. The highest transmitted irradiance was recorded by exposing the material to the plasma mode, followed by the high- and standard-power modes. The measured irradiance was decreased by increasing the specimen's thickness from 1 to 2 mm. Fewer differences were measured when the curing unit was placed at 0 or 2 mm from the specimen's surface, and the irradiance passing through the specimens was lower at a distance of 4 mm.


Prosthesis ◽  
2020 ◽  
Vol 2 (4) ◽  
pp. 325-332
Author(s):  
Kelly M. Suralik ◽  
Jie Sun ◽  
Chia-Yu Chen ◽  
Sang J. Lee

There has been an increase in utilizing 3D printers in dental restorations. The purpose of the study is to compare mechanical properties of 3D-printed prostheses to those of self-cured and/or computer-aided design-computer-aided manufacturing (CAD-CAM) restorations. A metal master typodont was prepared for the mandibular left sextant with implant analogs embedded at the first premolar and first molar positions with a missing second premolar. Three-unit provisional fixed dental prosthesis (FDP) was designed utilizing the 3Shape tooth library and forty-five uniform specimens were fabricated with different materials: self-cured poly(methyl methacrylate) (PMMA) (N = 15), milled PMMA CAD-CAM blocks (N = 15) and 3D-printed resin (N = 15). All specimens were tested using an Instron machine at a crosshead speed of 0.5 mm/min by an axial load on the occlusal surface of the second premolar pontic site. Statistical analysis was completed with Shapiro-Wilk, ANOVA and Tukey post-hoc tests. Mean fracture force was 300.61 N, 294.64 N and 408.49 N for self-cured PMMA, milled PMMA and 3D-printed resin, respectively. Mean force at FDP fracture of 3D-printed resin was significantly greater than the mean fracture force of either self-cured (p = 0.016, 95% CI [17.86, 197.91]) or milled (p = 0.010, 95% CI [23.83, 203.88]) PMMA.


Sign in / Sign up

Export Citation Format

Share Document