scholarly journals Quantitation of nitrofurantoin in human plasma by liquid chromatography tandem mass spectrometry

2013 ◽  
Vol 63 (2) ◽  
pp. 141-158 ◽  
Author(s):  
Dinesh S. Patel ◽  
Naveen Sharma ◽  
Mukesh C. Patel ◽  
Bhavin N. Patel ◽  
Pranav S. Shrivastav ◽  
...  

A reliable, selective and sensitive LC-MS/MS assay has been proposed for the determination of nitrofurantoin in human plasma. The analyte and nitrofurazone were extracted from 100 μL of human plasma via SPE on Strata-X 33 μm extraction cartridges. Chromatography was done on a BDS Hypersil C18 (100 mm × 4.6 mm, 5 μm) column under isocratic conditions. Quantitation was done using the multiple reaction monitoring (MRM) mode for deprotonated precursor to product ion transitions of nitrofurantoin (m/z 237.0 → 151.8) and nitrofurazone (m/z 197.0 → 123.9). The limit of detection and the lowest limit of quantitation of the method were 0.25 ng mL-1 and 5.00 ng mL-1, respectively, with a linear dynamic range of 5.00-1500 ng mL-1 for nitrofurantoin. The intra- -batch and inter-batch precision (RSD, %) was ≤ 5.8 %, while the mean extraction recovery was > 92 %. The method was successfully applied to a bioequivalence study of a 100 mg nitrofurantoin capsule formulation in 36 healthy subjects.

2012 ◽  
Vol 2012 ◽  
pp. 1-10 ◽  
Author(s):  
Dinesh S. Patel ◽  
Naveen Sharma ◽  
Mukesh C. Patel ◽  
Bhavin N. Patel ◽  
Pranav S. Shrivastav ◽  
...  

A reliable, rapid, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been proposed for the determination of rizatriptan in human plasma using sumatriptan as internal standard (IS). The analyte and IS were extracted from 300 μL human plasma via liquid-liquid extraction and the chromatography was achieved on Hypurity C18 (50 mm × 4.6 mm, 5 μm) column under isocratic conditions. Detection of rizatriptan and IS was done by tandem mass spectrometry, operating in positive ionization and multiple-reaction monitoring mode. The limit of detection and lower limit of quantitation of the method were 0.04 and 0.20 ng/mL, respectively, with a linear dynamic range of 0.20–60.0 ng/mL. The intrabatch and interbatch precision (% CV) was ≤8.4% while the mean extraction recovery was >78% across quality control levels. Bench top stability, freeze and thaw stability, processed sample stability, and long-term stability in plasma were evaluated at two quality control levels. It was successfully applied to a bioequivalence study of 10 mg rizatriptan orally disintegrating tablet formulation in 40 and 32 healthy Indian male subjects under fasting and fed conditions, respectively. The reproducibility in the measurement of study data was demonstrated by reanalysis of 254 incurred samples.


2019 ◽  
Vol 57 (8) ◽  
pp. 751-757
Author(s):  
Jiake He ◽  
Ning Li ◽  
Jiaqiu Xu ◽  
Jing Zhu ◽  
Yang Yu ◽  
...  

Abstract A simple, sensitive, specific, accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for determination of chlorzoxazone in human plasma was developed and validated to evaluate the pharmacokinetic characteristics of chlorzoxazone test or reference formulation. Sample preparation was achieved by one step protein precipitation and dilution with acetontrile. The chromatographic separation was performed at 40°C with a gradient mobile phase (0.3 mL/min) and a Shimadzu VP-ODS C18 analytical column (column size: 150 × 2.0 mm). TSQ quantum access triple-quadrapole MS/MS detection was operated in a negative mode by multiple reaction monitoring. Ion transitions at m/z 168.0→132.1 for chlorzoxazone and m/z 451.3→379.3 for repaglinide (internal standard) were used for the LC-MS/MS analysis. The calibration was linear (r ≥ 0.995) over the tested concentration range of 0.2–20 μg/mL for chlorzoxazone in plasma. Precision, accuracy, recovery, matrix effect and stability for chlorzoxazone were evaluated and were excellent within the range of tested concentrations. This method was successfully applied to a bioequivalence study in 20 healthy Chinese volunteers. This method could also contribute to the personalized medication and therapeutic drug monitoring of chlorzoxazone.


Author(s):  
Xi Luo ◽  
Xiu Jin Zhang ◽  
Wen Ling Zhu ◽  
Jin Ling Yi ◽  
Wen Gang Xiong ◽  
...  

Abstract A high performance liquid chromatography–tandem mass spectrometry assay for the determination of afatinib (AFT) in human plasma was established. A simple sample preparation of protein precipitation was used and separation was achieved on a C18 column by the gradient mixture of mobile Phase A of water (containing 0.1% ammonia) and the mobile Phase B of acetonitrile and water (V:V = 95:5, containing 0.2% ammonia). The multiple reaction monitoring mode was used to monitor the precursor-to-production transitions of m/z 486.2 → m/z 371.4 for AFT and m/z 492.2 → m/z 371.3 for AFT-d6 (internal standard) at positive ionization mode. The calibration curve ranged from 0.100 to 25.0 ng·mL−1 and the correlation coefficient was greater than 0.99. The intra- and inter-batch precision was less than or equal to 10.0%. Accuracy determined at four concentrations was in the range of 92.3–103.3%. In summary, our method was sensitive, simple and reliable for the quantification of AFT and was successfully applied to a bioequivalence study.


Author(s):  
Nirav P. Patel ◽  
Mallika Sanyal ◽  
Pranav S. Shrivastav ◽  
Bhavin N. Patel

Objective: A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been developed for the determination of celecoxib (CXB) in negative ionization mode.Methods: Celecoxib and celecoxib-D7 (CXB-D7) as internal standard (IS) were extracted from 300 µl human plasma by solid-phase extraction using strata-X SPE cartridges. Chromatographic separation was achieved on ACE C8-300 (50 × 4.0 mm, 3.0 μm) column using methanol-1.0 mmol ammonium acetate solution in 80:20 (v/v) ratio. The protonated precursor to product ion transitions studied for CXB and CXB-D7 were m/z 380.0 → 315.9 and 387.0 → 323.0, respectively.Results: The limit of detection (LOD) and lower limit of quantitation of the method were 2.50 and 10.0 ng/ml respectively with a linear dynamic range of 10.0-4000 ng/ml for CXB. The intra-batch and inter-batch precision (% CV) and mean relative recovery across quality control levels is<7.2 % and 85.5 % respectively. Matrix effect in human plasma, expressed as IS-normalized matrix factor ranged from 0.99-1.03.Conclusion: The method was successfully applied in healthy subjects using a single dose of 400 mg celecoxib capsules under fasting and fed conditions. The reproducibility in the measurement of study data is demonstrated by incurred sample reanalysis.


Bioanalysis ◽  
2019 ◽  
Vol 11 (13) ◽  
pp. 1291-1302 ◽  
Author(s):  
Ping Du ◽  
Pengfei Li ◽  
Rui Zhao ◽  
Hongchuan Liu ◽  
Lihong Liu

Aim: Olanzapine (OLZ) is the first-line, cost–effectiveness treatment for schizophrenia in China. A quantitative ultrahigh performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for determination of OLZ in human plasma was developed. Results: LC separation was achieved on Waters XBrige C18 column. ESI+ was involved and multiple reaction monitoring transitions were at m/z 313.2→256.1 for OLZ and m/z 316.2→256.1 IS (d3-OLZ). The linear range was 0.1–20 ng/ml with LLOQ of 0.1 ng/ml. Accuracy and precision were within 10%. The validated method was successfully applied to a bioequivalence study of OLZ disintegrating tablets at dose of 5 mg with 100% reproducibility evaluated by incurred sample reanalysis. Conclusion: A robust validated method was developed for quantitation of OLZ in human plasma.


2013 ◽  
Vol 634-638 ◽  
pp. 1586-1590
Author(s):  
Su Fang Wang ◽  
Shou Jie Zhang ◽  
Chun Hong Dong ◽  
Guo Qing Wang ◽  
Jun Feng Guo ◽  
...  

A method for simultaneous determination of residuals of four herbicides and pesticides, simazine, carboxin, diflubenzuron and rotenone, in Chinese green tea was developed. In the proposed method, the tea powder was placed in a centrifuge tube with a plug, extracted in saturated aqueous sodium chloride solution and acetonitrile, agitated using vortex oscillator, and then centrifuged 5 min at 4000 rpm. The supernatant solution was purified by primary secondary amine (PSA) sorbent, C18 power, and graphitized carbon black powder, respectively. Then the purified extracts were dissolved with acetonitrile:0.1% formic acid aqueous solution (40:60, V/V) and agitated, filtered using a syringe with 0.22 μm nylon filter prior to UPLC-MS/MS analysis. The UPLC analysis was performed on an ACQUITY UPLC® HSS T3 column (2.1 mm×100 mm, 1.8 µm), using acetonitrile-0.1% formic acid as mobile phase with the flow rate as 0.3 mL•min-1. Injection volume was 10 µL. Positive ionization mode was applied, and the ions were monitored in the multiple reaction monitoring (MRM) mode with curtain gas 0.069 MPa, collision gas 0.052 MPa, ESI ion spray voltage 5000 V, temperature 550 °C, nebulizer gas 0.24 MPa, and turbo gas 0.28 MPa. The limit of detection (LOD) and limit of quantitation (LOQ) of the proposed method are 1 μg•kg-1and 5 μg•kg-1, respectively. The average recoveries of the four pesticides at 10, 20, and 50 µg•kg-1spiking levels range from 77.4% to 95.3%. TheSupersSuperscript textcript textrelative standard deviation (RSD) (n=6) range form 11.83% to 4.52%.


2019 ◽  
Vol 8 (3) ◽  
pp. 671-674

Bioanalytical methods for bioequivalence studies require high sensibility and rapidity due to the large number of samples and the low plasma concentration of drugs. The present study aimed to develop and validate a high-performance liquid chromatography method to quantify cimetidine (CMT) in human plasma and to apply it in a bioequivalence study. Spiked plasma of 500 µl (l, m and h concentration) was used for the assay. The HPLC injection volume was 20μl of the reconstitute sample where, 2 ml of ethyl acetate used for extraction purposes. Cimetidine was prepared separately for low (80 ng/ml), medium (2000 ng/ml) and high (3600 ng/ml) concentrations and internal standard (ranitidine) concentration was 3000 ng/ml. Freeze thawing and long terms stability were conducted at -25º c. The individual calibration curve for spiked standards was linear with R2= 0.99. The inaccuracy values for QC samples were within 15% of the actual value and not more than 20% for the LOQ. The limit of quantitation (LOQ) was 40 ng/ml, which was also the lowest concentration of cimetidine that was quantitated with the variability of 5.9%. The within day precision and between day precision for LOQ were 10.8 and 5.9 respectively. The retention time for the analyte was 4.1-4.5 minutes during the within a day and between day results. The mean % inaccuracy values for low, medium and high concentration were 6.8, 5.6 and 7.8 respectively for within day and 2.4, 6.1 and 7.9 respectively for between days. The within day and between day % inaccuracy for LOQ concentration was 12.4 and 5.5 respectively. The mean recoveries for low, medium and high concentration of cimetidine were 80.2, 70.9 and 74.2. The overall mean recovery for cimetidine was 75.1%. The maximum inaccuracy for freeze thaw cycle and long term stability samples for low, medium and high was found with CV less than 15% for all concentrations, indicating that cimetidine is stable. The developed method was precise and accurate and was suitable to be applied for the bioequivalence study of cimetidine.


Author(s):  
Jongsook Rhee ◽  
Jihyun Kim ◽  
Moonhee Jang ◽  
Ilchung Shi ◽  
Sangki Lee

Abstract This study evaluated hair samples from 28 subjects who had measurable ketamine levels among the samples requested from 2016 to 2017 into Seoul Institute National Forensic Service in Korea. Ketamine in the hair was extracted by using a solution of 1% hydrochloric acid in methanol for 16 h. Extracts were analyzed using gas chromatography mass spectrometry (GC-MS) or liquid chromatography tandem mass spectrometry (LC-MS-MS). LC-MS-MS method was validated by determining the limit of detection (LOD), limit of quantitation (LOQ), linearity, intra- and inter-accuracy, precision, and matrix effects. In 59 ketamine-positive hair or hair segments from 28 ketamine abusers, the ketamine concentration was found to be in the range of 0.011-335.8 ng/mg (mean, 13.6; median, 1.8), and the norketamine concentration was found to be in the range of 0.001-35.7 ng/mg (mean, 7.5; median, 0.44). The ratio of norketamine to ketamine concentration in hair was in the range of 0.01-1.46 (mean, 0.34; median, 0.26). The distribution of ketamine concentration in hair samples was as follows: 0.01-0.1 ng/mg in 11 samples (18.6%), 0.1-5 ng/mg in 33 samples (55.9%), 5-10 ng/mg in 4 samples (6.8%), 10-15 ng/mg in 2 samples (3.4%), 15-20 ng/mg in 4 samples (6.8%), 40-45 ng/mg in 2 samples (3.4%), 45-50 ng/mg in 1 samples 1.7%) and &gt;100 ng/mg in only 2 samples (3.4%). In the hair of ketamine-abusers, 26 of 28 subjects had simultaneously ketamine with detectable levels of other controlled drugs, including MDMA (n=9), MA (n=3), MDMA/MA (n=3), MDMA/PMA (n=3), MDMA/PMA/MA (n=2), cocaine (n=1), and other drugs (n=5, propofol, zolpidem or benzodiazepines). In most of the hair samples were detected ketamine with other controlled drugs: MDMA (60.7%), MA (28.6%), PMA(17.9%), zolpidem (17.9%), and propofol (14.3%) in the frequency of abuse. In conclusion, most of the ketamine-abusers (92.9%) would be polydrug abusers, who were concomitantly abusing other controlled substances.


Sign in / Sign up

Export Citation Format

Share Document