scholarly journals Morphometric Analysis of Greater Palatine Canal via Cone-Beam Computed Tomography

2018 ◽  
Vol 22 (3) ◽  
pp. 150-156
Author(s):  
Melih Özdede ◽  
Elif Yıldızer Keriş ◽  
Bülent Altunkaynak ◽  
İlkay Peker

SummaryBackground/Aim: The morphology of the greater palatine canal (GPC) should be determined preoperatively to prevent possible complications in surgical procedures required maxillary nerve block anesthesia and reduction of descending palatine artery bleeding. The purpose of this investigation was to evaluate the GPC morphology.Material and Methods: In this retrospective cross-sectional study, cone-beam computed tomography images obtained for various causes of 200 patients (females, 55%; males, 45%) age ranged between 18 and 86 (mean age±standard deviation=47±13.6) were examined. The mean length, mean angles of the GPC and anatomic routes of the GPC were evaluated.Results: The mean length of the GPC was found to be 31.07 mm and 32.01 mm in sagittal and coronal sections, respectively. The mean angle of the GPC was measured as 156.16° and 169.23° in sagittal and coronal sections. The mean angle of the GPC with horizontal plane was measured as 113.76° in the sagittal sections and 92.94° in the coronal sections. The mean GPC length was longer in males than in females.Conclusions: The results of this study showed that the most common pathway of the GPC was “first inferior, and then anterior-inferior direction” in sagittal plane and “first medial-inferior, then inferior direction” in coronal plane.

2019 ◽  
Vol 2019 ◽  
pp. 1-7
Author(s):  
Andre Luiz Ferreira Costa ◽  
Aline Kataki Paixão ◽  
Bianca Costa Gonçalves ◽  
Celso Massahiro Ogawa ◽  
Thiago Martinelli ◽  
...  

This study aimed to investigate the olfactory fossa according to the Keros classification using cone beam computed tomography. This cross-sectional study analysed cone beam computed tomography images selected from a database belonging to a radiology centre. The scans of 174 healthy patients were analysed by using the Xoran software. Gender, age, and side were correlated with the Keros classification. The mean age of the 174 patients was 45.3 years. The most prevalent Keros classification was type II (65.52%), followed by type III (20.69%) and type I (13.79%). No significant differences were found between Keros classification and the variables age, right side (pvalue = 0.4620), and left side (pvalue = 0.5709). There were also no significant differences between gender and the variables right side (pvalue = 0.1421) and left side (pvalue = 0.2136). Based on these results, we suggest that cone beam computed tomography can be recommended for analysis of the anterior skull base. Keros type II was the most prevalent type in our sample.


2019 ◽  
Vol 10 (1) ◽  
pp. 22-25
Author(s):  
Moiza Ijaz ◽  
Saira Ibrahim ◽  
Ayesha Aslam ◽  
Abdul Rehman ◽  
Sameena Younis ◽  
...  

Objective: To evaluate the type and depth of lingual concavity in posterior mandible using pre-treatment CBCT (Cone Beam Computed Tomography) images for dental implants. Study Design and Setting: A cross-sectional study was designed and conducted on pre-treatment CBCT scans of 75 patients at Armed Forces Institute of Dentistry, Rawalpindi, Pakistan from February 2018 to November 2018. Methodology: Pre-treatment CBCT scans of 75 patients were selected and following parameters were measured: type of ridge (undercut, parallel, convex), ridge width, ridge height, depth of lingual concavity, concavity angle, and location of the undercut. Data was analyzed using SPSS version .24. Post-stratification Mann-Whitney U test was used for effect modifiers, while Kruskal-Wallis test was used to compare study parameters between groups. P value <0.05 was taken as significant. Results: A mean concavity depth of 1.17±1.40 mm was observed while majority (46.7%) of the CBCT images presented with undercut type ridge. No significant difference was observed between males and females for any study parameter. Conclusion: Undercut ridges were frequently observed, posing a threat of lingual perforation during implant placement. Pre-operative assessment of implant site using CBCT can serve as a reliable method to avoid such complications


Urolithiasis ◽  
2021 ◽  
Author(s):  
R. A. Kingma ◽  
M. J. H. Voskamp ◽  
B. H. J. Doornweerd ◽  
I. J. de Jong ◽  
S. Roemeling

AbstractCone beam computed tomography (CBCT) provides multiplanar cross-sectional imaging and three-dimensional reconstructions and can be used intraoperatively in a hybrid operating room. In this study, we investigated the feasibility of using a CBCT-scanner for detecting residual stones during percutaneous nephrolithotomy (PCNL). Intraoperative CBCT-scans were made during PCNL procedures from November 2018 until March 2019 in a university hospital. At the point where the urologist would have otherwise ended the procedure, a CBCT-scan was made to image any residual fragments that could not be detected by either nephroscopy or conventional C-arm fluoroscopy. Residual fragments that were visualized on the CBCT-scan were attempted to be extracted additionally. To evaluate the effect of this additional extraction, each CBCT-scan was compared with a regular follow-up CT-scan that was made 4 weeks postoperatively. A total of 19 procedures were analyzed in this study. The mean duration of performing the CBCT-scan, including preparation and interpretation, was 8 min. Additional stone extraction, if applicable, had a mean duration of 11 min. The mean effective dose per CBCT-scan was 7.25 mSv. Additional extraction of residual fragments as imaged on the CBCT-scan occurred in nine procedures (47%). Of the follow-up CT-scans, 63% showed a stone-free status as compared to 47% of the intraoperative CBCT-scans. We conclude that the use of CBCT for the detection of residual stones in PCNL is meaningful, safe, and feasible.


2014 ◽  
Vol 15 (6) ◽  
pp. 740-745
Author(s):  
Mojdeh Mehdizadeh ◽  
Navid Ahmadi ◽  
Mahsa Jamshidi

ABSTRACT Objectives Exact location of the inferior alveolar nerve (IAN) bundle is very important. The aim of this study is to evaluate the relationship between the mandibular third molar and the mandibular canal by cone-beam computed tomography. Study design This was a cross-sectional study with convenience sampling. 94 mandibular CBCTs performed with CSANEX 3D machine (Soredex, Finland) and 3D system chosen. Vertical and horizontal relationship between the mandibular canal and the third molar depicted by 3D, panoramic reformat view of CBCT and cross-sectional view. Cross-sectional view was our gold standard and other view evaluated by it. Results There were significant differences between the vertical and horizontal relation of nerve and tooth in all views (p < 0.001). Conclusion The results showed differences in the position of the inferior alveolar nerve with different views of CBCT, so CBCT images are not quite reliable and have possibility of error. How to cite this article Mehdizadeh M, Ahmadi N, Jamshidi M. Evaluation of the Relationship between Mandibular Third Molar and Mandibular Canal by Different Algorithms of Cone-beam Computed Tomography. J Contemp Dent Pract 2014;15(6):740-745.


2019 ◽  
Vol 10 (2) ◽  
pp. 132-136
Author(s):  
Tahmineh Razi ◽  
Nader Vahdani Manaf ◽  
Morteza Yadekar ◽  
Sedigheh Razi ◽  
Shiva Gheibi

Objectives: One of the most important problems of cone-beam computed tomography (CBCT) imaging technique is the presence of dense objects, such as implants, amalgam fillings, and metal veneers, which result in beam-hardening artifacts. With an increase in the application of CBCT images and considering the problems in relation to cupping artifacts, some algorithms have been presented to reduce these artifacts. The aim was to present an algorithm to eliminate cupping artifacts from axial and other reconstructed CBCT images. Materials and Methods: We used CBCT images of NewTom VG imaging system (Verona, Italy, at Dentistry Faculty, Medical Sciences University, Tabriz, Iran) in which every image has a resolution of 366 × 320 in DICOM format. 50 images of patients with cupping artifacts were selected. Using Sobel edge detector and nonlinear gamma correction coefficient, the difference was calculated between the density of axial images in the main image and the image resulting from nonlinear gamma correction at the exact location of the radiopaque dental materials detected by Sobel. The points at which this density difference was out of a definite limit were treated as image artifacts and were eliminated from the main image by the inpainting method. Results: The resultant axial images, for producing reconstructed cross-sectional, panoramic images without cupping artifacts, were imported into NTT viewer V5.6 and utilized. Conclusions: With comparison, acquired images observed that the offering algorithm is practical and effective for reducing the cupping artifacts and preserving the quality of the reconstructed images. This algorithm does not need any additional equipment.


2021 ◽  
Vol 10 (38) ◽  
pp. 3413-3418
Author(s):  
Fatma Fayez Badr ◽  
Mohammed Abdulaziz Barayan ◽  
Fatima Mohammed Jadu ◽  
Hanadi Mohammed Khalifa

BACKGROUND Cone beam computed tomography (CBCT) was first introduced in 2008 and has since seen a tremendous growth in both private dental clinics and dental institutions. This has led to the normalization of CBCT use by general dentists. Therefore, it is essential to assess how and why general and specialist dentists use CBCT. The purpose of this study was to assess the knowledge, practice and attitude towards CBCT among general and specialist dentists working in the kingdom of Saudi Arabia. METHODS In this cross-sectional study, a questionnaire was electronically distributed via email and social media from October 2018 to September 2020. The self-administered questionnaire was divided into five segments: demographics, knowledge, current practice, training and attitude. RESULTS A total of 221 dentists filled the questionnaire including 85 general dentists and 135 post graduate students or specialists. The majority of dentists (81.9 %) demonstrated poor knowledge. Orthodontists and endodontists were most aware of CBCT terms. Most dentists (71.5 %) have a CBCT unit in their practice. Only 34.8 % received CBCT training, the majority of which was theoretical. A positive attitude was noted in 83.2 % of dentists by agreeing to a statement regarding CBCT justification. CONCLUSIONS Poor CBCT knowledge was evident in majority of dentists despite having CBCT in their practice. Dentists are highly aware of the importance of CBCT justification and professional interpretation; however, they lack basic knowledge and training related to this imaging modality. This highlights an institutional gap that policy makers should address in order to ensure the highest quality of patient care. KEY WORDS Cone Beam Computed Tomography; CBCT; Survey


Sign in / Sign up

Export Citation Format

Share Document