Geotechnical investigation through SP, Electrical Resistivity and GPR geophysical methods

Geotecnia ◽  
2016 ◽  
Vol 137 ◽  
pp. 141-155
Author(s):  
Herson Oliveira da Rocha ◽  
◽  
Lúcia Maria Costa e Silva ◽  
João Andrade dos Reis Júnior ◽  
◽  
...  
2021 ◽  
Vol 11 (6) ◽  
pp. 2448
Author(s):  
Alex Sendrós ◽  
Aritz Urruela ◽  
Mahjoub Himi ◽  
Carlos Alonso ◽  
Raúl Lovera ◽  
...  

Water percolation through infiltration ponds is creating significant synergies for the broad adoption of water reuse as an additional non-conventional water supply. Despite the apparent simplicity of the soil aquifer treatment (SAT) approaches, the complexity of site-specific hydrogeological conditions and the processes occurring at various scales require an exhaustive understanding of the system’s response. The non-saturated zone and underlying aquifers cannot be considered as a black box, nor accept its characterization from few boreholes not well distributed over the area to be investigated. Electrical resistivity tomography (ERT) is a non-invasive technology, highly responsive to geological heterogeneities that has demonstrated useful to provide the detailed subsurface information required for groundwater modeling. The relationships between the electrical resistivity of the alluvial sediments and the bedrock and the difference in salinity of groundwater highlight the potential of geophysical methods over other more costly subsurface exploration techniques. The results of our research show that ERT coupled with implicit modeling tools provides information that can significantly help to identify aquifer geometry and characterize the saltwater intrusion of shallow alluvial aquifers. The proposed approaches could improve the reliability of groundwater models and the commitment of stakeholders to the benefits of SAT procedures.


Geophysics ◽  
2021 ◽  
pp. 1-50
Author(s):  
Allan Haas ◽  
Dale F. Rucker ◽  
Marc T. Levitt

Industrialized sites pose challenges for conducting electrical resistivity geophysical surveys, as the sites typically contain metallic infrastructure that can mask electrolytic-based soil and groundwater contamination. The Hanford site in eastern Washington State, USA, is an industrialized site with underground storage tanks, piping networks, steel fencing, and other potentially interfering infrastructure that could inhibit the effectiveness of electrical resistivity tomography (ERT) to map historical and monitor current waste releases. The underground storage tanks are the largest contributor by volume to subsurface infrastructure and can be classified as reinforced concrete structures with an internal steel liner. Directly measuring the effective value for the electrical resistivity of the tank, i.e., the combination of individual components that comprise the tank’s shell, is not reasonably possible because they are buried and dangerously radioactive. Therefore, we indirectly assess the general resistivity of the tanks and surrounding infrastructure by developing synthetic ERT models with a parametric forward modeling study using a wide range of resistivity values from 1×10−6 to 1×104 ohm-m, which are equivalent to steel and dry rock, respectively. The synthetic models used the long-electrode ERT method (LE-ERT), whereby steel cased metallic wells surrounding the tanks are used as electrodes. The patterns and values of the synthetic tomographic models were then compared to LE-ERT field data from the AX tank farm at the Hanford site. This indirect method of assessing the effective resistivity revealed that the reinforced concrete tanks are electrically resistive and the accompanying piping infrastructure has little influence on the overall resistivity distribution when using electrically based geophysical methods for characterizing or monitoring waste releases. Our findings are consistent with nondestructive testing literature that also shows reinforced concrete to be generally resistive.


2018 ◽  
Vol 22 (3) ◽  
pp. 195-204 ◽  
Author(s):  
Sadegh Rezaei ◽  
Issa Shooshpasha ◽  
Hamed Rezaei

Today, geotechnical and geophysical techniques are used for landslide evaluation. Geotechnical methods provide accurate data, but are time consuming and costly. Geophysical techniques, however, are fast and inexpensive, yet their accuracy is lower than that of the geotechnical methods. Therefore, simultaneous use of geotechnical and geophysical methods provides a suitable solution for landslide evaluation. Availability of geotechnical and geophysical data makes it possible to investigate correlation between different parameters. Correlating geotechnical and geophysical parameters ends up lowering field investigation costs and enhancing subsurface survey speed in a landslide zone. In the present study, in order to evaluate Nargeschal landslide in Iran, ambient noise measurement, ERT survey, and geotechnical investigations were used. Once finished with data processing, the data obtained from geotechnical and geophysical investigations were correlated. These included SPT-N – electrical resistivity, soil moisture content – electrical resistivity, and SPT-N – shear wave velocity correlations. The correlations were examined using two methods, namely Spearman’s coefficient test and least square regression analysis. The results obtained from the two methods were in good agreement with one another. The correlations obtained in this study were of moderate to very strong strength and fell in the range of the results of previous studies. Investigation of the results indicated significant influences of ground water on electrical resistivity and soil stiffness on shear wave velocity. Results of this study can be used for soil classification and determination of mechanical and seismic characteristics of soil across various areas.


2014 ◽  
Vol 57 (1) ◽  
Author(s):  
Marco Marchetti ◽  
Vincenzo Sapia ◽  
Adriano Garello ◽  
Donatella De Rita ◽  
Alessandra Venuti

<p>The Vulci archeological site was object of interest by the Soprintendenza ai beni culturali dell’Etruria meridionale (Italian government department responsible for southern Etruria’s cultural heritage) since the beginning of the 20th century. In 2001, the Ministero dei Beni Culturali (Italian ministry of cultural heritage) along with the local authorities, opened a natural-archeological park. In this area, it lies most of the ancient Etruscan city of Velch (today known by its Latin name, Vulci) including the Osteria Necropolis that is the object of this study. Recently, new archaeological excavations were made and the local authorities needed major geological information about the volcanic lithotypes where the Etruscans used to build their necropolis. The aim of this study is to define the geological and geophysical characteristics of the rock lithotypes present in the Vulci park. For this purpose, a geological map of the area (1:10000) has been realized. Moreover, two different geophysical methods were applied: measurements of magnetic susceptibility and electrical resistivity tomography. Magnetic susceptibility analyses clearly identify magnetic contrasts between different lithotypes; the characteristics of the pyroclastic flow that originated the Sorano unit 2 and its vertical facies variations are well recorded by this parameter that along with lithostratigraphic observations provides information about the depositional conditions. Two electrical resistivity tomographies were performed, which show the Sorano unit 2 thickness to be of c. 7 m with resistivity values ranging from 200 to 400 Ω·m. This kind of multidisciplinary approach resulted to be suitable to study this type of archaeological sites, revealing that areas characterized by a relevant thickness and wide areal extension of volcanic lithotypes can be a potential site where Etruscans might have excavated their necropolis.</p>


2016 ◽  
pp. 25-29
Author(s):  
G. E. Stroyanetskaya

The problems of collectors at the stage of calculating the reserves in operating incline directional wells, penetrated on clay, polymer-clay solution, polymer washing liquid with hydrochloric-calcium foundation were considered. The electrical resistivity of the solution and the washing liquid from 0.1 to 1 O·mm. According to geophysical methods, establishing of the criteria for the allocation of the collectors requires coring. The main methods for the isolation of collectors are lateral, microlaterolog survey and caliper measurement. The techniques of the gas-saturated collectors porosity coefficient determination were considered.


2015 ◽  
Vol 2 (2) ◽  
pp. 955-994
Author(s):  
D. Michot ◽  
Z. Thomas ◽  
I. Adam

Abstract. Root uptake is the most decisive key in water transfer involving soil and vegetation. It depends on water availability which can be evaluated by punctual measurements. Additionally, surface geophysical methods such as Electrical Resistivity Tomography (ERT) provide larger spatial scales. This paper focuses on investigating temporal and spatial soil moisture changes, along a toposequence crossed by a hedgerow, using ERT and punctual measurements. 10 ERT were performed over the studied period for a 28 m long transect and compared to matric potential and groundwater level measurements. Soil Volumetric Water Content (VWC) was predicted using two methods (i) from ER using Waxman and Smits model (ii) and from matric potential using experimental retention curve fitted by Van Genuchten model. Probability Density Functions (Pdfs) of our set of data show that the largest change, in mean values of ER as well as matric potential, was observed in the topsoil layer. We then analyzed the consistency between ER and punctual measurements in this layer by extracting the arrays in the junction between ER grids and punctual measurements. Pdfs of ER maps at each monitoring time (from T01 to T10) were also calculated to select the more contrasted distributions corresponding to the wettest (T06) and driest states (T10). Results of ER were consistent with matric potential measurements with two different behaviors for locations inside and outside the root zone. A strong correlation (r = 0.9) between VWC values from Waxman and Smits model and those obtained from retention curve was observed outside the root zone. The heterogeneous soil system inside the root zone shows a different pattern in this relationship. The shift in the relationship between ER and soil moisture for the locations outside and inside the root zone highlights the non-stationarity in heterogeneous soil system. Such systems were actually related to the high hedgerow root density and also to a particular topographical context (ditch and bank) which is encountered in Brittany and over north-west of Europe.


Author(s):  
Łukasz Zawadzki ◽  
Dorota Wychowaniak ◽  
Mariusz Lech

Abstract Every single investment affects the natural environment, and that is why it is so important to eliminate nuisance it could cause. Extremely harmful effect on environment or human health could be expected from waste treatment facilities. One of the kinds of contamination which is a real threat to soil and water environment are leachates from landfills. They contain random chemical composition and can migrate from landfill through soil water flux leading to environmental pollution and degradation of groundwater. This paper focuses on the use of geophysical methods to assess migration of pollutants from the landfill through the subsoil. The laboratory tests of solute transport have been conducted on three soil samples from Łubna site to simulate the contamination flow. Migration of leachates through soil samples was controlled using the column test and electrical resistivity measurements which allow to com pare the results obtained with the standard column test method and electrical resistivity measurements. It leads to the conclusion that electrical resistivity methods for contamination transport monitoring in soil–water systems are suitable. Furthermore, field electrical resistivity tomography have been used for monitoring of the vertical sealing system in Łubna landfill.


Proceedings ◽  
2018 ◽  
Vol 2 (11) ◽  
pp. 664 ◽  
Author(s):  
David Zumr ◽  
Václav David ◽  
Josef Krása ◽  
Jiří Nedvěd

Small earth dams usually lack the detailed seepage monitoring system that would provide high resolution data on changes in seepage flow. Alternative solution is monitoring of the temperature and electrical resistivity in the body of the dams. Geophysical methods are useful techniques for a non-destructive exploration of the subsurface. We have utilized the combination of electrical resistivity tomography (ERT), ground penetrating radar (GPR) and multi-depth electromagnetical conductivity meter (CMD) techniques to observe the inner structure, especially internal failures, of the historical earth-filled dams. Longitudinal and transversal profiles of four typical fishpond dams in the Czech Republic were measured within this research. The dams were constructed as early as in the 15th century, some of them went through minor reconstruction. The aim of the application of geophysical methods for investigation of old fishpond dams was to detect and localize the boundary of the dam foundation, new earth material from the reconstruction works, cone of water depression, technical objects location, potential internal erosion, cavities, inhomogeneity in the water content pattern and any other anomalies. The primary results show that the ERT is suitable to observe the dam stratification, dam foundation, bedrock below the dam and large anomalies. GPR is suitable for small objects and anomalies detection in the shallow depths.


2017 ◽  
Vol 9 (1) ◽  
Author(s):  
Amin Amini ◽  
Hamidreza Ramazi

AbstractThis paper is devoted to the application of the Combined Resistivity Sounding and Profiling electrode configuration (CRSP) to detect underground cavities. Electrical resistivity surveying is among the most favorite geophysical methods due to its nondestructive and economical properties in a wide range of geosciences. Several types of the electrode arrays are applied to detect different certain objectives. In one hand, the electrode array plays an important role in determination of output resolution and depth of investigations in all resistivity surveys. On the other hand, they have their own merits and demerits in terms of depth of investigations, signal strength, and sensitivity to resistivity variations. In this article several synthetic models, simulating different conditions of cavity occurrence, were used to examine the responses of some conventional electrode arrays and also CRSP array. The results showed that CRSP electrode configuration can detect the desired objectives with a higher resolution rather than some other types of arrays. Also a field case study was discussed in which electrical resistivity approach was conducted in Abshenasan expressway (Tehran, Iran) U-turn bridge site for detecting potential cavities and/or filling loose materials. The results led to detect an aqueduct tunnel passing beneath the study area.


Sign in / Sign up

Export Citation Format

Share Document