scholarly journals Physicochemical Analysis of Water Quality of Brook Kuruçay

Author(s):  
Ekrem Mutlu ◽  
Arzu Aydın Uncumusaoğlu

In this study, through the analyses of water samples taken from 9 stations on the brook between July 2012 and June 2013, we aimed to determine the monthly and seasonal changes in water quality parameters of Brook Kuruçay, to determine the water quality properties, to reveal the pollution problems, to determine the suitability level in terms of aquatic life and to classify the quality of water in accordance with Surface Water Quality Management Regulation’s Inland Surface Water Classes criteria. The study area is located southeast of the Hafik District of Sivas city and the altitude is 2608 m. The water samples were collected from 9 stations established on the brook, and some physicochemical parameters and heavy metal concentrations were analyzed in water samples. The cleaning and maintenance of all of the equipment, land-type measurement tools, and glass sampling containers to be used in sampling were made 1 day before sampling. Sampling tubes were immersed into 15 cm below the water surface for taking water samples. Heavy metal concentrations were determined in the Sivas Provincial Control Laboratory in the same day with sampling (within 5 hours). The total alkalinity, total hardness, ammonium nitrogen, nitrite, nitrate, ammonium azote, phosphate, sulfite, sulfate, chloride, sodium, potassium, suspended solid matter (SSM), chemical oxygen demand (COD), biological oxygen demand (BOD), calcium, magnesium, ferrous, lead, copper, zinc, nickel, mercury and cadmium analyses of water samples were performed. As a result of the analyses, it was determined that, since Brook Kuruçay falls into the water resource class, which is the most sensitive to pollution, the water quality of the brook should be monitored regularly.

2008 ◽  
Vol 5 (3) ◽  
pp. 435-446 ◽  
Author(s):  
Mayur C. Shah ◽  
Prateek G. Shilpkar ◽  
Pradip B. Acharya

Present communication deals with study of physico-chemical parameters such as pH, electrical conductivity (EC), total dissolved solids (TDS), total alkalinity (TA), calcium hardness (CaH), magnesium hardness (MgH), total hardness (TH), chloride (Cl-), fluoride (F-), sodium (Na+), potassium (K+), dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD) and sulphate (SO42-) of water samples of bore wells of forty villages of Gandhinagar taluka of Gujarat state,India. The experimental values of water samples were compared with standard values given by World Health Organization (WHO) and United State Salinity Laboratory for drinking and irrigation purposes respectively. Water Quality Index (WQI) was also calculated to know the over all quality of water samples. The statistical analysis like mean, standard deviation (SD), coefficient of variance (% CV), analysis of variance (ANOVA),t-test, coefficient of correlation (r) and regression analysis of obtained data were carried out. The results show that the quality of water is poor and quite good for drinking and irrigation purposes respectively. The variance was found significant at 1% level of significance in case of sodium and potassium content and at 5% in case of total alkalinity and dissolved oxygen among the four regions (North, South, East and West) of Gandhinagar taluka. The linear relation also established for each pair of water quality parameters of studied water samples.


2021 ◽  
Vol 2114 (1) ◽  
pp. 012050
Author(s):  
Mohammad Yahya R Al-Yasiri ◽  
Hadi Dwaich Z. Al-Attabi

Abstract The quality of drinking water is related to the state of the water supply networks, pollution, and contamination of drinking water with contaminants of both anthropogenic and natural origin. Water samples were collected from 22 different waterworks in Kut, Iraq, and heavy metal concentrations (Pb, Ni, and Zn) were analyzed. In various parts of the city, 22 sampling sites were pre-defined. The results indicated that heavy metal concentrations in water samples did not surpass WHO guidelines (World Health Organization).


2017 ◽  
Vol 4 (4) ◽  
pp. 475-482 ◽  
Author(s):  
H. R. Bharathi ◽  
S. Manjappa ◽  
T. Suresh ◽  
B. Suresh

Present communication deals with a study of Physico-chemical parameters such as pH, Temperature, Total Suspended Solids, Turbidity, Dissolved Oxygen, Biochemical Oxygen Demand, Nitrate and Phosphate in water samples of Channarayapatna, Janivara, Anekere and Baghur water bodies in Channarayapatna taluka, Karnataka state of India. The water quality of the samples was compared with standard values given by World Health Organization (WHO) and United State Salinity Laboratory for drinking and irrigation purposes. Water Quality Index (WQI) was also calculated to know the overall quality of water samples. Water quality index (WQI) of Surface water body of various Sampling locations of Channarayapatna taluka, Karnataka ranged between 61.82 and 68.27 indicates the fair quality of water. The water quality index is calculated by indicator (100-point scale) shows that water is suitable for drinking purposes only after pretreatment like filtering, boiling, reverse osmosis and electro dialysis. WQI can play a big role in justifying the water pollution problems after encountered in different surface water bodies. Application of Water Quality Index (WQI) in this study has been found useful in assessing the overall quality of water and to get rid of judgment on quality of the surface water.Int J Appl Sci Biotechnol, Vol 4(4): 475-482


2017 ◽  
pp. 390-399
Author(s):  
Jigna Desai Desai ◽  
S.K. Tank

Water quality monitoring is an important aspect of water management concerning to the pollution control. Present communication deals with study of physico-chemical parameters such as pH, temperature , total dissolved solids (TDS),total suspended solids (TSS), total alkalinity (TA), , total hardness (TH), chloride (Cl), fluoride (F), sodium (Na), calcium (Ca), magnesium (Mg), sulphate (SO4), nitrate(NO3), nitrite (NO2), dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD) and heavy metals like chromium (Cr), arsenic (As), lead (Pb) and cadmium (Cd) of water samples from five sampling sites of River Tapti, Surat, Gujarat state, India. The water samples were collected at regular interval of 30 days for two consecutive years 2008-2009. The experimental values of water samples were compared with standard values given by World Health Organization (WHO). Water Quality Index (WQI) was also calculated to know the overall quality of water samples by using Water Rating System adapted by Canadian Council for Minister of the Environment (CCME-WQI). The data were analyzed statistically to identify those parameters which are responsible for variation in Water Quality Index (WQI). To identify those parameters we have done correlation analysis, testing of hypothesis, factor analysis and regression Analysis by using SPSS (Statistical Package for Social Science). The results show that the quality of water is poor and not good for drinking or irrigation purpose. The variance was found significant at 1% level of significance in case of and turbidity, BOD, Cr and Pb. It was found significant at 5% level in case of COD.


2021 ◽  
Vol 11 (9) ◽  
Author(s):  
Bishnu Prasad Sahoo ◽  
Himanshu Bhushan Sahu ◽  
Dhruti Sundar Pradhan

AbstractCoal mining and ancillary activities have the potential to cause water pollution characterized by acid mine drainage, acid mine leachates, extreme pH conditions and heavy metal contaminations. In the present work, 33 water samples in premonsoon and 34 water samples in monsoon were collected from the surface water bodies of Ib Valley coalfield, India for hydrogeochemical analysis. In premonsoon, pH, TSS, Turbidity, DO, BOD, COD, Magnesium, Cadmium, Selenium, Nickel, Aluminum and in monsoon, pH, TSS, Turbidity, DO, BOD, COD, Iron, Cadmium, Selenium, Nickel and Aluminum were nonconforming to the permissible limit set by the Bureau of Indian Standards, World Health Organisation and Ministry of Environment, Forest and Climate Change, Government of India. The average BOD/COD ratio of less than 0.6 in both seasons indicated Ib valley coalfield water was not fairly biodegradable. The analysis of variance (ANOVA) revealed that significant seasonal variation (p < 0.05) was observed in the hydro-chemical parameters viz. TSS, turbidity, redox potential, acidity, total hardness, bicarbonate alkalinity, chloride, sulfate, nitrate, sodium, calcium, magnesium, iron, cadmium, chromium and magnesium during the entire sampling period. Whereas, no significant seasonal variation (p > 0.05) was observed in pH, EC, TDS, DO, BOD, residual chlorine, COD, oil and grease, fluoride, potassium, zinc, copper, selenium, nickel, aluminum, boron, silica, temperature, salinity, cyanide and phenol. Water Quality Index revealed that 39.39% and 35.29% samples belong to poor water quality category in premonsoon and monsoon, respectively. As per Heavy Metal Pollution Index, Degree of Contamination (Cd) and Heavy metal evaluation index, medium degree of pollution were exhibited by 51.52%, 30.30% and 45.45% samples in premonsoon and 20.59%, 35.29% and 26.47% samples in monsoon. Whereas, 5.88%, 2.94% and 5.88% samples were having high degree of pollution in monsoon and 15.15% samples caused high degree of pollution with respect to Cd in premonsoon. However, EC, Na%, PI, SAR and RSC values suggested that the water can be used for irrigation. Water type of the region had been found to be Ca–Mg–Cl–SO4 by Piper diagram.


2020 ◽  
Vol 51 (5) ◽  
pp. 2041-2051
Author(s):  
Anthony Yaw Karikari ◽  
Ruby Asmah ◽  
William Wilson Anku ◽  
Steve Amisah ◽  
Nelson Wheatson Agbo ◽  
...  

2020 ◽  
Vol 16 (3) ◽  
pp. 178
Author(s):  
Arniza Fitri ◽  
Khairul Nizam Abdul Maulud ◽  
Dian Pratiwi ◽  
Arlina Phelia ◽  
Farli Rossi ◽  
...  

The issues of freshwater pollutions and the high demand of clean freshwater for daily human activities have forced developing countries such as Malaysia to continuously monitor the quality of the freshwater. The present study objective is to present the trend of water quality status in the Kelantan River downstream, Peninsular Malaysia from 2005 to 2018. Water samples were collected during dry and monsoon seasons from a sampling station located at downstream of the Kelantan River. Water quality parameters such as temperature, pH and dissolved oxygen (DO) were measured in situ while other parameters were analysed in the laboratory based on retrieved water samples. Water quality status was determined based on National Water Quality Standard (NWQS) for River in Malaysia by calculating the water quality index (WQI) according to the concentration of six water quality parameters involving pH, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (TSS) and Ammonia Nitrogen (AN). The results showed that Kelantan River had good water quality during the dry season classified in Class II at 2005. The water quality was found to be slightly lower during the monsoon season in year 2006. In addition, increasing the number of construction, human activities in the land use areas, land use changes and the sewage water from domestic, industrial, wet market and food outlets in the Kelantan State have declined the water quality in Kelantan River from Class II (in 2005) to Class III (in 2010 and 2011) and to become Class IV in 2017 to 2018. The results of the present study are expected to give valuable information for the water managers in order to deal with better strategies in controlling the quality of freshwater at the Kelantan River and minimize the incidence of pollution-oriented problems, thus the water can be utilized for various water uses with appropriate quality.


Sign in / Sign up

Export Citation Format

Share Document