scholarly journals Analytical Method Development and Validation for the Estimation of Canagliflozin in Bulk and Formulation by RP- HPLC

Author(s):  
Darshan Bhatt ◽  
Padmini Thatavarthi ◽  
B. Rajkamal

A simple and sensitive reverse phase high performance liquid chromatographic method was developed and successively validated for the estimation of Canagliflozin. In the new method, Canagliflozin separation was carried out by the nonpolar inertsil ODS-3 (250 × 4.6 mm, 5μ) column with a mobile phase composition of Ammonium acetate buffer (pH-4.5) and Acetonitrile in the ratio of 30:70% v/v. Canagliflozin was determined at 252 nm using UV detection and the compound was eluted at the retention time of 4.5 min. As per International Conference on Harmonization (ICH) guidelines, the method was validated and the parameters were precision, accuracy, linearity, limit of detection, limit of quantitation and robustness. The chromatographic method was accurate, linear, specific, precise and robust. The results of method concluded that the proposed RP-HPLC method is useful, convenient and reliable in regular analysis of Canagliflozin in bulk and its formulation

2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


2018 ◽  
Vol 8 (6-s) ◽  
pp. 78-82 ◽  
Author(s):  
Vishal Singh Solanki ◽  
RAM SINGH BISHNOI ◽  
Raviraj Baghel ◽  
Deepti Jain

A simple precise and economical reverse phase high performance liquid chromatographic method has been developed and validated for the simultaneous estimation of Cilnidipine (CDP), Atenolol (ATL) and Chlorthalidone (CTD).The chromatographic separation was achieved by using Hypersil- keystone C18 (4.6 x 250mm, 5μm) under isocratic conditions The mobile phase consisted of methanol and triple distilled water (80/20, v/v) having pH 7 with a flow rate of 1.0 mL/min. The eluents were monitored at 225 nm for simultaneous measurement.The selected chromatographic conditions were found to effectively separate CDP (Rt: 3.25 min), ATL (Rt: 5.366 min) and CTD (Rt: 9.025 min) having good resolution. The developed method was validated for linearity, accuracy, precision, LOD, LOQ, robustness and for system suitability parameters as per ICH guidelines. In this study, an excellent linearity was obtained with r2 = 0.999, r² = 0.999, r² = 1, for CDP, ATL and CTD respectively. The developed chromatographic method proved to be simple, precise, accurate, robust and reproducible Thus, this method would be employed for routine simultaneous quantification of CDP, ATL and CTD in bulk form or tablet dosage form.   Keywords: Cilnidipine, Atenolol and Chlorthalidone, RP-HPLC.


2019 ◽  
Vol 11 (1) ◽  
pp. 216 ◽  
Author(s):  
Ramya Kuber B.

Objective: To develop a simple, sensitive, specific, accurate reverse phase high performance liquid chromatographic (RP-HPLC) method for the estimation of curcumin and piperine.Methods: The separation was done using a column Inertsil–ODS C18 (250 mm × 4.6 mm, 5µ particle size) and mobile phase composed of methanol: water (45:55 v/v), flow rate at 1 ml/min and detection was carried out at 282 nm with photodiode array (PDA) detector.Results: The separation of curcumin and piperine were found to be at the retention time of 2.433 min and 3.095 min, respectively. The method was found to be linear at a concentration range 20-80 µg/ml for curcumin and piperine. The limit of detection (LOD) and limit of quantification (LOQ) was found to be 0.05µg/ml and 0.17µg/ml for curcumin and 0.18µg/ml and 0.53µg/ml for piperine respectively. The average percentage recoveries of curcumin and piperine were in the range of 98-100.6%.Conclusion: A simple and sensitive reverse phase high performance liquid chromatographic method was developed for the estimation of curcumin and piperine.


Author(s):  
Bhupender Tomar ◽  
Ankita Sharma ◽  
Inder Kumar ◽  
Sandeep Jain ◽  
Pallavi Ahirrao

A simple, precise, and accurate reverse phase high performance liquid chromatographic method (RP-HPLC) was developed and validated for the estimation of the combination of 5- Fluorouracil (5-FU) and Imiquimod in active pharmaceutical ingredients (APIs). The method was carried out on Phenomenex C18 (250 × 4.6mm I.D., 5𝜇m) using isocratic elution mode. The mobile phase was used as Acetonitrile: 10mM potassium dihydrogen orthophosphate: triethylamine (40:59.9:0.1, v/v, pH 4.5 with orthophosphoric acid) and Water: ACN (50:50 v/v) was used as a diluent. The concentration of solvents was 1-20µg/ml and the volume of injection was 20µl with the flow rate of 1.2ml/min. The retention times for 5-FU and Imiquimod were found to be 1.9±0.5 and 6.6±0.5 min respectively. The absorption maxima of 5FU and Imiquimod were found 267nm and 227nm respectively. The method was validated as per ICH guidelines. All the data were found within the specified limits. The limit of detection (LOD) and limit of quantification (LOQ) of 5- Fluorouracil were found to be 0.015μg/mL and 0.048 μg/mL, respectively, and Imiquimod was found to be 0.078μg/mL and 0.237μg/mL, respectively. The method developed in the present study was found to be sensitive, specific, and precise and can be applied for the simultaneous estimation of 5-FU and Imiquimod.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (08) ◽  
pp. 12-16
Author(s):  
S Vidyadhara ◽  
◽  
L. S Reddyvalam ◽  
T. Koduri ◽  
P. K. Borra ◽  
...  

A simple, accurate, precise high-performance liquid chromatographic (HPLC) method has been developed and validated for the simultaneous determination of abacavir sulphate (ABA) and lamivudine (LAM) in combined dosage form. Separation was performed on a C18 column [Agilent ODS UG 5 column, 250 mm x 4.5 mm], with methanol: water (50:50 V/V) isocratic elution using a flow rate of 1mL/min. Good sensitivity was observed with UV detection at 277 nm. After method development, the interference of other active compounds and excipients, repeatability and linearity, were investigated. Retention times of LAM and ABA were found to be 3.3 and 6.3 min, respectively. The method was validated over the range from 2.5-12.5 μg/mL for LAM and 5-25 μg/mL for ABA with correlation coefficients of 0.9997 and 0.9996, respectively. This method was shown to be accurate, robust, selective, linear, and repeatable and can be successfully employed in routine quality control for the simultaneous analysis of ABA and LAM in tablets.


Author(s):  
Zubaidur Rahman ◽  
Vijey Aanandhi M ◽  
Sumithra M

Objective: A simple, novel, sensitive, rapid high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for quantitative determination of atomoxetine HCl (ATH) in bulk and formulations.Methods: The chromatographic development was carried out on RP-HPLC. The column used as Xterra RP 18 (250 mm × 4.6 mm, 5 μ particle size), with mobile phase consisting of methanol: water 80:20 V/V. The flow rate was 1.0 mL/min and the effluents were monitored at 270 nm.Results: The retention time was found to be 5.350 min. The method was validated as per International Conference on Harmonization Guideline with respect to linearity, accuracy, precision, and robustness. The calibration curve was found to be linear over a range of 2–10 μg/mL with a regression coefficient of 0.9999. The method has proved high sensitivity and specificity.Conclusion: The results of the study showed that the proposed RP-HPLC method was simple, rapid, precise and accurate which is useful for the routine determination of ATH in bulk drug and in its pharmaceutical dosage form.


2017 ◽  
Vol 9 (6) ◽  
pp. 34
Author(s):  
Madhavi K. ◽  
Navamani M. ◽  
Prasanthi C.

Objective: To develop a simple, rapid, economic, accurate and precise reverse phase-high performance liquid chromatographic (RP-HPLC) method for the determination of hydrochlorothiazide and candesartan in the pharmaceutical dosage form and to validate as per international conference on harmonization (ICH) guidelines.Methods: The chromatographic separation was performed on Silanol BDS C18 column (250 x 4.6 mm, 5 μm), a mobile phase consisting of water (pH adjusted to 2.8 with orthophosphoric acid): acetonitrile (30:70 % v/v), with a flow rate 1 ml/min and the detection wavelength of 210 nm using photodiode array (PDA) detector.Results: The developed method resulted in elution of hydrochlorothiazide at 2.28 min and candesartan at 4.28 min. The calibration curves were linear (r2=0.999) in the concentration range of 6.25-18.75 μg/ml and 8-24 μg/ml for hydrochlorothiazide and candesartan respectively. The percentage recoveries were found to be 99.78-100.39 for hydrochlorothiazide and 99.87-100.64 for candesartan. The limit of detection (LOD) was found to be 0.410 μg/ml and 0.699 μg/ml for hydrochlorothiazide and candesartan respectively. The limit of quantitation (LOQ) was found to be 1.367 μg/ml and 2.330 μg/ml for hydrochlorothiazide and candesartan respectively.Conclusion: A simple, economic, accurate, precise, linear and rapid RP-HPLC method was developed for simultaneous quantitative estimation of hydrochlorothiazide and candesartan in bulk and pharmaceutical formulation and the method was validated as per ICH guidelines. Hence, the method holds good for the routine analysis of hydrochlorothiazide and candesartan in various pharmaceutical industries as well as in academics.


Author(s):  
Sunkara Namratha ◽  
Vijayalakshmi A

Objective: Reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the assessment of lopinavir in the dosage form of tablet.Methods: Chromatogram was run through using Kromosil C18 4.5×150 mm using a mobile phase methanol: water of ratio 65:35% v/v with a rate of flow of 0.8 ml/min, measured by UV spectrometric detection at 265 nm. The method developed was validated in terms of precision, accuracy, linearity, and robustness parameters.Results: Retention time of lopinavir established at 2.482 min and percentage R.S.D of lopinavir found to be 1.0% and 0.5%, respectively. The method shows that good linearity range of 30–150 μg correlation coefficient of lopinavir was 0.997. The limit of detection was 2.97 and limit of quantification was 9.92, respectively. The percent purity of lopinavir was 99.87%.Conclusion: The suggested method (Rp-HPLC) for concurrent assay lopinavir was validated, which is appropriate method for the analysis oflopinavir quantitatively in tablet dosage forms and bulk.