Prediction of Heat-Generation and Electromagnetic Parameters from Temperature Response in Porous Fins

Author(s):  
Ranjan Das ◽  
Balaram Kundu
Author(s):  
Jun Yu ◽  
Zhen’an Tang ◽  
Zhengxing Huang ◽  
Chong Feng

Previous studies of bridge-based micro calorimeters have shown that these devices can measure heat capacity and melting point of ultra thin films with pulse scan calorimetry. The bridge-based micro calorimeters consist of a sample region and several beams that connecting the sample region with silicon substrate. Both the sample region and the beams are suspending on the silicon substrate for thermal isolation. The temperature distribution of the micro calorimeter during a heating pulse depends on the joule-heating of the heating resistor, the heat absorption and heat conduct of the bridge. The heat transfer through the beams during a pulse scan measurement is complex because there is heat generation on some beams and the temperature distribution along the beams is not uniform. Using three dimensional finite element analyses (FEA), the thermal-electrical simulations of the heat transfer in the bridge-based micro calorimeters have been performed. The heat consumption and temperature distribution at steady state analyses, the temperature response of the bridge and the heat generation of the heater at transient analyses have been calculated for the bridge-based micro calorimeter with different sample thermal conductivities and heat capacities. The simulation results indicate that for the bridge-based microcalorimeter using pulse calorimetry, when the heat capacity of the sample film is close to or larger than the heat capacity of an empty calorimeter, the differential method of getting the sample heat capacity from the difference between a micro calorimeter with and without the sample is no longer suitable because the heat transfer and temperature distributions of the two calorimeters are no longer comparable to each other.


2010 ◽  
Vol 4 (6) ◽  
pp. 885-892 ◽  
Author(s):  
Wiroj Limtrakarn ◽  
Somporn Reepolmaha ◽  
Pramote Dechaumphai

Abstract Background: During cataract operation (phacoemulsification), a phaco needle-tip is inserted into the anterior chamber of eye. Then, heat is generated by the oscillation of the phaco needle, which may injury the corneal endothelial cells. There are no data available for temperature responses at the corneal endothelium to heat from the phaco needle during phacoemulsification. Objective: Investigate temperature distribution on the corneal endothelium during ophthalmic phacoemulsification using numerical simulation, and compare the transient temperature response to heat between balanced salt solution (BSS) and ophthalmic viscoelastic device (OVD), Viscoat®. Methods: Heat flux from a phaco needle was measured with thermal properties of BSS and AVS in an experimental setting. Then, nodeless variable finite element method was applied to predict temperature changes in the eye by the phaco needle inserted into the anterior chamber. The transient temperature distribution on the corneal endothelium was calculated at 10, 20, and 30 seconds after heat generation by the needle. Results: The heat generation of phaco needle without sleeve cover was 1.6 kW/m2. The numerical simulation showed that the maximum temperature occurs on the wound location at all times after heat generation by the phaco needle. Especially, at time 30 seconds, it was 49.2 and 41.7°C in BSS and OVD, respectively. The temperature elevation by the phaco needle was lower in OVD than BSS. Conclusion: Phacoemulsification is a heat-generating procedure performed between the anterior chamber structures of eye. During this procedure, OVD may protect the corneal endothelium against heat better than BSS.


Author(s):  
Claude Jaupart ◽  
Jean-Claude Mareschal
Keyword(s):  

1984 ◽  
Vol 45 (C1) ◽  
pp. C1-909-C1-914 ◽  
Author(s):  
I. Montanari ◽  
F. Negrini