scholarly journals Reliability, Sensitivity to Change, and Responsiveness of the Peabody Developmental Motor Scales–Second Edition for Children With Cerebral Palsy

2006 ◽  
Vol 86 (10) ◽  
pp. 1351-1359 ◽  
Author(s):  
Hsiang-Hui Wang ◽  
Hua-Fang Liao ◽  
Ching-Lin Hsieh

Abstract Background and Purpose. The psychometric properties of the Peabody Developmental Motor Scales–Second Edition (PDMS-2), a revised motor test to assess both gross motor and fine motor composites in children with cerebral palsy (CP), are largely unknown. The purpose of this study was to examine the test-retest reliability and the responsiveness of the PDMS-2 for children with CP. Subjects. A sample of 32 children who had CP (age=27–64 months) and who received intervention participated in this study. Methods. The PDMS-2 was administered to each child 3 times (at the beginning of the study, at 1 week, and at 3 months later) by a physical therapist. The agreement between the first 2 measurements was used to examine the reliability. The change between the first and the third measurements was used to examine the responsiveness. Results. The composite scores on the PDMS-2 had good test-retest reliability (intraclass correlation coefficient=.88–1.00). The sensitivity-to-change coefficients ranged from 1.6 to 2.1, and the responsiveness coefficients ranged from 1.7 to 2.3. Discussion and Conclusion. Our results provide strong evidence that the 3 composites of the PDMS-2 had high test-retest reliability and acceptable responsiveness. The PDMS-2 can be used as an evaluative motor measure for children with CP and aged 2 to 5 years.

Author(s):  
Do Hyun Kim

PURPOSE: We explored the test-retest reliability of pelvic rotation measured using a smartphone and established criterion-related validity by analyzing simple linear regression between pelvic rotation data obtained using the smartphone and those measured by a palpation meter. METHODS: We recruited 12 children with cerebral palsy (CP) (7 boys and 5 girls) and measured pelvic rotation using a smartphone application and a palpation meter in the sitting, standing, and one-leg standing positions. Test-retest reliability was evaluated by calculating intraclass correlation coefficients (ICCs); simple linear regression was analyzed to explore the relationships between smartphone and palpation meter data. RESULTS: In terms of the test-retest reliability of pelvic rotation measured by the smartphone, the ICCs ranged from 0.85 to 0.95. A positive linear correlation was found between smartphone and palpation meter data. CONCLUSIONS: We confirmed that measurement of pelvic rotation using a smartphone was reliable when children with CP were in the sitting, standing, and one-leg standing positions. In addition, pelvic rotation measured using the smartphone correlated significantly with that measured using a palpation meter.


2021 ◽  
pp. 003151252110497
Author(s):  
Marco Tofani ◽  
Giulia Blasetti ◽  
Luca Lucibello ◽  
Anna Berardi ◽  
Giovanni Galeoto ◽  
...  

Limitations in hand function are common among children with cerebral palsy (CP), with almost 50% presenting an arm–hand dysfunction. However, there is no standardized assessment tool available in Italian for evaluating bimanual performance for this population. Our objective in this study was to evaluate the psychometric properties of an Italian translation of the ABILHAND-Kids (ABILHAND-Kids-IT) among children with CP. We examined internal consistency using Cronbach’s Alpha and Omega coefficients, and we investigated test-retest reliability with intraclass correlation coefficients (ICC). We performed explorative factor analysis (EFA) to investigate structural validity. We calculated Pearson’s correlation coefficients between the ABILAND-Kids IT and the Manual Ability Classification System (MACS) to assess criterion validity; and, to demonstrate the score variability of the ABILHAND-Kids-IT, we used analyses of variance (ANOVAs) to compare the 181 children with CP in this sample with their levels on the MACS. We enrolled 181 children with CP in the study. EFA confirmed a uni-dimensional scale. We obtained internal consistency on both Cronbach’s Alpha and Omega coefficient of 0.98, and a one-week test-retest reliability analysis revealed an ICC with 95% of confidence interval of .992. The ANOVA revealed significant score variability ( p < 0.01) and the Pearson correlation coefficient comparing the ABILHAND-Kids-It score with the MACS was –0.929 ( p < 0.01). We conclude that the ABILHAND-Kids-IT is valid and reliable for use with Italian children with CP.


2000 ◽  
Vol 80 (9) ◽  
pp. 873-885 ◽  
Author(s):  
Dianne J Russell ◽  
Lisa M Avery ◽  
Peter L Rosenbaum ◽  
Parminder S Raina ◽  
Stephen D Walter ◽  
...  

Abstract Background and Purpose. This study examined the reliability, validity, and responsiveness to change of measurements obtained with a 66-item version of the Gross Motor Function Measure (GMFM-66) developed using Rasch analysis. Subjects and Methods. The validity of measurements obtained with the GMFM-66 was assessed by examining the hierarchy of items and the GMFM-66 scores for different groups of children from a stratified random community-based sample of 537 children with cerebral palsy (CP). A subset of 228 children who had been reassessed at 12 months was used to test the hypothesis that children who are young (&lt;5 years of age) and have “mild” CP will demonstrate greater change in GMFM-66 scores than children who are older (≥5 years of age) and whose CP is more severe. Data from an additional 19 children with CP who were assessed twice, one week apart, were used to examine test-retest reliability. Results. The overall changes in GMFM-66 scores over 12 months and a time × severity × age interaction supported our hypotheses. Test-retest reliability was high (intraclass correlation coefficient=.99). Conclusion and Discussion. This study demonstrated that the GMFM-66 has good psychometric properties. By providing a hierarchical structure and interval scaling, the GMFM-66 can provide a better understanding of motor development for children with CP than the 88 item GMFM and can improve the scoring and interpretation of data obtained with the GMFM.


2012 ◽  
Vol 167 (3) ◽  
pp. 337-342 ◽  
Author(s):  
Alicia Santos ◽  
Eugenia Resmini ◽  
Ma Antonia Martínez-Momblán ◽  
Iris Crespo ◽  
Elena Valassi ◽  
...  

ObjectiveTo evaluate health-related quality of life (HRQoL) in Cushing's syndrome (CS) with the disease-generated CushingQoL questionnaire and to confirm its psychometric properties of test–retest reliability and sensitivity to change.DesignClinical practice conditions in a tertiary referral center.MethodsThe CushingQoL and EuroQoL questionnaires were administered at baseline and during follow-up and correlated with clinical parameters in 59 patients with CS. To check test–retest reliability, stable patients (either biochemically cured or with active hypercortisolism) were evaluated twice. To investigate sensitivity to change, new patients were evaluated at diagnosis and twice more following improvement after successful surgery.ResultsAt baseline, patients with active disease scored lower (indicating worse HRQoL) than those cured on the CushingQoL (46±14 vs 58±20, P<0.05) but not on the EuroQoL-visual analog scale (VAS; 64±20 vs 70±16, P NS). Test–retest reliability of CushingQoL was confirmed in stable patients, both in the ‘cured group’ (intraclass correlation coefficient (ICC)=0.78, n=34) and in the ‘active group’ (ICC=0.66, n=14). Sensitivity to change was confirmed in the ‘improvement group’ (n=11), as the CushingQoL score increased 4±1.5 and 9±3 months after surgery (P<0.01 and <0.001 respectively); the EuroQoL-VAS only improved after 9±3 months (P<0.01). Effect sizes were 1.02 and 1.86 for CushingQoL at 4±1.5 and 9±3 months respectively. Finally, scores of both questionnaires were correlated (r=0.504; P<0.001).ConclusionsThe CushingQoL questionnaire shows good test–retest reliability and sensitivity to change in clinical practice conditions.


2019 ◽  
Vol 26 (9) ◽  
pp. 1-11
Author(s):  
Azade Riyahi ◽  
Mehdi Rassafiani ◽  
Zahra Nobakht ◽  
Hosseinali Abdolrazaghi ◽  
Rahmatollah Moradzadeh

Background/Aims The ability to eat and drink is the most important factor in health, survival and longevity. Children with cerebral palsy can suffer from severe dysphagia, which can lead to a high risk of aspiration and choking. As classifying eating and drinking ability in children with cerebral palsy is important in research and treatment, the aim of this study was to determine the cross-cultural validation and reliability of the Persian version of the Eating and Drinking Ability Classification System. Methods After translation procedures, the face validity, content validity, test–retest reliability and interrater reliability of the Eating and Drinking Ability Classification System were evaluated. In total, 130 parents of children with cerebral palsy and 34 therapists participated in the evaluation of the scale's reliability. The 73 boys and 57 girls with cerebral palsy were aged 3–20 years (mean age 4.4 years) and had various types of cerebral palsy. They were classified according to the Eating and Drinking Ability Classification System by both their parents and the therapists. Results The overall results indicated that the words and sentences used were simple, clear, understandable, relevant and necessary. The intraclass correlation coefficients for test–retest reliability for parents, occupational therapists and speech therapists were 0.98, 0.98 and 0.995, respectively. The interrater reliability between parents and occupational therapists was 0.96, between parents and speech therapists was 0.95, and between occupational therapists and speech therapists was 0.985. Conclusions The Persian version of the Eating and Drinking Ability Classification System seems to be valid and reliable. This system may be used to evaluate children with cerebral palsy.


2020 ◽  
pp. 153944922096107
Author(s):  
Ecem Karanfil ◽  
Yeliz Salcı ◽  
Ayla Fil-Balkan ◽  
Can Ebru Bekircan-Kurt ◽  
Sevim Erdem Özdamar ◽  
...  

Linguistic, reliable, and valid secondary efficacy measures are important in clinical settings and studies. The aim of the study is to report test–retest reliability and construct validity of Turkish version of Myasthenia Gravis-Activities of Daily Living Scale (MG-ADL-T) in Myasthenia Gravis (MG) patients. Fifty-two ocular and generalized individuals with MG, applying to rehabilitation center, were included in the study. MG-ADL-T, MG quality-of-life questionnaire (MG-QoL), MG composite (MGC), quantitative MG score (QMGS), and pulmonary function test were administered. Reliability was assessed with intraclass correlation coefficient (ICC) and Cronbach’s alpha. Spearman correlation test and receiver operating characteristic (ROC) analysis were performed for construct validity. MG-ADL-T had fair internal consistency (Cronbach’s α = .67), excellent test–retest reliability (ICC = 0.96) and moderate construct validity (MG-QoL, r = 0.59; QMGS, r = .58; MGC, r = .68). MG-ADL, a unique scale that evaluates activities of daily living (ADL), has good test–retest reliability and construct validity in Turkish MG patients.


2006 ◽  
Vol 86 (8) ◽  
pp. 1107-1117 ◽  
Author(s):  
Olaf Verschuren ◽  
Tim Takken ◽  
Marjolijn Ketelaar ◽  
Jan Willem Gorter ◽  
Paul JM Helders

Abstract Background and Purpose. The purpose of this study was to examine the reliability and validity of data obtained with 2 newly developed shuttle run tests (SRT-I and SRT-II) to measure aerobic power in children with cerebral palsy (CP) who were classified at level I or II on the Gross Motor Function Classification System (GMFCS). The SRT-I was developed for children at GMFCS level I, and the SRT-II was developed for children at GMFCS level II. Subjects. Twenty-five children and adolescents with CP (10 female, 15 male; mean age=11.9 years, SD=2.9), classified at GMFCS level I (n=14) or level II (n=11), participated in the study. Methods. To assess test-retest reliability of data for the 10-m shuttle run tests, the subjects performed the same test within 2 weeks. To examine validity, the shuttle run tests were compared with a GMFCS level–based treadmill test designed to measure peak oxygen uptake. Results. Statistical analyses revealed test-retest reliability for exercise time (number of levels completed) (intraclass correlation coefficients of .97 for the SRT-I and .99 for the SRT-II) and reliability for peak heart rate attained during the final level (intraclass correlation coefficients of .87 for the SRT-I and .94 for the SRT-II). High correlations were found for the relationship between data for both shuttle run tests and data for the treadmill test (r=.96 for both). Discussion and Conclusion. The results suggest that both 10-m shuttle run tests yield reliable and valid data. Moreover, the shuttle run tests have advantages over a treadmill test for children with CP who are able to walk and run (GMFCS level I or II). [Verschuren O, Takken T, Ketelaar M, et al. Reliability and validity of data for 2 newly developed shuttle run tests in children with cerebral palsy. Phys Ther. 2006;86:1107–1117.]


Sports ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. 117
Author(s):  
Mike Climstein ◽  
Jessica L. Alder ◽  
Alyce M. Brooker ◽  
Elissa J. Cartwright ◽  
Kevin Kemp-Smith ◽  
...  

Background: Usage of wrist-worn activity monitors has rapidly increased in recent years, and these devices are being used by both fitness enthusiasts and in clinical populations. We, therefore, assessed the test–retest reliability of the Polar Vantage M (PVM) watch when measuring heart rate (HR) during various treadmill exercise intensities. Methods: HR was measured every 30 s (simultaneous electrocardiography (ECG) and PVM). Test–retest reliability was determined using an intraclass correlation coefficient (ICC) with 95% confidence intervals (CIs). Standard error of measurement (SEM) and smallest real difference (SRD) were used to determine measurement variability. Results: A total of 29 participants completed the trials. ICC values for PVM during stages 1, 2 and 5 demonstrated good to excellent test–retest reliability (0.78, 0.78 and 0.92; 95% CI (0.54–0.90, 0.54–0.9, 0.79–0.97)). For PVM during stages 0 (rest), 3 and 4, the ICC values indicated poor to good reliability (0.42, 0.68 and 0.58; 95% CI (−0.27–0.73, 0.32–0.85, 0.14–0.80)). Conclusion: This study identified that the test–retest reliability of the PVM was comparable at low and high exercise intensities; however, it revealed a poor to good test–retest reliability at moderate intensities. The PVM should not be used in a clinical setting where monitoring of an accurate HR is crucial to the patients’ safety.


Sign in / Sign up

Export Citation Format

Share Document