Analysis of Problem and Efficient Utilization Plan of Measurement Data in Sewage Treatment Equipment

2019 ◽  
Vol 20 (6) ◽  
pp. 437-444
Author(s):  
Kwang-Yong Ko
2018 ◽  
Vol 53 ◽  
pp. 04010
Author(s):  
Huang Jin ◽  
Wang Yueping ◽  
Zhang Xinheng ◽  
Chen Bin ◽  
Shi Ming ◽  
...  

This paper expounds the background and significance of the national standard of the development on the minimum allowable values of energy efficiency and energy efficiency grades for submersible pushing-flow agitator and rotary aerator in wastewater treatment, and introduces the general principle of the standard, the determination of the minimum allowable values of energy efficiency, the division of the energy efficiency grades for them, as well as the testing and calculation methods. It hopes to eliminate the production of the high energy consumption sewage treatment equipment, and enhance their level of the energy efficiency effectively through development and implementation of the national standard.


Author(s):  
M. Firdaus B. Basrawi ◽  
Takanobu Yamada ◽  
Kimio Nakanishi

Efficient utilization of biomass by a cogeneration system (CGS) is a promising technology for promoting sustainable energy development. Sewage treatment plants are facilities that have been continuously producing biogas by anaerobic digestion. Thus, the potential of a biogas-fuelled CGS in a sewage treatment plant is estimated to be very high. However, there have been few reports on the performance of a biogas-fuelled CGS, particularly regarding the effect of ambient temperature on its performance, and the most efficient arrangement of a biogas-fuelled CGS remains unknown. In this study, performance of a biogas-fuelled CGS was simulated under three typical ambient temperature (low, medium and high) conditions using actual data for a CGS with a micro gas turbine. In the beginning of this study, the relation of energy balance of the plant and ambient temperature was clarified. It was found that the amount of heat demand is ambient temperature-dependent but that the amount of biogas fuel produced is almost constant throughout the year. When a boiler is replaced with a biogas-fuelled CGS to utilize the biogas, under a high temperature condition, the CGS is not able to fully utilize all of the biogas produced, and therefore another pathway of biogas utilization is needed. Under a medium temperature condition, a gas storage system is needed for using biogas efficiently. However, some of the biogas still cannot be utilized efficiently. Under a low temperature condition, since ambient temperature varies greatly between summer and winter, the amount of heat demand of the plant also varies greatly throughout the year. This leads to an imbalance in biogas production and heat demand, and therefore attention must be given to energy management in this condition. The combination of other auxiliary equipment such as a boiler, heat pump and gas storage with the CGS is required in order to cover the total heat demand throughout the year. Four possible arrangements of the CGS with different auxiliary components were proposed and their performances were compared. It was found that all of the proposed CGS arrangements can sufficiently cover the total heat demand by only using biogas produced in the facility. Compared to the conventional system, all proposed CGS arrangements can reduce electrical power demand by 23∼28%, recover 74∼77% of the energy of biogas produced, and utilize almost 100% of the biogas produced. The arrangement with a heat pump is more efficient than the arrangement with a boiler. It was also found that excess biogas in summer can be used in winter by storing the biogas. Thus, a CGS arrangement that includes a gas storage system will enable efficient utilization of biogas and recovered exhaust heat.


2013 ◽  
Vol 838-841 ◽  
pp. 2561-2565
Author(s):  
Chun Jie Wang ◽  
Zhi Man Zhao ◽  
Xiao Mei Zhang

Choose an appropriate occasion for aeration equipment update, is an important problem faced by the wastewater treatment plant. This paper discussed the update of urban wastewater treatment equipment in the aeration equipment by economic life analysis methods, proposed a mathematical model and solving method of updating strategy,which is involved in a variety of cost factors and universal optimal,and is verified with examples.


Sign in / Sign up

Export Citation Format

Share Document