scholarly journals Quality control procedures applied to routine electron probe analyses of kimberlite indicator minerals

Author(s):  
Hua Younan

Abstract In wafer fabrication (Fab), Fluorine (F) based gases are used for Al bondpad opening process. Thus, even on a regular Al bondpad, there exists a low level of F contamination. However, the F level has to be controlled at a lower level. If the F level is higher than the control/spec limits, it could cause F-induced corrosion and Al-F defects, resulting in pad discoloration and NSOP problems. In our previous studies [1-5], the theories, characteristics, chemical and physical failure mechanisms and the root causes of the F-induced corrosion and Al-F defects on Al bondpads have been studied. In this paper, we further study F-induced corrosion and propose to establish an Auger monitoring system so as to monitor the F contamination level on Al bondpads in wafer fabrication. Auger monitoring frequency, sample preparation, wafer life, Auger analysis points, control/spec limits and OOC/OOS quality control procedures are also discussed.


Author(s):  
J. B. Allen ◽  
T. Deans

SummaryA detrital assemblage of magnesian ilmenite, pyrope, chrome-diopside, rutile, and zircon has been traced to outcropping ultrabasic alkaline rocks, hitherto unknown in the Melanesian region. Analyses and descriptions of these ‘kimberlite indicator minerals’ are given. The host rocks comprise alnöite, an alnöite breccia with calcite matrix, and a magnesian ankaratrite, which are described, with chemical analyses. Emphasis is laid on the abundance of ultrabasic inclusions and xenocrysts and the replacements and transformations they have undergone. Malaita Island promises to contribute significantly to the understanding of the relations between alnöite, melilite basalts, and kimberlites.


1974 ◽  
Vol 20 (4) ◽  
pp. 502-504 ◽  
Author(s):  
Daniel M Baer

Abstract Several technical difficulties diminish the usefulness of serum triglyceride estimation by the method of Stone and Thorp [Clin. Chim. Acta 14, 812 (1966)]. An artificial and somewhat unstable material is used in the standardization. Falsely elevated readings caused by scratched cuvettes are a frequent problem. Conventional quality-control procedures cannot be used because stable preparations are not available. Specimen stability is a greater problem than with conventional chemical methods. In spite of these difficulties, the method can be useful, if its limitations are recognized, in measurements made on nonfasting individuals.


2012 ◽  
Vol 500 ◽  
pp. 715-720
Author(s):  
Jian Guang Li ◽  
Jian Ding ◽  
Huai Jing Jing ◽  
Ying Xue Yao

Accuracy of the Stewart parallel manipulator is utmost important in assembly quality control procedures, and it's also difficult to demonstrate the inner relations quantitatively between errors of pose and of actuators. A novel methodology is proposed in this paper. Firstly the experiment area planning approach is proposed according to the pose and strut symmetries of the manipulator, and the uniform experiment design is conducted to investigate indexes of accuracy sensitivity. The regression equations are established to analyze the significance of various factors according to experiment results.


1986 ◽  
Vol 7 (3) ◽  
pp. 46-65 ◽  
Author(s):  
Pentti M. Rautaharju ◽  
Steven K. Broste ◽  
Ronald J. Prineas ◽  
William J. Eifler ◽  
Richard S. Crow ◽  
...  

2000 ◽  
Vol 113 (2) ◽  
pp. 240-248 ◽  
Author(s):  
Jay J. Ye ◽  
Stephen C. Ingels ◽  
Curtis A. Parvin

Sign in / Sign up

Export Citation Format

Share Document