scholarly journals Survey of Electric Field Intensity and Magnetic Density at High Voltage Substations (230 kV) in Golestan Province

2020 ◽  
Vol 7 (2) ◽  
pp. 111-118
Author(s):  
Mohamad Ranjbarian ◽  
◽  
Jaleledin Saadi ◽  
Korosh Etemad ◽  
Rozita Farhadi ◽  
...  
2013 ◽  
Vol 448-453 ◽  
pp. 328-331
Author(s):  
Xin Zhao ◽  
Tao Chen ◽  
Wei Wang ◽  
Yan Hong Huang Fu

The power frequency electric field and Electric radiation generated by high voltage transmission line have a great impact on the surrounding environment, which is one of the important research topic on environmental protection and electromagnetic compatibility technology field. In this paper, the information database of typical transmission line and tower established,and the prediction of power frequency electric field intensity of high voltage transmission line has been given by using the 3-D computational method.Then, the major factors affecting the calculation results of electric field is discussed based on the measured data and the error analysis is given.


2013 ◽  
Vol 291-294 ◽  
pp. 2428-2431
Author(s):  
Hui Lan Jiang ◽  
Kai Zeng ◽  
Jian Min Liu ◽  
Chao Li

In ultra-high voltage transmission system, the electrostatic induction generated by power frequency electric field will exerts negative effects on the electrical automation equipment within the substation and, in particular, will leads long-term harm to staffs’ health. However, researches of electric field environment in ultra-high voltage transmission system merely concentrate on calculating the electric field intensity caused by three-phase limited length wire or three-phase infinite wire within the transmission, without considering the method of calculating half-infinite wire which represents “one end is fixed, while the other end is infinite length’s wire”. Consequently, a new method named “Charge Simulation-Genetic Algorithm (CS-GA) method” which can efficiently calculate power frequency electric field inside of the substation is proposed in the paper. In CS-GA method, the effective calculating length is determined by genetic algorithm method’s optimization, which in other words, half-infinite length wire is substituted for limited length wire in calculating the electric field intensity. The simulation results indicate that CS-GA method is a relatively accurate, efficient and reasonable way on calculating the power frequency electric field inside of the substation.


2012 ◽  
Vol 441 ◽  
pp. 695-698
Author(s):  
Qing Wang ◽  
Jie Min ◽  
Jia Tian

Water treated by external electric field with different field intensity. The absorbency of water, the changes of dyes solubility, the effect of treatment time and the changes of wool swelling were studied. The results showed that electric field treatments can alter the water physical properties to various degrees. The absorbance of water increased with increasing electric field intensity. The swelling ratio indicated the ability of solvent to penetrate the wool fibers and to swell them.


2021 ◽  
Vol 3 (2) ◽  
Author(s):  
Yuzhe Liu ◽  
Lidong Lin ◽  
Han Dong

In this project, we investigated how ion thrusters produce propulsion and how the design of ion thrusters affects the performance of the thruster. In the experiment, we build a high voltage power supply (0- 50 kV) and foil rings to produce ion wind. When considering the design of the thruster, we focus on three variables: the volume of the space, where ions are produced and the electric field intensity. Thus, to investigate the first variable we made foil rings with different radius and change the distance between the ring and positive cathode. To determine the propulsion produced we use a speed sensor to determine the magnitude of the wind produced.


Author(s):  
Mihaela Frigura-Iliasa ◽  
Adrian F. Olariu ◽  
Felicia I. Baloi ◽  
Flaviu Mihai Frigura-Iliasa ◽  
Doru Vatau ◽  
...  

2017 ◽  
Vol 1 (2) ◽  
pp. 22
Author(s):  
Anak Agung Ngurah Amrita

Distribution of electrical energy from a plant to a substation or from a substation to other substations usually uses a transmission line. In Bali, type of transmission line that is usually implemented is SUTT 150 kV. The magnitude of the applied voltage is an attempt to reduce power loss for long distance distribution. However, distributing electrical energy with increasing stress affects the increase of electric field around the transmission line. The negative impact of electricity distribution has been an environmental problem for PT. PLN (Persero), especially where there is conversion from an open area to be a residential. This problem has been the main reason for conducting this research. IRPA / INIRC recommendation states that exposure time is not limited to the electric field effect in work environment and public area including a residential area at frequency of 50/60 Hz is 5 kV/m.  This recommendation is in accordance with SNI 04-6950-2003, on Threshold Limit Values ??Electric Field under SUTT and high-voltage wires. The first problem of this research is how large the intensity of the electric field between two poles of SUTT 150 kV with vertical and horizontal constructions which are built side by side? The second problem is what the characteristic of the electric field intensity between the two poles which are built side by side? From the analysis, it can be seen that the intensity of the electric field that occurs between the conductor of the vertical and horizontal pole configurations are still below the IRPA/INIRC and SNI 04-6950-2003 recommendation i.e. 1 up to 1.5 kV/m and at a distance of 18 meters to 25 meters there is an interaction of electric field intensity that occurs at these two configurations.


Sign in / Sign up

Export Citation Format

Share Document