scholarly journals Functional outcome of tension band wiring with k-wires for olecranon fractures.

2019 ◽  
Vol 26 (08) ◽  
pp. 1256-1260
Author(s):  
Kashif ◽  
Haseeb Hussain ◽  
Ashfaq Ahmed ◽  
Rizwan Akram ◽  
Atiq uz Zaman ◽  
...  

Among orthopedics trauma, the Olecranon fractures are one of the most commonly seen in the emergency room. The cause of such injuries are either fall or road traffic accident. The coronoid process stabilizes the humerus against the distal ulna. There is loss of extensor mechanism at the elbow joint whenever there is fracture of Olecranon. So, its management is always operative. Objectives: The main objective of this study was to determine the functional outcome of patients with olecranon fractures treated with tension band wiring and K-wires. Study Design: Descriptive case Series. Setting: Department of Orthopedics and Spine centre, Ghurki Trust teaching Hospital, Lahore. Period: 25th March 2016 to 30th September 2016. Materials and Methods: 85 patients were selected using Non Probability/ Consecutive sampling technique. Informed consent was taken and demographic information was noted. Surgery was performed by single team of orthopedics surgeons. Patient was followed after 06 weeks. Post-operatively for the assessment of functional outcome in terms of very good to good, fair and poor according to Murphy’s system. All the collected data was entered and analyzed on SPSS version 20. Results: In our study the mean age of the patients was 36.62±14.09 years, the male to female ratio of the patients was 0.7:1. The mean value of total Murphy’s score of the patients was 5.98±2.03. In this study the good functional outcome was observed in 35(41.18%) patients, fair outcome was observed in 46(54.12%) patients. Conclusion: The tension band wiring with K-wires shows good and satisfactory functional outcome for the management of olecranon fractures.

Author(s):  
Pankaj Spolia ◽  
Abdul Ghani ◽  
Sakib Arfee

<p class="abstract"><strong>Background: </strong>Tension band wiring is the most common operative technique for the internal fixation of olecranon fractures. Stable internal fixation with figure of eight tension band wiring used for simple transverse fractures allows early range of motion, minimize stiffness and gives good results. The aim of this study is to evaluate the functional outcome of simple transverse fractures managed by tension band wiring.</p><p class="abstract"><strong>Methods:</strong> This was an observational prospective study of 24 patients with Mayo type IIA fractures aged between 18 to 65 years, with mean age of 42.5 years treated by tension band wiring. Functional outcome was assessed with Mayo Elbow Performance Score (MEPS) and Visual Analogue Scale (VAS) subjective pain score.</p><p class="abstract"><strong>Results: </strong>Our study was conducted on 24 patients with Mayo type IIA, out of which 16 were males and 8 were females. Most common mode of injury was fall from standing height (75%), followed by road traffic accident (16.7%) and assault (8.3%). The age range was between 18 to 65 years, with mean age of 42.5 years.</p><p class="abstract"><strong>Conclusions:</strong> Tension band wiring is an effective method for the treatment of transverse, non-comminuted and unstable fractures of the olecranon which provides stable fixation, early rehabilitation and gives excellent results when done in expert hands.</p>


Author(s):  
Ashutosh Parate ◽  
Vasant Gawande ◽  
Suvarn Gupta ◽  
Ankit Jaiwal ◽  
Ashwin Chavan ◽  
...  

Introduction: Olecranon fracture are some of the common injuries seen in emergency with commonest mode of trauma being fall on outstretched hand and road traffic accident. Methods: This prospective comparative study was carried out from May 2020 to May 2021 within a study period of 1 year in Datta Meghe Medical College. 20 patients of olecranon fractures were enrolled randomly. Results: According to the Mayo classification, the majority of the cases in our study were type II A fractures. The Mayo elbow performance score. In the K wire category, 5 patients (50%) had excellent results, 3 patients (30%) had decent results, and 2 patients (20%) had fair results. In both categories, there were no negative repercussions. In the cancellous screw category, excellent results were found in 8 patients (80%), nice in 1 patient (10%), and fair in 1 patient (10%). Conclusions: From this study, we came to the conclusion that for displaced olecranon fractures as per Mayo’s II A classification fixed by using cancellous screw with tension band wiring gives better clinical outcome When compared to tension band wiring, K-wire fixation keeps costs down, time, and the chance of implant removal complications.


Author(s):  
Lokesh Kumar Yogi ◽  
Gagandeep Mahi ◽  
C. R. Thorat ◽  
Moti Janardhan Naik

<p><strong>Background:</strong> Fractures of olecranon are common fractures in upper limb. Tension band wiring (TBW) and plate fixation (PF) are mostly used techniques but choice is based on type of fracture and surgeon’s preference.</p><p><strong>Methods:</strong>  A study assessed functional results in 28 patients that were enrolled after the clinical event of trauma has occurred. Patients were divided into two groups- Group (A) for TBW and Group (B) for PF; here gender, age and side of fracture were ignored. Post-operative functional outcome were evaluated by using the Mayo Elbow Performance (MEP) and the Disabilities of the Arm, Shoulder and Hand (DASH) score parameters.</p><p><strong>Results:<em> </em></strong>Mean (SD) union time as determined by postoperative radiographs was 8.5 (1.48) weeks for group (A) and 9 (2.08) weeks for group (B). Mean (SD) MEP score at 9 months in group (A) 84.28 (7.28) and 80.71 (10.92) in group (B). Mean (SD) DASH at 9 months in group (A) 12.2 (8.8) and 11.7 (10.4) in group (B). Complications were reported in group (A) 6 patient (42.85%) out of 14 patients and in group (B) 1 patient (7.14%) out of 14 patients.</p><p><strong>Conclusions:<em> </em></strong>The current study shows that there are no significant differences in functional outcome between both the study groups. Due to lesser complications, we recommend the plate fixation approach as the better choice for transverse displaced olecranon fractures. More large scale studies are required to further confirm our results.</p>


Author(s):  
Krishnaprasad H. S. ◽  
Shivanna Shivanna

<p class="abstract"><strong>Background:</strong> Olecranon fractures are commonly seen injuries in the emergency room. The surgical management of displaced fractures is open reduction and internal fixation with k-wires and figure of eight tension band wiring. It can also be fixed with intramedullary cancellous screw with tension band wiring. The present study is to compare the results of both the surgical procedures and to assess the merits and demerits.</p><p class="abstract"><strong>Methods:</strong> This prospective comparative study was carried out from August 2012 to November 2013 in Bapuji Hospital and Chigateri General Hospital attached to J.J.M Medical College, Davangere, India, where among 20 olecranon fractures, ten were treated with Tension band wiring with Kirshner wire and another ten treated with intramedullary cacellous screw with tension band wiring and the results were evaluated and compared.<strong></strong></p><p class="abstract"><strong>Results:</strong> In our study, most of the cases were type II B fractures according to Colton’s classification. According to Mayo elbow performance score, Excellent  results found  in 8  patients (80%), good in1patient (10%)  and fair in 1 patient (10%) in cancellous screw group and in K wire group, 5 patient (50%) had excellent, 3 patient (30%) had good  and 2 patients (20%) had fair results. No poor result was seen in both groups.</p><p><strong>Conclusions:</strong> From this study it is concluded that using cancellous screw with tension band wiring for displaced transverse and oblique olecranon fractures gives better clinical results when compared to tension band wiring with K-wire fixation avoiding cost, work time loss and possible complications from hard ware removal.</p>


2021 ◽  
Vol 29 (3) ◽  
pp. 230949902110592
Author(s):  
Haruhiko Shimura ◽  
Akimoto Nimura ◽  
Koji Fujita ◽  
Hidetoshi Kaburagi

Background This retrospective study was conducted to assess the clinical outcome and complications between tension band wiring (TBW) with eyelet wire and locking plate fixation used for the treatment of displaced olecranon fractures. Methods A total of 58 patients (36 males and 22 females; mean age: 63 years) were reviewed between April 2014 and September 2020. TBW with Ring Pin (RP group) was applied in 24 patients, including 15 Mayo type ⅡA and 9 Mayo type ⅡB patients. Anatomical locking plate (ALP group) was used in 34 patients, including 22 Mayo type ⅡA and 12 Mayo type ⅡB patients. Clinical outcome was evaluated using the Mayo Elbow Performance Score (MEPS), and active range of motion of the elbow and forearm and postoperative complications were reviewed. Results General characteristic of the patients and the fracture type were similar in the two groups. The mean MEPS values were 96.5 ± 7.3 in the RP group and 94.9 ± 9.4 in the ALP group. The mean elbow flexion arc was 127°±11 in the RP group. The mean elbow flexion arc was 122°±18 in the ALP group. No significant differences in clinical outcomes were observed between the two groups. Complication rates were significantly higher in the ALP group (19/34: 56%) than in the RP group (6/24: 25%). Conclusion Although there were no statistically significant differences in clinical outcomes between the two groups, the ALP group had a higher proportion of any complication than the RP group.


Author(s):  
Maxi Benita Tengler ◽  
Helmut Lill ◽  
Maike Wente ◽  
Alexander Ellwein

Abstract Background Tension band wiring is the standard procedure for patellar fractures, but is associated with a high rate of implant related complications and implant failure. Tension band wiring may fail, especially with multifragmentary and comminuted fractures. Plate fixation of complex patellar fractures seems to be superior to wiring, both clinically and biomechanically. The aim of this study was to evaluate complications after locking plate fixation in patellar fractures two years after surgery and to access the functional outcome. Material and Methods As part of a prospective case series, all patients who had received locking plate fixation of a patellar fracture between April 2013 and May 2018 were clinically examined two years postoperatively and potential complications were evaluated. Results A total of 38 patients aged 19 – 87 years were included. Complications occurred in a total of five patients (13%), including one reactive prepatellar bursitis, one chronic infection and loss of reduction due to a dislocated pole fragment in three cases. The average active range of motion of the affected knee joint two years postoperatively was 133°. The Tegner activity scale score reached 3 points, the Lysholm score 95 points and the Kujala score 95 points. Conclusion With an overall relatively low complication rate and good clinical outcome, dislocated distal pole fragments are a common complication after plate fixation of patellar fractures. If preoperative diagnostic testing shows a pole fragment, a modified hook-plate can be used, with the possibility of fixing the pole fragment.


Author(s):  
Deepak Aher ◽  
Ajay Dandotiya ◽  
Dharmendra Raghuvanshi ◽  
Abhishek Pathak

<p class="abstract"><strong>Background:</strong> Treatment of patellar fractures depends on its type, integrity of extensor mechanism and fragments size. Operative measures are tension band wiring and partial or total patellectomy. Early weight bearing and then gradual mobilization and finally quadriceps strengthening remains the crux of physiotherapy. Aim of this study was to see for the effect of intraoperative mobilisation of knee on functional outcome of tension band wiring in patella fractures.</p><p class="abstract"><strong>Methods:</strong> 30 patients were included in this study from January 2016 to February 2018. Tension band wiring was performed in all the patients. Intraoperative mobilisation of knee as allowed was done when patient was under effect of anesthesia. Final functional outcome was assessed as per the modified knee-rating scale of the Hospital for Special Surgery and also range of motion noted. Patients were evaluated at 1 month, 2 month, 6 month and 12 months.<strong></strong></p><p class="abstract"><strong>Results:</strong> Patients aged from 25-65 years with mean age of 40 years. 26 patients were male and 4 female. In 20 cases, Right knee was involved. All had trauma due to road traffic accident. Mean operation time was 1 hour. At the end of 1 year follow up only 2 patients had range of motion &lt;90, 4 patients had range of motion 90-120 degrees and 24 patients had range of motion &gt;120 degrees. After 1 year, functional outcome was, excellent in 24, good in 4, fair in 1 and poor in 1.</p><p class="abstract"><strong>Conclusions:</strong> Intraoperative mobilisation of knee after a stable fixation with tension band wiring of patella can prove to a very effective method for increasing postoperative range of motion and improving functional outcome.</p>


2011 ◽  
Vol 23 (01) ◽  
pp. 83-87 ◽  
Author(s):  
Chien-Chung Kuo ◽  
Horng-Chaung Hsu ◽  
Shih-Wun Hong ◽  
Tung-Wu Lu

Tension-band wiring is the preferred method of treatment for olecranon fractures and is widely used throughout the world. This technique simply and effectively transforms the forces produced by the pulling of the triceps into forces causing compression of the fracture. Although the procedure is associated with a high union rate, the incidence of skin complications is also high. The most frequent complication is symptomatic prominence of the Kirschner wires (K-wires). The purpose of this retrospective study was to identify the optimal fixation of tension-band wiring in the treatment of olecranon fractures using biomechanical techniques. Sixty-two patients were divided into two groups: a bicortical Kirschner wire group and an intramedullary K-wire group. The migration rate of the K-wires and the union rate of fractured bone were measured in both groups. Achievement of radiographic union was similar in the two groups. However, the K-wire migration rate was higher in the intramedullary K-wire group than in the bicortical K-wire group. With appropriate surgical technique, the use of bicortical K-wires is biomechanically superior to the use of intramedullary K-wires in the treatment of olecranon fractures.


Sign in / Sign up

Export Citation Format

Share Document