MONITORING OF FUNGAL AEROSOLS IN SOME EDUCATIONAL BUILDINGS FROM IASI, ROMANIA

2016 ◽  
Vol 15 (4) ◽  
pp. 801-807
Author(s):  
Florin Daniel Lipsa ◽  
Eugen Ulea ◽  
Irina Paraschiva Chiriac
2021 ◽  
Vol 13 (12) ◽  
pp. 6875
Author(s):  
Irene Poza-Casado ◽  
Raquel Gil-Valverde ◽  
Alberto Meiss ◽  
Miguel Ángel Padilla-Marcos

Indoor air quality (IAQ) in educational buildings is a key element of the students’ well-being and academic performance. Window-opening behavior and air infiltration, generally used as the sole ventilation sources in existing educational buildings, often lead to unhealthy levels of indoor pollutants and energy waste. This paper evaluates the conditions of natural ventilation in classrooms in order to study how climate conditions affect energy waste. For that purpose, the impact of the air infiltration both on the IAQ and on the efficiency of the ventilation was evaluated in two university classrooms with natural ventilation in the Continental area of Spain. The research methodology was based on site sensors to analyze IAQ parameters such as CO2, Total Volatile Organic Compounds (TVOC), Particulate Matter (PM), and other climate parameters for a week during the cold season. Airtightness was then assessed within the classrooms and the close built environment by means of pressurization tests, and infiltration rates were estimated. The obtained results were used to set up a Computational Fluid Dynamics (CFD) model to evaluate the age of the local air and the ventilation efficiency value. The results revealed that ventilation cannot rely only on air infiltration, and, therefore, specific controlled ventilation strategies should be implemented to improve IAQ and to avoid excessive energy loss.


2021 ◽  
pp. 102405
Author(s):  
Amirhossein Fathi ◽  
Mohammad Salehi ◽  
Mohsen Mohammadi ◽  
Yasmin Rahimof ◽  
Parisa Hajaligol

2021 ◽  
Vol 20 (3/4) ◽  
pp. 363
Author(s):  
G. Sasikala ◽  
B. Roopesh ◽  
S.V. Charan Sai ◽  
Y. Sathish Kumar

Energies ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4734 ◽  
Author(s):  
Jing Zhao ◽  
Yahui Du

An educational building is a kind of public building with a high density of occupants and high energy consumption. Energy-saving technology utilization is an effective measure to achieve high-performance buildings. However, numerous studies are greatly limited to practical application due to their strong regional pertinence and technical simplicity. This paper aims to further optimize various commonly used technologies on the basis of the current national standards, and to individually establish four recommended technology selection systems corresponding to four major climatic regions for realizing nearly zero energy educational buildings (nZEEBs) in China. An educational building was selected as the case study. An evaluation index of energy-saving contribution rate (ECR) was proposed for measuring the energy efficiency of each technology. Thereafter, high energy efficiency technologies were selected and implemented together in the four basic cases representing different climatic regions. The results showed that the total energy-saving rate in severe cold regions increased by 70.74% compared with current national standards, and about 60% of the total energy-saving rate can be improved in cold regions. However, to realize nZEEBs in hot summer and cold winter regions as well as in hot summer and warm winter regions, photovoltaic (PV) technology needs to be further supplemented.


Author(s):  
Ibrahim Al-Sulaihi ◽  
Khalid Al-Gahtani ◽  
Abdullah Alsugair ◽  
Ibrahim Tijani

2020 ◽  
Vol 24 (1) ◽  
pp. 357-367
Author(s):  
Liva Asere ◽  
Andra Blumberga

AbstractThe energy efficiency – indoor air quality dilemma is well known and the main drawback to operate the mechanical ventilation is electricity costs as concluded from previous studies. Educational buildings are one of the places where future taxpayers spend a lot of time. This paper aims to study an alternative solution on how to reduce energy efficiency – indoor air quality dilemma in educational buildings by adopting systems that use renewable energy sources. A typical education building in Latvia is taken as a case study by changing it from a consumer to prosumer. This building type has a specific electricity usage profile that makes the choice of photovoltaics (PV) power quite challenging so the various power options have been analysed and used for an electricity solution. Also, the more decentralised preference is chosen – disconnect from a public heating provider and using a local system with a pellet boiler. Educational buildings using PV can reduce the electricity tariff, but the payback periods are still not very satisfactory without subsidies. The average electricity tariff per month varies between scenarios and the best one is for the scenario with 30 kW installed power. The educational building partly using 16 kW PV system reduces not only its bill for electricity but also reduces CO2 emissions by around 36 tons. The education buildings as energy prosumers using renewable energy sources are reducing GHG emissions by having high indoor air quality.


2021 ◽  
Vol 9 ◽  
Author(s):  
Giulia Ulpiani ◽  
Negin Nazarian ◽  
Fuyu Zhang ◽  
Christopher J. Pettit

Maintaining indoor environmental (IEQ) quality is a key priority in educational buildings. However, most studies rely on outdoor measurements or evaluate limited spatial coverage and time periods that focus on standard occupancy and environmental conditions which makes it hard to establish causality and resilience limits. To address this, a fine-grained, low-cost, multi-parameter IOT sensor network was deployed to fully depict the spatial heterogeneity and temporal variability of environmental quality in an educational building in Sydney. The building was particularly selected as it represents a multi-use university facility that relies on passive ventilation strategies, and therefore suitable for establishing a living lab for integrating innovative IoT sensing technologies. IEQ analyses focused on 15 months of measurements, spanning standard occupancy of the building as well as the Black Summer bushfires in 2019, and the COVID-19 lockdown. The role of room characteristics, room use, season, weather extremes, and occupancy levels were disclosed via statistical analysis including mutual information analysis of linear and non-linear correlations and used to generate site-specific re-design guidelines. Overall, we found that 1) passive ventilation systems based on manual interventions are most likely associated with sub-optimum environmental quality and extreme variability linked to occupancy patterns, 2) normally closed environments tend to get very unhealthy under periods of extreme pollution and intermittent/protracted disuse, 3) the elevation and floor level in addition to room use were found to be significant conditional variables in determining heat and pollutants accumulation, presumably due to the synergy between local sources and vertical transport mechanisms. Most IEQ inefficiencies and health threats could be likely mitigated by implementing automated controls and smart logics to maintain adequate cross ventilation, prioritizing building airtightness improvement, and appropriate filtration techniques. This study supports the need for continuous and capillary monitoring of different occupied spaces in educational buildings to compensate for less perceivable threats, identify the room for improvement, and move towards healthy and future-proof learning environments.


2018 ◽  
Vol 17 (1) ◽  
pp. 47-51
Author(s):  
Fabio Casciati ◽  
Sara Casciati

Sign in / Sign up

Export Citation Format

Share Document