scholarly journals HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC PROCEDURE FOR THE QUANTITATIVE ESTIMATION OF TANNIC ACID IN ROOTS OF Chlorophytum borivilianum

1989 ◽  
Vol 35 (12) ◽  
pp. 2285-2289 ◽  
Author(s):  
B E Cham ◽  
H P Roeser ◽  
T W Kamst

Abstract We describe a high-performance liquid chromatographic procedure for the simultaneous measurement of vitamins K1 and E in human serum. Delipidated human serum (free of vitamins K1 and E) was used to make standard solutions of these vitamins, and cetyl naphthoate and alpha-tocopheryl acetate were the internal standards for vitamin K1 and vitamin E, respectively. A simple, novel separation method utilizing liquid-liquid partition chromatography was used as a preparative "clean-up" procedure. Cetyl naphthoate and vitamin K1 (after post-column reduction) were detected by fluorescence, alpha-tocopheryl acetate and vitamin E by ultraviolet absorption. Sensitivity (detection limit) of the assay was 30 pg for vitamin K1 and 5 ng for vitamin E per injection. The method is specific, precise, and more rapid than previously described procedures. Within- and between-assay CVs were 8.1% and 12.9%, respectively, for vitamin K1; 3.5% and 6.0%, respectively, for vitamin E. Analytical recoveries of vitamins K1 and E were 80% and 93%, respectively, from serum and from delipidated serum (standards). The average neonatal serum concentration of vitamin K1 was 83 ng/L, 2.5 mg/L for vitamin E; for normolipidemic adults, the values were 343 ng/L and 7.9 mg/L, respectively, and for hyperlipidemic adults, 541 ng/L and 11.1 mg/L, respectively.


1982 ◽  
Vol 65 (6) ◽  
pp. 1388-1394 ◽  
Author(s):  
Roger C Snyder ◽  
William C Brumley ◽  
Charles V Breder ◽  
Thomas Fazio

Abstract The confirmation of 2,4- and 2,6-toluenediamine (TDA) in aqueous extracts from boil-in-bags and retortable pouches is described. The extracts were initially analyzed by a high performance liquid chromatographic procedure and any apparent 2,4- and/or 2,6-TDA were quantitated. The liquid chromatographic effluent corresponding to any apparent 2,4- or 2,6-TDA was collected. TDA was then partitioned into ethyl acetate and reacted with trifluoroacetic anhydride (TFAA). The TDA-TFAA derivative formed was confirmed by gas-liquid chromatography (GLC) using a 1.2 m × 0.32 cm nickel column packed with 6% OV-17 on Superpak-20M. Results obtained from analyzing extracts of several retortable pouches and boil-in-bags showed levels of TDA migration ranging from <0.1 to 2.2 ppb (μg/L). Additional confirmation of the TDA-TFAA derivative from retortable pouches by multiple ion detection GC/mass spectrometry is also described.


1986 ◽  
Vol 32 (6) ◽  
pp. 1004-1006 ◽  
Author(s):  
D J VanderJagt ◽  
P J Garry ◽  
W C Hunt

Abstract Ascorbic acid was measured in 125 plasma samples by an automated colorimetric method involving dichlorophenolindophenol and by a "high-performance" liquid-chromatographic procedure with electrochemical detection. The two methods gave comparable results for samples with ascorbate concentrations of 1 to 20 mg/L (r = 0.97). We also measured the amount of total ascorbate (ascorbic acid + dehydroascorbic acid) in the same samples by a liquid-chromatographic procedure with precolumn derivitization of ascorbic acid. We confirmed that plasma contains little dehydroascorbic acid.


1982 ◽  
Vol 65 (3) ◽  
pp. 753-756
Author(s):  
Walter F Schmidt

Abstract A high performance liquid chromatographic procedure has been developed for the assay of phenprocoumon in tablets. In comparison to the present official USP assay procedure, it is equivalent in precision and accuracy and is faster and more specific. A mobile phase consisting of a 1% solution of acetic acid in acetonitrile-water (4 + 3) separates phenprocoumon from warfarin internal standard on a 6 μm octadecylsilane (ODS) column with UV detection at 311 nm. The method enables the concurrent determination of phenprocoumon and possible contaminants such as salicylic acid.


Sign in / Sign up

Export Citation Format

Share Document