Calculations of Body Exposure from Percutaneous Absorption Data

1989 ◽  
Vol 8 (5) ◽  
pp. 815-827 ◽  
Author(s):  
C. A. Franklin ◽  
D. A. Somers ◽  
I. Chu

Assessment of risks to humans associated with the use of chemicals requires knowledge of the hazard (toxicity) of the chemical and level of human exposure. Hazard assessment is often based on animal bioassays and quantitative exposure estimates of dermal exposure obtained from studies monitoring workers. Because human skin is an effective barrier to many chemicals, it cannot be assumed that the deposited dose is equivalent to the systemic dose. However, an estimate of systemic dose may be derived by multiplying the deposited dose by the percentage of percutaneous uptake. This correction can have major impact on the regulatory decision, because the adjusted dose used in the risk calculation may be reduced significantly, especially at high doses, when the uptake is not linearly proportional to the exposure. It is therefore important that the dermal absorption value be accurate. As outlined in this paper, numerous factors can affect percutaneous absorption. Nevertheless, many regulatory agencies will consider the use of percutaneous absorption data derived from in vivo studies to adjust the dermally deposited dose to that delivered systemically. Numerous issues must be resolved before in vitro dermal penetration studies can be used for risk assessment.


2021 ◽  
Vol 17 (1) ◽  
Author(s):  
Victoria K. Llewelyn ◽  
Lee Berger ◽  
Beverley D. Glass

An amendment to this paper has been published and can be accessed via the original article.


2021 ◽  
Vol 17 (1) ◽  
Author(s):  
Victoria K. Llewelyn ◽  
Lee Berger ◽  
Beverley D. Glass

Abstract Background Infectious disease, particularly the fungal disease chytridiomycosis (caused by Batrachochytrium dendrobatidis), is a primary cause of amphibian declines and extinctions worldwide. The transdermal route, although offering a simple option for drug administration in frogs, is complicated by the lack of knowledge regarding percutaneous absorption kinetics. This study builds on our previous studies in frogs, to formulate and predict the percutaneous absorption of a drug for the treatment of infectious disease in frogs. Chloramphenicol, a drug with reported efficacy in the treatment of infectious disease including Batrachochytrium dendrobatidis, was formulated with 20% v/v propylene glycol and applied to the ventral pelvis of Rhinella marina for up to 6 h. Serum samples were taken during and up to 18 h following exposure, quantified for chloramphenicol content, and pharmacokinetic parameters were estimated using non-compartmental analysis. Results Serum levels of chloramphenicol reached the minimum inhibitory concentration (MIC; 12.5 μg.mL− 1) for Batrachochytrium dendrobatidis within 90–120 min of exposure commencing, and remained above the MIC for the remaining exposure time. Cmax (17.09 ± 2.81 μg.mL− 1) was reached at 2 h, while elimination was long (t1/2 = 18.68 h). Conclusions The model, based on in vitro data and adjusted for formulation components and in vivo data, was effective in predicting chloramphenicol flux to ensure the MIC for Batrachochytrium dendrobatidis was reached, with serum levels being well above the MICs for other common bacterial pathogens in frogs. Chloramphenicol’s extended elimination means that a 6-h bath may be adequate to maintain serum levels for up to 24 h. We suggest trialling a reduction of the currently-recommended continuous (23 h/day for 21–35 days) chloramphenicol bathing for chytrid infection with this formulation.


Author(s):  
R.F. Egerton

SIGMAL is a short (∼ 100-line) Fortran program designed to rapidly compute cross-sections for L-shell ionization, particularly the partial crosssections required in quantitative electron energy-loss microanalysis. The program is based on a hydrogenic model, the L1 and L23 subshells being represented by scaled Coulombic wave functions, which allows the generalized oscillator strength (GOS) to be expressed analytically. In this basic form, the model predicts too large a cross-section at energies near to the ionization edge (see Fig. 1), due mainly to the fact that the screening effect of the atomic electrons is assumed constant over the L-shell region. This can be remedied by applying an energy-dependent correction to the GOS or to the effective nuclear charge, resulting in much closer agreement with experimental X-ray absorption data and with more sophisticated calculations (see Fig. 1 ).


1973 ◽  
Vol 35 (4) ◽  
pp. 472-476 ◽  
Author(s):  
Shuhei SHIMAO ◽  
Yasuyuki SHIMIZU ◽  
Motoyuki MIHARA ◽  
Toshiaki USUI ◽  
Hiroko KAWAMOTO

Author(s):  
Ching-Lang Chiang ◽  
Neeraj Khurana ◽  
Daniel T. Hurley ◽  
Ken Teasdale

Abstract Backside emission microscopy on heavily doped substrate materials was analyzed from the viewpoint of optical absorption by the substrate and sample preparation technique. Although it was widely believed that silicon is transparent to infrared (IR) radiation, we demonstrated by using published absorption data that silicon with doping levels above 5 x 1018cm-3 is virtually opaque, leaving only a narrow transmission window around the energy bandgap. Because the transmission depends exponentially on the thickness of die, thinning to below 100µm is shown to be required. Even an advanced IR sensor such as HgCdTe would find little light to detect without thinning the die. For imaging the circuit, an IR laser-based system produced poor images in which the diffraction patterns often ruined the contrast and obscured the image. Hence, a precise, controlled die thinning technique is required both for emission detection and backside imaging. A thinning and polishing technique was briefly described that was believed to be applicable to most ceramic packages. A software technique was employed to solve the image quality problem commonly encountered in backside imaging applications using traditional microscope light source and a scientific grade CCD camera. Finally, we showed the impact of die thickness on imaging circuits on a heavily doped n type substrate.